Solid State Sensors CS Series Linear Current Sensors FEATURES LINEAR CURRENT SENSORS 1 Linear output MICRO SWITCH CS series linear current 1 AC or DC current sensing sensors incorporate our 91SS12-2 and 1 Through-hole design SS94A1linear output Hall effect transduc- TM 1 Fast response time er (LOHET ). The sensing element is as- 1 Output voltage isolation from input sembled in a printed circuit board mount- 1 Minimum energy dissipation able housing. This housing is available in 1 Maximum current limited only by four configuration as shown in mounting conductor size dimension figures 1, 1a, 2 and 2a. Normal 1 Adjustable performance and built-in mounting is with 0.375 inch long 4-40 temperature compensation assures screw and square nut (not provided) in- reliable operation serted in the housing or a 6-20 self-tap- 1 Accurate, low cost sensing ping screw. The combination of the sen- 1 Operating temperature range 25 to sor, flux collector, and housing compris- 85C es the holder assembly. These sensors 1 Housing: PET polyester are ratiometric. ORDER GUIDE BOTTOM MOUNT WITH 9SS SENSOR, SOURCE OUTPUT Sensitivity Sensed mV&N* Mtg. Supply Supply Current Offset Offset Response At 12 VDC Catalog Dim. Volt. Current (Amps Volt. Shift Time Listing Fig. (Volts DC) (mA Max.) Peak) (Volts10%) Nominal TOL (%/C) ( Sec.) CSLA1CD 1 8 to 16 19 57 Vcc/2 49.6 5.8 .05 3 CSLA1CE 1 8 to 16 19 75 Vcc/2 39.4 4.4 .05 3 CSLA1DE 2 8 to 16 19 75 Vcc/2 39.1 4.8 .05 3 CSLA1CF 1 8 to 16 19 100 Vcc/2 29.7 2.7 .05 3 CSLA1DG 2 8 to 16 19 120 Vcc/2 24.6 2.1 .05 3 CSLA1CH 1 8 to 16 19 150 Vcc/2 19.6 1.8 .05 3 CSLA1DJ 2 8 to 16 19 225 Vcc/2 13.2 1.2 .05 3 CSLA1EJ 1a 8 to 16 19 225 Vcc/2 13.2 1.5 .05 3 CSLA1DK 2 8 to 16 19 325 Vcc/2 9.1 1.7 .05 3 CSLA1EK 1a 8 to 16 19 325 Vcc/2 9.4 1.3 .05 3 CSLA1EL 1a 8 to 16 19 625 Vcc/2 5.6 1.3 .05 3 BOTTOM MOUNT WITH SS9 SENSOR, SINK/SOURCE OUTPUT Sensitivity Sensed mV&N* Mtg. Supply Supply Current Offset Offset Response At 8 VDC Catalog Dim. Volt. Current (Amps Volt. Shift Time Listing Fig. (Volts DC) (mA Max.) Peak) (Volts2%) Nominal TOL (%/C) ( Sec.) CSLA2CD 1 6 to 12 20 72 Vcc/2 32.7 3.0 .02 3 CSLA2CE 1 6 to 12 20 92 Vcc/2 26.1 2.1 .02 3 CSLA2DE 2 6 to 12 20 92 Vcc/2 25.6 2.2 .02 3 CSLA2CF 1 6 to 12 20 125 Vcc/2 19.6 1.3 .02 3 CSLA2DG 2 6 to 12 20 150 Vcc/2 16.2 1.1 .02 3 CSLA2DJ 2 6 to 12 20 225 Vcc/2 8.7 0.6 .020 3 CSLA2DH 2 6 to 12 20 235 Vcc/2 9.8 1.1 .0125 3 CSLA2EJ 1a 6 to 12 20 310 Vcc/2 7.6 0.7 .0125 3 CSLA2DK 2 6 to 12 20 400 Vcc/2 5.8 0.5 .0125 3 CSLA2EL 1a 6 to 12 20 550 Vcc/2 4.3 0.4 .0125 3 CSLA2EM 1a 6 to 12 20 765 Vcc/2 3.1 0.3 .007 3 CSLA2EN 1a 6 to 12 20 950 Vcc/2 2.3 0.2 .007 3 NOTE: When monitoring purely AC current with zero DC component, a capacitor can be inserted in series with the output of the current sensor. The capacitor will block out the effect of the temperature variation of the offset voltage which increases the accuracy of the device. *N = number of turns PDFINFO p a g e - 0 5 8 58 Honeywell Sensing and Control1 1-800-537-6945 USA1 F1-815-235-6847 International 1 1-800-737-3360 CanadaCurrent Solid State Sensors CS Series Linear Current Sensors SIDE MOUNT WITH 9SS SENSOR, SOURCE OUTPUT Sensitivity Sensed mV&N* Mtg. Supply Supply Current Offset Offset Response At 12 VDC Catalog Dim. Volt. Current (Amps Volt. Shift Time Listing Fig. (Volts DC) (mA Max.) Peak) (Volts10%) Nominal TOL (%/C) ( Sec.) CSLA1GD 2a 8 to 16 19 57 Vcc/2 49.6 5.8 .05 3 CSLA1GE 2a 8 to 16 19 75 Vcc/2 39.4 4.4 .05 3 CSLA1GF 2a 8 to 16 19 100 Vcc/2 29.7 2.7 .05 3 SIDE MOUNT WITH SS9 SENSOR, SINK/SOURCE OUTPUT Sensitivity Sensed mV&N* Mtg. Supply Supply Current Offset Offset Response At 8 VDC Catalog Dim. Volt. Current (Amps Volt. Shift Time Listing Fig. (Volts DC) (mA Max.) Peak) (Volts2%) Nominal TOL (%/C) ( Sec.) CSLA2GD 2a 6 to 12 20 72 Vcc/2 32.7 3.0 .02 8 CSLA2GE 2a 6 to 12 20 92 Vcc/2 26.1 2.1 .02 8 CSLA2GF 2a 6 to 12 20 125 Vcc/2 19.6 1.3 .02 8 CSLA2GG 2a 6 to 12 20 150 Vcc/2 12.7 0.6 .02 8 NOTE: When monitoring purely AC current with zero DC component, a capacitor can be inserted in series with the output of the current sensor. The capacitor will block out the effect of the temperature variation of the offset voltage which increases the accuracy of the device. *N = number of turns. MOUNTING DIMENSIONS (for reference only) Figure 1 Figure 2 PDFINFO p a g e - 0 5 9 Figure 1a Figure 2a * Application consideration: The out- put is clamped at the high end. Clamp- ing voltage may be as low as 9VDC. The output will not exceed the clamp- ing voltage regardless of field strength or supply voltage. Honeywell Sensing and Control1 1-800-537-6945 USA1 F1-815-235-6847 International 1 1-800-737-3360 Canada 59