Product data sheet 20 32 080 0101 Current Sensor HCME 800A-0-00-CDA-T Current Sensor HCME 800A-0-00-CDA-T Part number 20 32 080 0101 Specification Current Sensor HCME 800A-0-00-CDA-T HARTING eCatalogue Product data sheet 20 32 080 0101 Current Sensor HCME 800A-0-00-CDA-T Technical characteristics R Insulation resistance >500,000k IN X Overall accuracy 1% I , T = 25 C PN A Linearity <0.5% L U Offset voltage O 10mV I = 0 A, T = 25 C P A U Offset after I 10mV OOL Pmax U maximum temperature drift of U 1mV/K OT O U thermal gain drift 0,05 %/K outT t Response time r <3s I PN di/dt with optimal coupling >50A/s f Frequency 0 ... 50 kHz T Ambient temperature -25 ... +85 C A T Storage temperature -25 ... +90 C S U Test voltage, effective (50 Hz, 1 min) 3.5 kV Primary - secondary D U Rated voltage 690V B L Clearance distance 22.7mm s K Creepage distance 36.6mm s Tightening torque 3.2 Nm (2x steel screw M4 - Vertical) Material properties Material (hood/housing) Polycarbonate (PC) Material flammability class acc. to UL94 V-0 RoHS compliant ELV status compliant China RoHS e REACH Annex XVII substances Not contained REACH ANNEX XIV substances Not contained REACH SVHC substances Not contained Specifications and approvals EN 50178 Specifications IEC 61373 Page2/3 Creation date2022-01-19 Please note that the data specified here were taken as extracts from the online catalogue. Please refer to the user documentation for the complete and up-to-date information and data. Please also note that the user is responsible for validating functionality, conformity with applicable laws and directives, as well as for the electrical safety in the particular application. HARTING Electric Stiftung & Co. KG Wilhelm-Harting-Strae 1 32339 Espelkamp Germany Phone +49 5772 47-97100 electric HARTING.com www.HARTING.com