Thru-Door Voltage Indicator Flashing and Non-Flashing Product Data Sheet Catalog Numbers R-3W / R-3W-SR SafeSide thru-door voltage indicators provide electrical Voltage Indicator safety information while the panel doors are safely closed. with Solid-on LEDs or Flashing LEDs This one-size-fits-all solution detects 3-phase AC or DC FEATURES: voltage from 40-750VAC/30-1000VDC. The encapsulated Redundant Circuitry / Long Life LED s construction and redundant circuit design means rugged 40-750VAC / 30-1000VDC / 35-600VAC 1 reliability. SafeSide products are available with flashing Potted Construction with 6 Leads LEDs (R-3W) and non-flashing LEDs (R-3W-SR). Phase Insensitive 30mm Pushbutton or Pilot Hole UL TYPE 4X Safer Lock-Out Tag-Out (LOTO) High Surge Immunity L US C UL Listed, Type 4X, 12, 13 Keeping personnel away from live voltage is foundational to LISTED IND. CONT. EQ. electrical safety. Electrical safety demands a precise answer 496Y APPLICATIONS: UL File: E256847 to the question Is voltage present . Thru-door voltage Circuit Breaker Disconnects - No Visible Blades RoHS indicators provide visibility of voltage from outside the High Energy Panels (NFPA 70E Category 3 or 4 Frequently Accessed Panels enclosure without exposing personnel to voltage. Mechanical LOTO: Indicating Zero Energy Panels with Multiple Power Sources More Productivity in Mechanical LOTO Workers performing mechanical LOTO must isolate Three Phase 40-750VAC/30-1000VDC UL-Listed Voltage electrical energy. An externally-mounted voltage detector Indicator for Type 4X/12/13 for 30mm Mounting provides a means to check voltage inside an electrical R-3W Flashing panel. Without a voltage indicator, a mechanic performing 1 mechanical LOTO would be required to work in tandem with R-3W-KB Flush Mount Assembly with Bezel and R-3W (UL) an electrician using a voltmeter to physically verify voltage Adhesive-Backed Warning Label inside an electrical panel. In this case, the electrician is R-3W-L (slips over installed R-3W) exposed to voltage. With thru-door voltage detectors, the Adhesive-Backed Warning Label mechanic can verify zero electrical energy without any R-3W-KB-L (slips over installed R-3W-KB) exposure to voltage. 2 R-3W-SR Non-Flashing Reduced Voltage Exposure and Arc Flash Risk 1 R-3W-SR-KB Flush Mount Assembly with Bezel and R-3W-SR (UL) Voltage is the common denominator in an electrical accident or an arc flash no voltage means no accident, no arc flash. Adhesive-Backed Warning Label R-3W-SR-L (slips over installed R-3W-SR) While performing electrical LOTO with a thru-door voltage detector installed, the electrician can pre-check the internal Adhesive-Backed Warning Label R-3W-KB-L (slips over installed R-3W-SR-KB) voltage state without opening the enclosure. Next, the electrician should replicate a zero voltage reading with his voltmeter as per NFPA 70e 120.1(5). This low-cost, Hazardous Location Flashing Voltage Indicator (Suitable for 3 R-3W2 use in Class 1, Division 2 (Zone 2), Groups A, B, C, D hazardous redundant voltage-verification task reduces arc flash risk Location, or Non-Hazardous Locations Only) and increases electrical safety for workers. 