Honeywell Pressure Switches 50094081
HP, HE, MH, ME, LP, LE, 5000, and 1000 Series Issue 5
Datasheet
DESCRIPTION FEATURES
The Honeywell Pressure Switch portfolio consists of: Pressure switching set point range: 3.5 psi to 4500 psi
Proof pressure: from 500 psi up to 10,000 psi
High Pressure (HE/HP Series)
Burst pressure: from 1250 psi up to 20,000 psi
Medium Pressure (ME/MH Series)
Life cycle rating up to 2 million
Low Pressure (LE/LP Series)
4
IP67 sealing rating
5000 Series, 1000 Series
Operating temperature: -40 C to 120 C [-40 F to 248 F]
These pressure switches are durable, reliable
5
Hysteresis option
electromechanical gauge pressure on/off switches that are
More than 15 pressure port options and over 30 electrical
available with either single pole single throw (SPST) normally
terminations
open or normally closed circuitry, or single pole double throw
3
Plated steel, brass or stainless steel options
(SPDT) circuitry. Their high proof pressure and burst pressure
Switching point accuracy up to 2 %
ratings can allow for use in many rugged applications that
require the making or breaking of an electrical connection in
POTENTIAL APPLICATIONS
response to a pressure change of the system media.
DIFFERENTIATION
Through optional smart diagnostic technology,
Honeywell pressure switches are able to detect failures
Agricultural machinery CNC machines
such as open circuits, cut wires, worn insulation, and
6
Heavy duty construction Compressors/boilers
more
machinery and trucks Fracking equipment
Optional smart diagnostic technology allows up to four
Lawn & garden machinery Food & beverage equipment
segregated signal amplitudes to perform diagnostics and
Marine vessels Generators
6
status
Material handling HVAC/R equipment
2
Pressure port snubber suppresses pressure spikes
machinery Mud pumps
IP67 sealing provides enhanced durability in harsh
Railway Pneumatic equipment
1
environmental and washing applications
Presses/punches
Pressure washers
VALUE TO CUSTOMERS Trash compactors
Water pumps & jet cutting
Designed to provide resistance to corrosion and enhances
machines
equipment life with available two million life cycle rating and
1
PORTFOLIO
IP67 rating
Honeywell also offers the PBN1 Series and PBN3 Series
Can expedite design and product cycle due to ability to
Pressure Sensor.
receive samples in two weeks and production units in four
1
HP, HE, MH, ME, LP, LE Series
weeks
2
HP, HE Series
Can reduce tooling, service, and manufacturing labor costs
3
ME, MH, LP, LE Series
due to standard connections, extended product life, and 4
HP, HE, LP, LE, ME Series
5
HP, HE, LP Series
expedited design and production cycle
6
HP, HE, ME, LP, LE Series
Safety and Productivity SolutionsHoneywell Pressure Switches, HP, HE, MH, ME, LP, LE, 5000, 1000 Series
Table 1. Specifications
Character-
HP Series HE Series ME Series MH Series LP Series LE Series 5000 Series 1000 Series
istic
Product
length (various
see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9 see page 10
terminations)
Product length 58,42 mm 65,6 mm
see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9
(blade) [2.3 in] [2.583 in]
Product length 60,96 mm
see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9
(#8-32 screws) [2.4 in]
Product length 73,66 mm
see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9
(Metripack) [2.9 in]
0.50 in (steel) M10 x 1.25 banjo
Hex size 27 mm 27 mm 27 mm 27 mm 27 mm 27 mm
