Lifetime Limited Warranty Greenlee Textron Inc. warrants to the original purchaser of these goods for use that these products will be free from defects in workmanship and material for their useful life, excepting normal wear and abuse. This warranty is subject to the same terms and conditions contained in Greenlee Textron Inc.s standard one-year limited warranty. GT-10 Outlet Circuit Tester For all Test Instrument repairs, contact Customer Service at 800-435-0786 and request a Return Authorization. An Approved Authorization including shipping label and instructions will be sent. For items not covered under warranty (such as items dropped, abused, etc.), a repair cost quote is available upon request. Note: Prior to returning any test instrument, please check replaceable batteries or make sure the Electric shock hazard: battery is at full charge. Contact with live circuits could result in severe injury Garanta limitada vlida durante la vida til del producto or death. Greenlee Textron Inc. le garantiza al comprador original de estos bienes de uso, que los mismos estarn libres de defectos de materiales y fabricacin durante su vida til excepto en el caso de que sean maltratados o hayan sufrido el deterioro normal. Esta garanta est sujeta a los mismos trminos y condiciones de la garanta estndar limitada vlida por un ao, otorgada por Typical 3-Wire NEMA 5-15R Receptacle (polarized) Greenlee Textron Inc. Para reparaciones de todo instrumento de verificacin, comunquese con el Departamento de Hot Contact (black wire) Servicio al Cliente al 800-435-0786 y solicite una autorizacin de devolucin. Se le enviar una Neutral Contact (white wire) Autorizacin Aprobada incluyendo una etiqueta de envo e instrucciones. Puede obtener, previa solicitud, una cotizacin de precios de reparacin para aquellos artculos Ground Contact (green or uninsulated wire) que no estn cubiertos bajo esta garanta (los que se han dejado caer o han sido maltratados). INDICATOR FAULT REASON FOR WIRING FAULT Aviso: Antes de devolver un instrumento de verificacin, revise si las pilas estn bajas y es Open Ground Ground contact not connected necesario reemplazarlas. Open Neutral Neutral contact not connected Garantie vie limite Open Hot Hot contact not connected La socit Greenlee Textron Inc. garantit lacheteur dorigine de ces produits que ces derniers Hot / Ground Reverse Hot and ground contacts interchanged ne comportent aucun dfaut dexcution ou de matriau pour la dure de leur vie utile, sauf Hot / Neutral Reverse Hot and neutral contacts interchanged lusure normale. Cette garantie est assujettie aux mmes conditions que celles contenues dans les modalits et conditions de la garantie limite standard dun an de Greenlee Textron Inc. Correct Receptacle is wired correctly Pour toutes les rparations dinstruments de mesure, appeler le service aprs vente au KEY: Indicator Lit Indicator Not Lit 800 435-0786 et demander une autorisation de retour. Une autorisation approuve, incluant une tiquette dexpdition et des instructions sera envoye. Instructions Lorsque les articles ne sont pas protgs par une garantie (comme si lappareil tombe, sil est 1. Unplug all appliances or equipment on the circuit being tested. soumis un usage abusif, etc.), une soumission pour le prix de rparation sera prsente sur demande. 2. Plug the GT-10 into any standard 120 V AC receptacle (NEMA 5-15R). Remarque : Avant de renvoyer un appareil de mesure, vrifier les piles remplaables ou 3. Compare the illuminated lamps on the GT-10 to the code key located sassurer que la pile est charge au complet. on the product or in the table above. Note: If the LEDs indicate anything other than Correct Wiring, have the wiring verified by a qualified electrician. For technical assistance: 800-435-0786 Note: The GT-10 is not a comprehensive diagnostic instrument. The GT-10 is a simple instrument designed to detect nearly all, probable and common, improper wiring conditions. It will not detect a Greenlee / A Textron Company combination of defects. It will not indicate the quality of ground or 4455 Boeing Drive, Rockford, IL 61109-2988 USA reversal of grounded and grounding