Model 2110-2116 Flanged Reaction Torque Sensor DESCRIPTION Model 2110-2116 flanged reaction torque sensor is designed for strain gages on a special machined portion of the transducer to installation between test pieces such as motors, switches, axles, achieve a maximum non-linearity of 0.1% over a wide dynamic or shafts and their mounting plate. These models operate and range. Typical applications include tire braking, motor dyna- are calibrated in both directions. Nickel-plated alloy steel con- mometers, friction-skid testing, and twist measurement. 2000 struction enhances durability in harsh, industrial environments. in-lb to 2400000 in-lb capacities. These models have no moving parts and utilize four bonded FEATURES 2000 in-lb to 2400000 in-lb capacities 0.1 % non-linearity and hysteresis High torsional stiffness Higher resistance to bending moments Low-end sensitivity due to absence of moving par ts Safety considerations: It would be unsafe to operate Honeywell torque sensors and load cells beyond static overload or ultimate extraneous load limits as defined in the glossary of terms or, when applicable, higher than maximum speed. When in doubt, consult factor y. Honeywell is not responsible for any proper ty damage or personal injury which may result because of the misapplication of the transducer.Model 2110-2116 TYPICAL SYSTEM DIAGRAM PERFORMANCE SPECIFICATIONS In-Line Amplifiers Customer Supplied Characteristic Measure (Used with unamplified units only) Chart Recorder Torque range 2000 lb-in to 2400000 lb-in Alarm Panel Amplifier Output Data Acquisition Universal In-Line Amplifiers Non-linearity 0.1 % of rated output Computer +/-5 VDC MS-3102E-145-5P UV +/-10 VDC PLC UV-10 Hysteresis 0.1 % of rated output UBP 0 +/-5 VDC U3W 4-20mA (3 wire) Repeatability 0.05 % of rated output U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers Output rated capacity 2 mV/V (nominal) Power Supply DV-05 0 +/- 5 VDC (3 wire) DA-05 4-20mA (3 wire) 0 +/- 10 VDC (3 wire) DV10 G D G Honeywell In-Line Amplifier Output Input Serial Number H H ENVIRONMENTAL SPECIFICATIONS For long cable runs or electrically noisy environments an amplified Display Units Characteristic Measure sensor or locally mounted amplifier is often preferred SC500 SC1000 SC2000 N N Temperature, operating -54 C to 93 C -65 F to 200 F SC2001 SC3004 GM NK HH MODEL 2110-2116 Temperature, compensated 21 C to 77 C 70 F to 170 F C 7541 7558 7561-PSD Temperature effect, zero 0.002 %/of rated output F Temperature effect, output 0.002 %/of reading F 2003.1 lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN SETUP ENTER EXIT Mating Connectors & Cables ELECTRICAL SPECIFICATIONS 064-LW13621 Mating Connector 7200-76-XX* Mating connector & 6 conductor cable Characteristic Measure (unamplified unit with sense leads but not shunt cal) 7200-75-XX** Mating connector & 4 conductor cable Excitation (maximum) 20 Vdc or Vac RMS (unamplified unit without sense leads but not shunt cal) 7200-111-XX* Mating connector & 6 conductor cable J Insulation resistance > 5000 mOhm 50 Vdc F B.C. (for connection to instrument 7541) 7200-110-XX** Mating connector & 4 conductor cable Bridge resistance 350 ohm (nominal) (for connection to instrument 7541) Number of bridges 1 * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum Zero balance 1.0 % of rated output LOAD CARRYING CAPACITY S S P P W W W - weight W x S - overhung moment MODEL 2110 MODEL 2404 S - distance to W Do not exceed moment (W x S) or shear (W), whichever value is attained first P = thrust 2 Honeywell Sensing and Control