0.437 in (brass) fitting
Ease of 18 mm open
box spanner box spanner box spanner box spanner box spanner box spanner 1/2 in open spanner
installation spanner
Snap-action
yes yes no no yes no no no
switch
1
Set point 10 psi to 60 psi
100 psi to 4500 psi 150 psi to 4500 psi 25 psi to 350 psi 40 psi to 500 psi 3.5 psi to 150 psi 3.5 psi to 150 psi 75 psi to 150 psi
range [0,69 bar to 2,7 bar]
Set point 6 (Base Style A)
6 4 4 4 4 8
ranges 7 (Base Style B)
0.5 psi to 1 psi
(0.3 psi);
40 psi to 70 psi 1.1 psi to 3 psi
25 psi to 50 psi (7 psi); (0.5 psi);
100 psi to 150 psi 150 psi to 1000 psi
(3 psi); >70 psi to 130 psi 3.1 psi to 7 psi
(10 %); (14%);
>50 psi to 100 psi (10 psi); (1 psi);
150 psi to 500 psi 1000 psi to
Set point (7 psi); >130 psi to 200 psi 3.5 psi to 10 psi (1 psi); 8 psi to 13 psi
(6 %); 2000 psi 20 psi 10 psi;
accuracy >100 psi to 150 psi (15 psi); >10 psi to 50 psi (3 psi); (2 psi);
501 psi to 4000 psi (12 %); 58 psi 20 psi
@ 25 C (10 psi); >200 psi to 280 psi >50 psi to 100 psi (7 psi); 14 psi to 24 psi
(3.5 %); 2000 psi to
(before test) >150 psi to 250 psi (20 psi); >100 psi to 150 psi (10 psi) (3 psi);
4000 psi to 4500 4000 psi
(13 psi); >280 psi to 350 psi 25 psi to 50 psi
psi (11 %);
>250 psi to 350 psi (30 psi); (5 psi);
(2 %) >4000 psi (10 %)
(16 psi) >350 psi to 500 psi 51 psi to 90 psi
(40 psi) (7 psi);
91 psi to 150 psi
(10 psi)
0.5 psi to 3 psi
40 psi to 70 psi (1.5 psi);
25 psi to 50 psi (6 psi); 4 psi to 7 psi
(20 psi); >70 psi to 130 psi 3.5 psi to 10 psi (2.5 psi);
>50 psi to 100 psi (10 psi); (2.8 psi); 8 psi to 13 psi
(30 psi); >130 psi to 200 psi >10 psi to 50 psi (3.5 psi);
Average dead- >100 psi to 150 psi (15 psi); (14 psi); 14 psi to 24 psi
n/a n/a n/a n/a
band max. (40 psi); >200 psi to 280 psi >50 psi to 100 psi (8 psi);
>150 psi to 250 psi (20 psi); (38 psi); 25 psi to 50 psi
(50 psi); >280 psi to 350 psi >100 psi to 150 psi (15 psi);
>250 psi to 350 psi (30 psi); (40 psi) 51 psi to 90 psi
(60 psi) >350 psi to 500 psi (23 psi);
(40 psi) 91 psi to 150 psi
(40 psi)
Operating 1400 psi
5,000 psi max. 5,000 psi max. 500 psi max. 600 psi max. 250 psi max. 250 psi max. 150 psi, 250 psi
2
pressure [96,5 bar] max.
10,000 psi (Base
Style A) 2973 psi
3
Proof pressure 10,000 psi 4,000 psi 6,000 psi 500 psi 500 psi 500 psi
6,500 psi (Base [205 bar]
Style B)
5 % to 55 % 3 % to 65 % 5 % to 55 %
Hysteresis (based on set point (based on set point n/a n/a (based on set point n/a n/a n/a
range) range) range)
20,000 psi (Base
3500 psi
4
Burst pressure Style A); 9,000 psi 20,000 psi 8,000 psi 9,000 psi 1250 psi 1250 psi 4000 psi
[241 bar]
(Base Style B)
15 A, 6 Vdc;
Current rating 5 A at 250 Vac 3 A at 250 Vac 7.5 mA to 3 A, 7.5 mA to 5 A, 7.5 mA to 3 A, 12 Vdc with two-
100 mA to 3 A max. 8 A, 12 Vdc;
(resistive) 5 A at 24 Vdc 3 A at 24 Vdc 24 Vdc and 250 Vac 24 Vdc and 250 Vac 24 Vdc and 250 Vac 1157 bulbs (4.4 A)
4 A, 24 Vdc
Current rating 5 A at 115 Vac (SX 1 A, 120 Vac
n/a n/a n/a 1 A at 28 Vdc n/a n/a
(inductive) rating); 3 A at 28 Vdc 0.5 A, 240 Vac
8
Port Style C: Switches less than 975 psi will use Base Style B; switches greater than 975 psi will use Base Style A.
Port Styles F and G: Switches less than 350 psi will use Base Style B; switches greater than 350 psi will use Base Style A.
Port Styles A, B, E, M, P, T, and Y will use Base Style B.
Switches less than 150 psi will only use Base Style B.
2 sensing.honeywell.com