50094081 Issue 6 PRESSURE SWITCHES HP, HE, MH, ME, LP, LE, 5000, and 1000 Series DESCRIPTION VALUE TO CUSTOMERS POTENTIAL APPLICATIONS The Honeywell Pressure Switch portfolio Designed to provide resistance to consists of: corrosion and enhances equipment life with available two million life cycle High Pressure (HE/HP Series) 1 rating and IP67 rating Medium Pressure (ME/MH Series) Can expedite design and product cycle Low Pressure (LE/LP Series) Agricultural CNC machines due to ability to receive samples in two 5000 Series, 1000 Series machinery Compressors/ weeks and production units in four Heavy duty boilers These pressure switches are durable, weeks construction Fracking reliable electromechanical gauge Can reduce tooling, service, and machinery and equipment pressure on/off switches that are manufacturing labor costs due to trucks Food & beverage available with either single pole single standard connections, extended Lawn & garden equipment throw (SPST) normally open or normally product life, and expedited design and machinery Generators closed circuitry, or single pole double production cycle Marine vessels HVAC/R throw (SPDT) circuitry. Their high proof Material equipment pressure and burst pressure ratings handling Mud pumps FEATURES can allow for use in many rugged machinery Pneumatic Pressure switching set point range: applications that require the making or Railway equipment 3.5 psi to 4500 psi breaking of an electrical connection in Presses/ Proof pressure: from 500 psi up to punches response to a pressure change of the 10,000 psi Pressure system media. Burst pressure: from 1250 psi up to washers 20,000 psi Trash DIFFERENTIATION Life cycle rating up to 2 million compactors 4 Through optional smart diagnostic IP67 sealing rating Water pumps technology, Honeywell pressure Operating temperature: -40C to 120C & jet cutting switches are able to detect failures machines -40F to 248F 5 such as open circuits, cut wires, PORTFOLIO Hysteresis option 6 worn insulation, and more Honeywell also offers the PBN1 Series More than 15 pressure port options Optional smart diagnostic technology and PBN3 Series Pressure Sensor. and over 30 electrical terminations allows up to four segregated signal 1 Plated steel, brass or stainless steel HP, HE, MH, ME, LP, LE Series 2 3 HP, HE Series amplitudes to perform diagnostics and options 3 ME, LP, LE Series 6 status Switching point accuracy up to 2 % 4 HP, HE, LP, LE, ME Series Pressure port snubber suppresses 5 HP, HE, LP Series 2 6 HP, HE, ME, LP, LE Series pressure spikes IP67 sealing provides enhanced durability in harsh environmental and 1 washing applications PRESSURE SWITCHES, HP, HE, MH, ME, LP, LE, 5000, 1000 SERIES TABLE 1. SPECIFICATIONS Character- HP Series HE Series ME Series MH Series LP Series LE Series 5000 Series 1000 Series istic Product length (various see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9 see page 10 terminations) Product length 58,42 mm 65,6 mm see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9 (blade) 2.3 in 2.583 in Product length 60,96 mm see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9 ( 8-32 screws) 2.4 in Product length 73,66 mm see pages 5 and 6 see page 5 see page 8 see page 7 see page 9 see page 9 (Metripack) 2.9 in 0.50 in (steel) M10 x 1.25 banjo Hex size 27 mm 27 mm 27 mm 27 mm 27 mm 27 