JZ-600-Y-CY flexible, number coded, 0,6/1kV, Cu screened meter marking, EMC-preferred type A Technical data Cable structure Properties In accordance to DIN VDE 0262/12.95 and Bare copper, fine wire conductors, Extensively oil resistant, oil-/ chemical DIN VDE 0281 part 13 according to DIN VDE 0295 cl. 5, BS 6360 Resistance - see table Technical Temperature range cl. 5 and IEC 60228 cl. 5 Informations 1) flexing -15 C to +80 C Special PVC core insulation TI2, to PVC self-extinguishing and flame retardant fixed installation -40 C to +90 C DIN VDE 0281 part 1 according to VDE 0482-332-1-2, DIN EN Nominal voltage U /U 0,6/1 kV Black cores with sequential numbering 60332-1-2/ IEC 60332-1 (equivalent 0 Test voltage 4000 V imprinted in white, according to DIN VDE 0472 part 804 test method B) Breakdown voltage min. 8000 V DIN VDE 0293 The materials used in manufacture are Green-yellow earth core in the outer layer cadmium-free and contain no silicone and Insulation resistance (3 cores and above) free from substances harmful to the min. 20 MOhm x km Cores stranded in layers with optimal wetting properties of lacquers Power rating lay-length UV resistant according to DIN VDE 0298 PVC-insulated inner sheath Minimum bending radius flexing 10x cable Braided screen of tinned Cu wires, Note coverage approx. 85% fixed installation 5x cable G = with green-yellow earth core Special PVC outer sheath TM2, to Radiation resistance x = without green-yellow earth core (OZ). 6 DIN VDE 0281 part 1 up to 80x10 cJ/kg (up to 80 Mrad) Further sizes are available upon request. colour black (RAL 9005) Coupling resistance AWG sizes are approximate equivalent with meter marking, change-over in 2011 max. 250 Ohm/km values. The actual cross-section is in mm. 1) cold bending test, impact resistance test unscreened analogue type: at low temperatures, elongation test at low JZ-600, see page A 16 temperatures. Tested according VDE 0473 part 811-1-4, EN 60811-1-4 Application Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. Interference-free transmission of signals and pulses is assured by the high degree of screening. EMC = Electromagnetic compatibility To optimise the EMC features we recommend a large round contact of the copper braiding on both ends. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No. cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx. mm kg / km kg / km mm kg / km kg / km 11464 2 x 0,5 8,5 41,0 129,0 20 11516 2 x 1 9,4 54,0 150,0 17 11465 3 G 0,5 8,8 45,0 150,0 20 11517 3 G 1 9,8 64,0 163,0 17 11466 4 G 0,5 9,6 54,0 170,0 20 11518 4 G 1 10,6 76,0 200,0 17 11467 5 G 0,5 10,2 66,0 199,0 20 11519 5 G 1 11,4 89,0 239,0 17 11469 7 G 0,5 11,1 79,0 235,0 20 11521 7 G 1 12,5 114,0 289,0 17 11472 12 G 0,5 14,0 137,0 320,0 20 11525 12 G 1 15,7 186,0 464,0 17 11475 18 G 0,5 16,2 156,0 428,0 20 11528 18 G 1 18,4 284,0 628,0 17 11478 25 G 0,5 19,1 250,0 503,0 20 11532 25 G 1 21,6 387,0 855,0 17 11489 2 x 0,75 8,8 46,0 143,0 18 11546 2 x 1,5 10,6 64,0 162,0 16 11490 3 G 0,75 9,3 57,0 155,0 18 11547 3 G 1,5 11,1 82,0 187,0 16 11491 4 G 0,75 9,9 63,0 190,0 18 11548 4 G 1,5 11,8 99,0 240,0 16 11492 5 G 0,75 10,8 76,0 228,0 18 11549 5 G 1,5 13,1 123,0 289,0 16 11494 7 G 0,75 11,5 100,0 323,0 18 11551 7 G 1,5 14,2 148,0 383,0 16 11498 12 G 0,75 14,8 175,0 410,0 18 11556 12 G 1,5 18,1 274,0 592,0 16 11501 18 G 0,75 17,1 240,0 560,0 18 11559 18 G 1,5 21,4 386,0 806,0 16 11504 25 G 0,75 20,2 306,0 730,0 18 11563 25 G 1,5 24,9 531,0 1241,0 16 Continuation A 36JZ-600-Y-CY flexible, number coded, 0,6/1kV, Cu screened meter marking, EMC-preferred type Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No. cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx. mm kg / km kg / km mm kg / km kg / km 11574 2 x 2,5 12,1 110,0 272,0 14 11608 3 G 16 23,7 653,0 1395,0 6 11575 3 G 2,5 12,7 148,0 298,0 14 11609 4 G 16 26,1 807,0 1870,0 6 11576 4 G 2,5 13,8 169,0 345,0 14 11610 5 G 16 29,0 940,0 2720,0 6 11577 5 G 2,5 15,1 220,0 427,0 14 11611 7 G 16 31,8 1345,0 3213,0 6 11578 7 G 2,5 16,6 284,0 561,0 14 11612 3 G 25 28,7 920,0 2465,0 4 11580 12 G 2,5 21,3 470,0 857,0 14 11613 4 G 25 31,7 1169,0 2750,0 4 11582 18 G 2,5 25,4 572,0 1355,0 14 11614 5 G 25 35,0 1420,0 3490,0 4 11584 25 G 2,5 29,6 740,0 1995,0 14 11615 7 G 25 38,4 1921,0 4980,0 4 11590 2 x 4 13,8 124,0 306,0 12 11616 3 G 35 31,2 1250,0 3230,0 2 11591 3 G 4 14,4 178,0 391,0 12 11617 4 G 35 34,5 1680,0 4100,0 2 11592 4 G 4 15,7 234,0 527,0 12 11618 5 G 35 38,1 2020,0 4950,0 2 11593 5 G 4 17,3 284,0 700,0 12 11619 3 G 50 36,9 1887,0 4590,0 1 11594 7 G 4 19,0 321,0 920,0 12 11620 4 G 50 40,7 2370,0 5780,0 1 11596 12 G 4 24,4 581,0 1510,0 12 11621 5 G 50 45,2 2880,0 7210,0 1 11597 2 x 6 15,2 176,0 420,0 10 11622 3 G 70 41,8 2516,0 5610,0 2/0 11598 3 G 6 15,9 245,0 629,0 10 11623 4 G 70 46,0 3257,0 7480,0 2/0 11599 4 G 6 17,3 316,0 731,0 10 11624 5 G 70 50,4 4032,0 9390,0 2/0 11600 5 G 6 19,2 442,0 1105,0 10 11625 3 G 95 46,8 3086,0 8585,0 3/0 11601 7 G 6 21,0 530,0 1465,0 10 11626 4 G 95 51,3 4060,0 10220,0 3/0 11602 2 x 10 18,6 260,0 845,0 8 11627 5 G 95 56,4 5244,0 13800,0 3/0 11603 3 G 10 19,7 367,0 1125,0 8 11628 3 G 120 51,9 4176,0 11105,0 4/0 11604 4 G 10 21,5 549,0 1345,0 8 11629 4 G 120 56,4 5231,0 13750,0 4/0 11605 5 G 10 23,7 604,0 1635,0 8 13137 4 G 150 64,3 7760,0 15990,0 300 kcmil 11606 7 G 10 26,0 820,0 2210,0 8 13147 4 G 185 67,5 8104,0 18470,0 350 kcmil 11607 2 x 16 22,4 491,0 1150,0 6 Dimensions and specifications may be changed without prior notice. (RA01) A 37