MICRO SWITCH Global Miniature Limit Switches 107147 GLC GLD GLE Series Issue 18 Datasheet FEATURES Designed to EN50047 standard Metal housing or double-insulated plastic housing for indoor and outdoor applications Wide range of actuator heads and levers Heads can be positioned at 90 increments for design flexibility. Side rotary actuator heads can be factory set for CW, CCW, or CW and CCW actuation 1 Certified for global applications: CE, UL, CSA, CCC Conforms to CE, EN50047, IEC/EN 60947-5-1 CSA C22.2 14 1 UL 508 CCC GB14048.5, EN45545-2 (GLC/GLE) Sealed to IP66 and NEMA/UL 1, 4, 12, and 13 -40 C -40 F standard construction for side rotary and plunger actuated switches suitable for many severe outdoor environments DESCRIPTION Dual bearing design on side rotary actuators reduces side Honeywell MICRO SWITCH GLS miniature limit switch family loading and enhances mechanical life offers a wide range of products for global solutions. These Variety of NC and NO double-break snap-action or slow- durable and reliable limit switches are suitable for many industrial action contact options applications, agriculture equipment, transportation equipment, Silver contacts for power switching or gold-plated contacts for and other applications requiring an environmentally sealed (IP low energy loads and NEMA) switch. Normally closed contacts are positive opening , and The compact housings are often ideal for equipment where conform to EN/IEC 60947-5-1-3 to provide forced opening of space is at a premium. The extensive product range is available the normally closed contact. Each contact throw is electrically in three different housing types metal housing, plastic housing isolated to accept different voltages (Form Zb contacts). or a three conduit metal housing which are mounting compatible Double pole double throw (2NC/2NO) contact option require to EN50047. A wide range of actuators, contact blocks, and same polarity for each pole. (Form Za for each pole) conduit/connectivity options enhance the product offering. Contact blocks are available as snap action or slow action Mechanical life up to 10 million operations In todays demanding age of logic-level controls, electromechanical switches are frequently used to interface POTENTIAL APPLICATIONS with PLCs and other logic level devices. GLS limit switches offer Passenger elevators an option for gold-plated contacts for the standard switch. This Commerical appliances option promotes the switch reliability for logic-level applications. Escalators/moving stairs Scissor/platform lifts VALUE TO CUSTOMERS Material handling Meets EN50047 mounting standards and EN/IEC electrical Machine tool equipment standards for world-wide use Off-road equipment Large existing install base and channel allows for quick delivery worldwide PORTFOLIO Wide range of actuators and circuitry options in same The GLC Series, GLD Series, and GLE Series are a segment footprint 1 of Honeywells global limit switch offering. The global limit Certified for global use with CCC , CSA, CE, and UL switch products also include the GLA Series, the GLL Series, acceptance the NGC Series, and SZL-VL series. In addition to the global limit switch series, Honeywell provides a comprehensive line DIFFERENTIATION of medium duty industrial limit switches (CE Series, E6/V6 Modular design of limit switch (heads/actuators, bodies, and Series, LS Series) and heavy-duty HDLS Series (Heavy Duty contact blocks) allows for rapid customization and delivery Removable contact block for wiring ease Limit Switch). 1 Galvanically isolated contacts for controlling two separate CCC certification is not available on the GL Series Switches sold within Europe, Middle East, and Africa. Option for CCC certification in these circuits regions is available upon request. Sensing and Internet of ThingsMICRO SWITCH Global Miniature Limit Switches, GLC GLD GLE Series Table 1. Specifications Characteristic Parameter GLC Series and GLE Series: Electrostatic epoxy coated zinc Housing material GLD Series: High-strength glass re-enforced thermoplastic Actuators Side rotary, top pin plunger, top roller plunger, top roller lever, top wobble actuator 0.5-14 NPT, PG 13,5, 20 mm, PF 1/2, Deutsch style 4-pin connector Termination other cable/connector options available, contact the Honeywell Representative GLC metal housing and GLD plastic housing: 1NC/1NO, 2NC, 2NO Contact options* GLE metal housing, 1NC/1NO, 2NC, 2NO, 2NC/2NO Contact type snap-action, slow-action break-before-make (BBM), slow-action make-before-break (MBB), slow action Contact material silver (standard), gold plated (low-energy applications) Thermal current (Ith) 10 A Rated insulation voltage 300 V Rated impulse voltage 2.5 kV Sealing NEMA 1, 4, 12, 13 IP66 Operating temperature -40 C to 85 C -40 F to 185 F Mechanical life Up to 10 million cycles Pollution code 3 Max. actuation frequency 250 operations/minute 100 operations/minute (wobbles) Shock 50 g per IEC 60068-2-27 Vibration 10 g per IEC 60068-2-6 1 Approvals CE, UL, CSA and CCC Conforming to standards CE, EN50047, IEC/EN 60947-5-1 CSA C22.2 14 UL 508 CCC GB14048.5 EN45545-2 (GLC/GLE) 1 *All normally closed contacts are positive opening . The two contact elements are Zb (electrically separated) except the 2NC/2NO contacts requires same polarity each pole (Za). 1 CCC certification is not available on the GL Series Switches sold within Europe, Middle East, and Africa. Option for CCC certification in these regions is available upon request. Table 2. Electrical Rating IEC 60947-5-1 (EN60947-5-1) AC 15, A300 DC 13, Q300 Silver Contacts Gold Contacts ac dc A300 AC15 VA Q300 DC13 VA 1 V 10 mA min. Ue Ie Ue Ie 50 V 100 mA max. Volts Amps Make Break Volts Amps Make Break 120 6 7200 720 125 0.55 69 69 240 3 7200 720 250 0.27 69 69 2 sensing.honeywell.com