Model 2110-2116
Flanged Reaction Torque Sensor
DESCRIPTION
Model 2110-2116 flanged reaction torque sensor is designed for strain gages on a special machined portion of the transducer to
installation between test pieces such as motors, switches, axles, achieve a maximum non-linearity of 0.1% over a wide dynamic
or shafts and their mounting plate. These models operate and range. Typical applications include tire braking, motor dyna-
are calibrated in both directions. Nickel-plated alloy steel con- mometers, friction-skid testing, and twist measurement. 2000
struction enhances durability in harsh, industrial environments. in-lb to 2400000 in-lb capacities.
These models have no moving parts and utilize four bonded
FEATURES
2000 in-lb to 2400000 in-lb capacities
0.1 % non-linearity and hysteresis
High torsional stiffness
Higher resistance to bending moments
Low-end sensitivity due to absence of moving par ts
Safety considerations: It would be unsafe to operate Honeywell torque sensors and
load cells beyond static overload or ultimate extraneous load limits as defined in
the glossary of terms or, when applicable, higher than maximum speed. When in
doubt, consult factor y. Honeywell is not responsible for any proper ty damage or
personal injury which may result because of the misapplication of the transducer.Model 2110-2116
TYPICAL SYSTEM DIAGRAM
PERFORMANCE SPECIFICATIONS
In-Line Amplifiers
Customer Supplied
Characteristic Measure
(Used with unamplified units only)
Chart Recorder
Torque range 2000 lb-in to 2400000 lb-in
Alarm Panel
Amplifier Output
Data Acquisition
Universal In-Line Amplifiers
Non-linearity 0.1 % of rated output
Computer
+/-5 VDC MS-3102E-145-5P
UV
+/-10 VDC PLC
UV-10
Hysteresis 0.1 % of rated output
UBP 0 +/-5 VDC
U3W 4-20mA (3 wire)
Repeatability 0.05 % of rated output
U2W 4-20mA (2 wire)
DIN rail Mount In-Line Amplifiers
Output @ rated capacity 2 mV/V (nominal)
Power Supply
DV-05 0 +/- 5 VDC (3 wire)
DA-05 4-20mA (3 wire)
0 +/- 10 VDC (3 wire)
DV10
G D
G
Honeywell
In-Line Amplifier
Output Input
Serial Number
H
H
ENVIRONMENTAL SPECIFICATIONS
For long cable runs or electrically
noisy environments an amplified
Display Units
Characteristic Measure
sensor or locally mounted amplifier
is often preferred
SC500 SC1000 SC2000
N N
Temperature, operating -54 C to 93 C [-65 F to 200 F]
SC2001 SC3004
GM NK HH
MODEL 2110-2116
Temperature, compensated 21 C to 77 C [70 F to 170 F]
C
7541 7558 7561-PSD
Temperature effect, zero 0.002 %/of rated output F
Temperature effect, output 0.002 %/of reading F
2003.1 lb.
L1 L2 L3 L4
VALUE CLEAR CHAN TARE
UP DOWN SETUP ENTER EXIT
Mating Connectors & Cables
ELECTRICAL SPECIFICATIONS
064-LW13621 Mating Connector
7200-76-XX* Mating connector & 6 conductor cable
Characteristic Measure
(unamplified unit with sense leads but not shunt cal)
7200-75-XX** Mating connector & 4 conductor cable
Excitation (maximum) 20 Vdc or Vac RMS
(unamplified unit without sense leads but not shunt cal)
7200-111-XX* Mating connector & 6 conductor cable
J
Insulation resistance > 5000 mOhm @ 50 Vdc F B.C.
(for connection to instrument 7541)
7200-110-XX** Mating connector & 4 conductor cable
Bridge resistance 350 ohm (nominal)
(for connection to instrument 7541)
Number of bridges 1
* XX represents length in feet 100ft maximum
** XX represents length in feet 20ft maximum
Zero balance 1.0 % of rated output
LOAD CARRYING CAPACITY
S
S
P
P
W
W
W - weight
W x S - overhung moment
MODEL 2110 MODEL 2404
S - distance to W
Do not exceed moment (W x S) or shear (W), whichever value is attained first
P = thrust
2 Honeywell Sensing and Control