mm 0.437 in (brass) fitting Ease of 18 mm open box spanner box spanner box spanner box spanner box spanner box spanner 1/2 in open spanner installation spanner Snap-action yes yes no no yes no no no switch 1 Set point 10 psi to 60 psi 100 psi to 4500 psi 150 psi to 4500 psi 25 psi to 350 psi 40 psi to 500 psi 3.5 psi to 150 psi 3.5 psi to 150 psi 75 psi to 150 psi range 0,69 bar to 2,7 bar Set point 6 (Base Style A) 6 4 4 4 4 8 ranges 7 (Base Style B) 0.5 psi to 1 psi (0.3 psi) 40 psi to 70 psi 1.1 psi to 3 psi 25 psi to 50 psi (7 psi) (0.5 psi) 100 psi to 150 psi 150 psi to 1000 psi (3 psi) >70 psi to 130 psi 3.1 psi to 7 psi (10 %) (14%) >50 psi to 100 psi (10 psi) (1 psi) 150 psi to 500 psi 1000 psi to Set point (7 psi) >130 psi to 200 psi 3.5 psi to 10 psi (1 psi) 8 psi to 13 psi (6 %) 2000 psi 20 psi 10 psi accuracy >100 psi to 150 psi (15 psi) >10 psi to 50 psi (3 psi) (2 psi) 501 psi to 4000 psi (12 %) 58 psi 20 psi 25C (10 psi) >200 psi to 280 psi >50 psi to 100 psi (7 psi) 14 psi to 24 psi (3.5 %) 2000 psi to (before test) >150 psi to 250 psi (20 psi) >100 psi to 150 psi (10 psi) (3 psi) 4000 psi to 4500 4000 psi (13 psi) >280 psi to 350 psi 25 psi to 50 psi psi (11 %) >250 psi to 350 psi (30 psi) (5 psi) (2 %) >4000 psi (10 %) (16 psi) >350 psi to 500 psi 51 psi to 90 psi (40 psi) (7 psi) 91 psi to 150 psi (10 psi) 0.5 psi to 3 psi 40 psi to 70 psi (1.5 psi) 25 psi to 50 psi (6 psi) 4 psi to 7 psi (20 psi) >70 psi to 130 psi 3.5 psi to 10 psi (2.5 psi) >50 psi to 100 psi (10 psi) (2.8 psi) 8 psi to 13 psi (30 psi) >130 psi to 200 psi >10 psi to 50 psi (3.5 psi) Average dead- >100 psi to 150 psi (15 psi) (14 psi) 14 psi to 24 psi n/a n/a n/a n/a band max. (40 psi) >200 psi to 280 psi >50 psi to 100 psi (8 psi) >150 psi to 250 psi (20 psi) (38 psi) 25 psi to 50 psi (50 psi) >280 psi to 350 psi >100 psi to 150 psi (15 psi) >250 psi to 350 psi (30 psi) (40 psi) 51 psi to 90 psi (60 psi) >350 psi to 500 psi (23 psi) (40 psi) 91 psi to 150 psi (40 psi) Operating 1400 psi 5,000 psi max. 5,000 psi max. 500 psi max. 600 psi max. 250 psi max. 250 psi max. 150 psi, 250 psi 2 pressure 96,5 bar max. 10,000 psi (Base Style A) 2973 psi 3 Proof pressure 10,000 psi 4,000 psi 6,000 psi 500 psi 500 psi 500 psi 6,500 psi (Base 205 bar Style B) 5 % to 55 % 3 % to 65 % 5 % to 55 % Hysteresis (based on set point (based on set point n/a n/a (based on set point n/a n/a n/a range) range) range) 20,000 psi (Base 3500 psi 4 Burst pressure Style A) 9,000 psi 20,000 psi 8,000 psi 9,000 psi 1250 psi 1250 psi 4000 psi 241 bar (Base Style B) 15 A, 6 Vdc Current rating 5 A at 250 Vac 3 A at 250 Vac 7.5 mA to 3 A, 7.5 mA to 5 A, 7.5 mA to 3 A, 12 Vdc with two- 100 mA to 3 A max. 8 A, 12 Vdc (resistive) 5 A at 24 Vdc 3 A at 24 Vdc 24 Vdc and 250 Vac 24 Vdc and 250 Vac 24 Vdc and 250 Vac 1157 bulbs (4.4 A) 4 A, 24 Vdc Current rating 5 A at 115 Vac (SX 1 A, 120 Vac n/a n/a n/a 1 A at 28 Vdc n/a n/a (inductive) rating) 3 A at 28 Vdc 0.5 A, 240 Vac 8 Port Style C: Switches less than 975 psi will use Base Style B switches greater than 975 psi will use Base Style A. Port Styles F and G: Switches less than 350 psi will use Base Style B switches greater than 350 psi will use Base Style A. Port Styles A, B, E, M, P, T, and Y will use Base Style B. Switches less than 150 psi will only use Base Style B. 2 sensing.honeywell.com