Model SC500 Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION Unamplified pressure or load The SC series models are self-calibrating microprocessor- Pressure or load with inter nal voltage amplifiers based transducer signal conditioners when used with sig mod Pressure or load with inter nal or exter nal two-wire equipped transducers. Indicators are available with several dif- current amplifiers ferent types of input channels and output channels. When used ac/ac displacement transducer with unamplified strain gage transducers that have the signature dc/dc displacement transducer calibration module installed, these instruments will completely self calibrate zero, span, decimal point, and engineering units Available output channels for the SC500 include: automatically. Contact relays for the two for m C or three for m A optional limits Isolated digital-to-analog voltage (5 Vdc or 0 Vdc to 10 Vdc) Input channels are available for a variety of transducers. Each input channel includes an excitation power supply and either In addition to the physical input and output channels, up to three an isolated voltage (optional) or isolated current analog output virtual channels can be configured to assist in many potential (optional). applications. FEATURES Choice of transducer inputs Small 1/8 DIN for m factor Automatic setup, calibration via sig cal Shunt-cal, mV/V or known load calibration Peak/valley capture Optional analog output and RS-232/RS-485 Field selectable frequency response (up to 250 Hz) and calibration Up to three vir tual channels (optional) CE approvedModel SC500 Phy SICAl SPECIFICATIONS COMMUNICATIONS OUTPUT (OPTIONAl) SPECIFICATIONS Characteristic Measure For m factor 1/8 DIN Characteristic Measure Case material Aluminum Serial setup and output Isolated RS-232 or RS-485 (factory option) Max. baud rate 38400 Baud ENvIRONMENTAl SPECIFICATIONS Characteristic Measure lIMITS OUTPUT (OPTIONAl) SPECIFICATIONS Temperature, operating 5 C to 40 C 40 F to 105 F Characteristic Measure Temperature, storage -30 C to 90 C -40 F to 195 F Quantity 2 For m C or 3 For m A (factor y option) Response time Same as input Relay energized when less than, greater than, inside or outside DISPlA y SPECIFICATIONS signal is set points Characteristic Measure Contact ratings 1 A 30 Vdc, 0.5 A 50 Vac Display type Vacuum fluorescent Not RoHS compliant Numeric display for mat +999999 to -999999 (0, 1, 2, 3, 4, 5 decimal places) Digit size, nor mal mode 5 mm x 2,5 mm 0.2 in x 0.1 in (with (H x W) engineering units) OPTION CODES Digit size, large mode 10 mm x 5 mm 0.4 in x 0.2 in (no engi- Many range/option combinations are available in (H x W) neering units) our quick-ship and fast-track manufacture pro- grams. Please see