LL1x10-42-E-CC 1x42 W Constant Current LED driver Open & short circuit protection 42 W 220-240 VAC 50-60 Hz Adjustable and selectable constant current output: 120 (default) to 350 mA Maximum 42 W load High efficiency 0.94 Suitable for Class I luminaires Wide operational range Protected up to 4 kV power network fast transients Connections L N Current setting (p.2) ** Resistor R output I fv Note: open 120 mA * Not suitable for load side switching operation. R 0 350 mA ** Connect load between terminal (+) and (120mA / Iset) for adjusted output currents. Mains Characteristics Life time 60 000h, at TC max (90 % survival rate) Voltage range 198 - 264 VAC DC range 176 - 280 VDC, Connections and Mechanical Data starting voltage > 190 VDC 2 Max mains current at full load 0.18-0.23 A Wire size 0.5 - 1.5 mm Frequency 0 / 50 - 60 Hz Wire type solid core and fine-stranded Maximum driver to LED wire length 5 m Load Output (Non-Isolated) Weight 135 g IP rating IP20 Output current (I-OUT) 120 mA (default) - 350 mA -Accuracy +/- 5 % Conformity -Ripple < +/- 12 % high frequency Max output power 42 W General and safety requirements EN 61347-1 Efficiency, at full load, typical >0.94 Particular safety requirements for d.c. or a.c. supplied U-OUT (abnormal) 400 V electronic controlgear for LED modules, acc. to EN 61347-2-13 max Thermal protection class EN61347, C5e I-OUT 120 mA 140 mA 350 mA Mains current harmonics, acc. to EN 61000-3-2 P-out (max) 42 W 42 W 42 W Limits for Voltage Fluctuations and Flicker, acc to EN 61000-3-3 U-OUT 80 - 350 V 80-300 V 30-120 V Radio Frequency Interference, acc. to EN 55015 0.98 0.98 0.98 Immunity standard, acc. to EN 61547 max 0.94 0.94 0.93 Performance requirements, acc to EN 62384 Compliant with relevant EU directives Operating Conditions and Characteristics ENEC & CE marked Max.temperature at tc point 75 C Ambient temperature range -20+50 C Storage temperature range -40+80 C Maximum relative humidity no condensation Note: See page 2 for dimensions Helvar Data is subject to change without notice. More information at: www.helvar.com T22 028 1B 26.10.2015 1/3 1Load output Output voltage U-OUT 400 U-OUT min 350 U-OUT max 300 250 200 150 100 50 0 120 140 160 180 200 220 240 260 280 300 320 340 350 I-OUT mA Current setting resistor values R () 0 47 120 180 270 330 470 560 680 820 1k 1,2k 1,5k 1,8k 2,2k 2,7k 3,3k 3,9k 4,7k 5,6k 8,2k 12k 22k I out 350 340 330 320 310 300 290 280 270 260 250 240 230 220 210 200 190 180 170 160 150 140 130 120 (mA) Dimensions 21 180 30 190 Quantity of drivers per miniature circuit breaker 16 A Type C Based on I Based on I Typ.inrush 1/2 value Calculated Cont peak current time energy 2 2 (pcs.) (pcs.) I (A) t (s) I t (A s) peak peak 57 62 23 176 0.0672 2 Helvar Data is subject to change without notice. More information at: www.helvar.com T22 028 1B 26.10.2015 2/3 U-OUT V