1 R-3W2-KB Flush Mount Assembly with Bezel and R-3W2 (UL) Adhesive-Backed Warning Label R-3W-L (slips over installed R-3W2) Adhesive-Backed Warning Label R-3W-KB-L (slips over installed R-3W2-KB) Warning: Verify an electrical conductor has been de-energized using an adequately rated (1) Must be purchased as an assembly for UL Listing voltage detector before working on it. Follow appropriate Energy Control (Lockout/Tagout) (2) For the R-3W-SR, the LED appearance for differing voltages as follows: 32-159V(FLASH) procedures as per OSHA Subpart S the current edition of NFPA 70E and the current 160-329V(SHIMMER) 330V+(SOLID)). edition of CSA Z462. (3) See R-3W2 datasheet for specifications and UL information 5001 Tremont Avenue 2014 Grace Engineered Products, Inc. Davenport, IA 52807 Data:R-3W/R-3W-SR:08/2014 LIT-DS-R3W (800) 280-9517 Fax: (563) 386-9639 SafeSide is a Trademark of Grace Engineered Products, Inc. www.pesd.comVoltage Indicator TYPICAL CONFIGURATION*: 1.20 + 0.02 OPERATIONAL RANGE: AC Single or 3-Phase: 40-750V 50/60Hz 30.5mm + 0.5mm VAC VDC Operates up to 400 Hz - - THREE PHASE DELTA, 3W + GND UP TO 1 L2 L3 + + ANTI-ROTATION PANEL 1.102 -0+.012 DC OR STORED ENERGY: 30 to 1000 VDC 1.549 DIA. LOCATIONS POWER 28.00mm -0+.03 KNOCKOUT 39.34mm + + L1 GND MAXIMUM VOLTAGE: 750VAC/1000VDC - Surge 4300V for 5 L1 - - MAIN FUSED DANGER seconds 0.157 FEED SAFETY 4.00mm POWER CONSUMPTION: 1.2 Watts 750 VAC (Approximately) 30mm HEX NUT CUSTOMER PANEL SWITCH L2 TEMPERATURES: Operate: -20C to +55C, Storage: -45C to 1.381 DIA. SLEEVE OR M30X1.5 4G6G EXT +85C O-RING SEAL BREAKER Wire: 18 AWG, FAILURE CURRENT: Maximum single component failure fault current L3 Style 1452, is 3.7mA 750 3-Phase FUSING: Follow all Local, State, and national Electrical Codes when installing this equipment. GROUND RED OR Overcurrent protection of the supply leads may 1.250 YEL 31.75mm ISOLATED be necessary. The installation of overcurrent BLU 1.050 26.67mm GRN protection shall be in accordance with the requirements in the NEC (NFPA 70) or end 3.071 78.00mm product standard(s) when used in the final installation. INDICATOR FLASH RATES for the R-3W only (L1,L2,L3,GND) 3-PHASE LINE-TO-LINE <29 30 120 240 480 600 750 FLASHES/SEC (TYPICAL) 0 1.3 4.2 5.8 7.3 8 8.8 Accessories: DC OR STORED ENERGY (VDC) <27 30 48 110 300 600 1000 FLASHES/SEC (TYPICAL) 0 1.6 2.5 4.5 6.9 8.8 9.1 New Bezel-mount Installation for Voltage Indicator NEW Create a near-flush look by purchasing your Voltage Indicator Part : R-3W-NPT125 with our new bezel. A 30mm to 1 NPT conduit adapter. This assembly fits into a standard conduit LB for Part Number Description mounting on the outside of an enclosure. Flashing Voltage Indicator with Bezel R-3W-KB 2.0 Non-Flashing Voltage Indicator with Bezel R-3W-SR-KB Class 1 Div 2 Voltage Indicator with Bezel R-3W2-KB 4.5 Dimensions of the Bezel - Diameter: 2.25 *Corresponding label available for bezel-mount configurations. Outside cabinet depth: .20 Note: When mounting the Bezel (part numbers with -KB), the Inside cabinet depth: 3.50 diameter of the cut-out is as follows: 1.701 inches (43.21mm). Voltage Indicator Alert Label DANGER VOLTAGE IF FLASHING SAFETY PROCEDURES STILL APPLY. This adhesive-back label fits over an installed power warning alert. TEST BEFORE TOUCHING. Warning language differs for flashing and non-flashing units. Part Number Description GRACE R-3W-L Label for Flashing and Class 1 Div 2 Voltage Indicator ENGINEERED WARNING PRODUCTS, INC WWW.GRACE-ENG.COM Read instructions before installing Part : R-3W-DR-C6 R-3W-SR-L Label for Non-Flashing Voltage Indicator Use this door mount accessory for additional voltage protection. Label dimensions are 3 W x 2.3 H. Label for all Bezel Units R-3W-KB-L Includes a 30mm adapter and 6 of NW10 flexible conduit. (Allow 4.5 depth into panel).