conductors. It will not detect two Customer Service (International): 815-397-7070 Fax: 815-397-9247 Customer Service (North America): 800-435-0786 hot wires in a circuit. Circuit capacitance may indicate continuity in an USA Fax: 800-451-2632, 815-397-1865 Canada Fax: 800-524-2853 open circuit. Failure to unplug appliances or equipment on the circuit being tested can cause erroneous readings. Greenlee Textron Inc. is a subsidiary of Textron Inc. www.greenlee.com 999 6763.4 REV 1 2005 Greenlee Textron Inc. 7/05Verificador de Circuitos Vrificateur de prise de Tomacorrientes GT-10 de courant GT-10 Peligro de electrocucin: Risques de dcharge lectrique : El contacto con circuitos activados podra ocasionar Un contact avec des circuits sous tension pourrait graves lesiones o incluso la muerte. entraner des blessures graves, voire mortelles. Receptculo NEMA 5-15R trifilar tpico (polarizado) Rceptacle NEMA 5-15R 3 fils type (polaris) Contacto energizado (alambre negro) Contact chaud (fil noir) Contact neutre (fil blanc) Contacto neutro (cable blanco) Contact de mise la terre (vert ou fil non isol) Contacto a tierra (cable verde o sin forro aislante) INDICADOR FALLA RAZN DE LA FALLA DE CABLEADO INDICATEUR DFAUT RAISON DU DFAUT DE CBLAGE Tierra abierta Contacto a tierra no conectado Mise la terre ouverte Contact de mise la terre non branch Neutro abierto Contacto neutro no conectado Ouvert neutre Contact neutre non branch Energizado abierto Contacto energizado no conectado Ouvert chaud Contact chaud non branch Energizado/Tierra invertida Contactos energizado y a tierra intercambiados Chaud / Mise la terre inverse Contacts chaud et de mise la terre remplacs lun par lautre Energizado/Neutro invertido Contactos energizado y neutro intercambiados Chaud / Neutre invers Contacts chaud et neutre remplacs lun par lautre Correcto El receptculo est cableado correctamente Correct Les fils de la prise sont installs correctement LEYENDA: Indicador iluminado Indicador no iluminado RFRENCE : Voyant allum Voyant teint Instrucciones Mode demploi 1. Desenchufe todo aparato o equipo conectado al circuito que se est 1. Dbrancher tous les appareils ou quipements sur le circuit vrifier. verificando. 2. Brancher le GT-10 dans nimporte quelle prise de courant standard 2. Enchufe la unidad GT-10 a cualquier receptculo estndar de (NEMA 5-15R) de 120 V c.a. 120V CA (NEMA 5-15R). 3. Comparer les voyants allums sur le GT-10 au code de cl situ sur le 3. Compare las lmparas iluminadas en la unidad GT-10 con la clave de produit ou dans le tableau ci-dessus. cdigos en el producto o en la tabla que aparece arriba. Remarque : Si les DEL indiquent autre chose que Correct Nota: Si los diodos emisores de luz (LED) indican cualquier otra Wiring (cblage correct), faire vrifier le cblage par un cosa excepto que el cableado es correcto Correct Wiring, lectricien qualifi. contrate a un electricista profesional a fin de que revise el Remarque : Le GT-10 nest pas un instrument de diagnostic complet. cableado. Le GT-10 est un instrument simple, conu pour dtecter presque Nota: La unidad GT-10 no es un instrumento de diagnstico toutes les conditions probables et courantes de cblage incorrect. Il ne exhaustivo. La unidad GT-10 es un simple instrumento que detecta dtecte pas une combinaison de dfauts. Il nindique pas la qualit de casi todas las condiciones de cableado incorrecto comunes posibles. la mise la terre ou linversion des conducteurs mis la terre ou de No detectar una combinacin de defectos. No indicar la calidad de mise la terre. Il ne dtecte pas deux cbles actifs sur un circuit. La las conexiones a la tierra, conexiones a tierra invertidas o conductores capacit du circuit pourrait indiquer la continuit dans un circuit a tierra. No detectar dos cables energizados en un mismo circuito. La ouvert. Le fait de ne pas dbrancher les appareils ou lquipement capacitancia del circuito podra indicar continuidad en un circuito branchs sur le circuit peut produire des lectures errones. abierto. De no desenchufarse todos los aparatos y equipos conectados al circuito que se est verificando, podran ocasionarse lecturas incorrectas.