MICRO ~ flex FLEXIBLE AC Current Probes ACP 1000 SERIES Accurate, Thin and Flexible Three selectable current ranges 10/100/1000A 3 Standard conductor diameters 50/70/100mm Easy to insert probe in confined spaces Multimeter and Oscilloscope versions Wide dynamic range 100mA to 1000A AC RMS 1000V, CAT III, Pollution degree 2 Excellent response to rapid current changes External power supply option (ACP 1005 only) Compact lightweight design No magnetic hysteresis, saturation or non linearity High Accuracy and Wide Dynamic Range Advanced coupling design results in minimal effect of external magnetic fields and off-centre conductor positioning on probe accuracy. EN 61010-2-032:2002 and EMC Conformance Safety features provide the user with confidence when making measurements in hazardous voltage areas. Conformance to EMC standards ensures high reliability through reduced susceptibility to electromagnetic interference. TYPICAL APPLICATIONS o Connection to most measuring instruments including multimeters, oscilloscopes or recording devices o Development and servicing of power electronic equipment o Analysis of complex current o Analysis of harmonics, power measurements, measurement of peak loads in mains and in UPS. ACP 1000 MICROflex RANGE 120731 03 S P E C I F I C A T I O N S NON-INVASIVE AC CURRENT MEASUREMENT NON-INVASIVE AC CURRENT MEASUREMENT MODEL ACP 1000 ACP 1005 MODEL ACP 1000 ACP 1005 Current Ranges (RMS) 10 / 100 / 1000A Output Sensitivity 100mV / 10mV / 1mV / A Noise (AC rms) 0.1A (10A/100A range), 1A (1000A range) Linearity 0.2% of reading Basic Accuracy 1% of reading 0.1A (10/100A) / 1A (1000A range) Conductor position sensitivity 2.5% of reading Frequency Range (-2dB) 20Hz to 20kHz 20Hz to 100kHz Phase shift (45 65Hz) <1 degree Load Impedance > 100 kOhms Output connection 0.5m lead terminated with 4mm 0.5m coax terminated with safety safety plugs male BNC connector ENVIRONMENTAL DATA SAFETY EN61010-2-032:2002, Operating Temperature -20C to +65C (-4F to 149F) EN 61010-031:2002 EN 61010-1:2001 1000V, Measurement Category III, Pollution Degree 2. Temperature Coefficient 0.15% of reading per C EMC Standard EN 61326-2-2:2006 ( 0.1% of reading per F) Storage Temperature -40C to +75C(-40F to 167F) MAXIMUM SAFE VOLTAGES (without battery) 1000V AC RMS or DC 30V maximum between output and earth POWER SUPPLY Battery type 2 x AA MN 1500 LR6 Alkaline Battery life 1000 hrs ACP 1000 All accuracies stated at 23C 1C (73.4F 1.8F) 150 hrs (ACP 1005) External Power Supply 3V / 100mA (ACP 1005 only) MECHANICAL DATA Dimensions (mm) 110 (H) x 65 (W) x 23 (D) DEGREE OF PROTECTION Probe cable diameter 6mm Cable length 2m (Probe to Integrator) IP50 PROBE IP40 Integrator Probe Conductor Part Nos MODEL Diameters 50mm (2), 70mm (3) and P-06.600.6 ACP 1000/2 100mm (4) P-06.600.7 ACP 1000/3 P-06.600.8 ACP 1000/4 GMC-I PROSyS Ltd. offer a wide range of GMC-I PROSyS Ltd. offer a wide range of P-06.600.9 ACP 1005/2 nnoonn--iinnvvaassiivvee PPrroobbeess aanndd CCllaammpp MMeetteerrss ffoorr tthhee P-06.601.0 ACP 1005/3 mmeeaassuurreemmeenntt aanndd aannaallyyss iiss ooff CCuurrrreenntt aanndd VVoollttaaggee P-06.601.1 ACP 1005/4 ACP 1000 MICROflex RANGE 120731 03