Limit/Enclosed Limit and Enclosed Switches HDLS Series Rotary Actuated Switches Order guides below and on page A35 pro- ASSEMBLED CONDITIONS vide specification and pricing information Catalog listings in order guide below are for side and top rotary switches. factory assembled with: Plug-in body style catalog listings consist of 1 Shaft of side rotary heads facing front of the complete plug-in base receptacle. switch (label side). Levers are ordered separately. See pages 1 Head adjusted for both clockwise and A37-A39 for lever selection. counterclockwise operation. 1 Light on indicator versions wired to N.O. For rapid response off the shelf service, circuit. all bold face listings are normally stocked Refer to facing page to specify modifica- items. tions to these assembled conditions. PRELEADED OR CONNECTORIZED For low temperature, high VERSIONS temperature or preleading see page Refer to page A42. Side Rotary Top Rotary A42. ORDER GUIDE (Momentary action. UL listed, CSA certified, CE approved. Levers not included. Order separately pages A37-A39.) Catalog Listings Side Rotary Top Rotary Low Electrical Body** Low 5 Low Differential High Circuitry Rating Style Standard Differential Pretravel Torque Low Torque Overtravel Silver contacts A Plug-in LSA1A LSP1A LSU1A LSR1A LSH1A LSB1A 1 2N Conduit Gold cross point contacts C Plug-in LSA1J LSU1J LSB1J 1 2N Conduit Gold plated contacts C LSA1E LSP1E LSR1E LSH1E Silver contacts A* 120 V Ind. lite LSA5A LSP5A LSU5A LSR5A LSH5A LSB5A Plug-In* 1 2N Conduit A* 240 V Ind. lite LSA8A LSP8A LSU8A LSR8A LSH8A LSB8A Plug-In 1 2N Conduit A* 24 V LED lite LSA9A LSP9A LSU9A LSR9A LSH9A LSB9A 1.5mA max. Auto polarity Plug-in 1 2N Conduit A Non plug-in LSA3K LSP3K LSU3K LSR3K LSH3K LSB3K 1 SPDT Double Break 2N Conduit Silver contacts B Plug-in LSA2B LSP2B LSU2B LSR2B LSH2B LSB2B 3 4N Conduit B Plug-in LSA6B LSP6B LSU6B LSR6B LSH6B LSB6B 1 2N Conduit B 120 V Ind. lite LSA2R LSP2R LSU2R LSR2R LSH2R LSB2R Plug-in 3 4N Conduit B Non plug-in LSA4L LSP4L LSU4L LSR4L LSH4L LSB4L 3 4N Conduit DPDT Double Break B Non plug-in LSA7L LSP7L LSU7L LSR7L LSH7L LSB7L 1 2N Conduit D Non plug-in LSA3N LSR3N LSB3N 1 SPNC Direct Acting 2N Conduit *Use at voltage indicated for light. Wired to N.O. circuit. Upper temperature limit for lighted units is 200F (93C). **Plug-in listings include base receptacle. OPERATING CHARACTERISTICS Pretravel (degrees max.) 15 9 5 15 9 25 SPDT 5 3 3 5 3 10 Differential Travel (degrees max.) DPDT 7 4 4 7 4 12 Overtravel (degrees min.) 60 66 70 60 66 110 Operating Torque 0,45 Nm 0,45 Nm 0,45 Nm 0,19 Nm 0,19 Nm 0,28 Nm (max.) NMJNewton meters 4 in. lbs. 4 in. lbs. 4 in. lbs. 1.7 in. lbs. 1.7 in. lbs. 2.5 in. lbs. Operating Temperature Range*** 10F to 250F30F to 250F 12 to 121C1 to 121C ***Completely fluorocarbon-sealed switches are preferred for use in temperatures above 200F (93C). Refer to page A42. Honeywell1 Sensing and Control 1 1-800-537-6945 USA1 F1-815-235-6847 International 1 1-800-737-3360 Canada A33Limit and Enclosed Switches HDLS Series Rotary Actuated Switches ACTUATION DIRECTION LEVERS (Drawings apply to listings on facing page only). Levers for rotary actuated switches are nor- mally ordered as separate catalog listings. They also may be ordered by including a suffix to the switch catalog listing and add- ing the lever price. See pages A34-A39. SWITCHES FOR SPECIAL APPLICATIONS HDLS limit switches for special application needs are described on pages A42 and A43. They include: manifold mount, low temper- ature, complete fluorocarbon-sealed, grav- CW & CCW CW CCW ity return, extra low torque and 20 Amp (Normal) Mod. 1 Mod. 2 switches. Adapter plates for interchanging HDLS with LS/200LS limit switches are described on HEAD ORIENTATION page A49. Mod. 5 Mod. 3 ELECTRICAL RATINGS 10 amps continuous carry (except for elec- trical rating C). Circuits on any one pole Front must be the same polarity. Mod. 4 (Normal) AC Volts Pilot duty: 600 VAC, 720VA Electical Amps at 0.35 Power Factor Rating Circuitry VAC Make Break ASSEMBLY MODIFICATIONS A* Single-Pole 120 60 6 Double-Throw 240 30 3 How to order 480 15 1.5 Momentary action rotary switches can be 600 12 1.2 furnished in other than the normal assem- bled conditions described on the facing B Double-Pole 120 30 3 page. To specify modifications, add the Double-Throw 240 15 1.5 number(s) shown below to the catalog list- 480 7.5 0.75 ings. Prices are the same as their counter- 600 6 0.60 parts shown in the order guide. D Single-Pole 120 60 6 Modification number suffixes are: Single-Throw 240 30 3 1 Clockwise operation only Normally Closed 480 15 1.5 2 Counterclockwise operation only 600 12 1.2 3 Shaft to right of switch front C** Single-Pole 250 VAC or 60 VDC, .050 amp max. 4 Shaft to left of switch front Double-Throw 5 Shaft to back of switch 7 Indicator light wired to N.C. circuit Examples: Catalog Listing LSA1A23 is an LSA1A switch adjusted for counterclockwise operation DC Volts only. The operating shaft is to the right side Pilot duty: 240 VDC, 30 watts of the switch when viewing it from the front Electrical Make and Break Amps (label side). No lever. Rating Circuitry VDC Inductive Resistive Catalog Listing LSA8A7 is an LSA8A switch A* Single-Pole 120 0.25 0.8 with the 240 volt indicator light wired to the Double-Throw 240 0.15 0.4 N.C. circuit. No lever. B Double-Pole 120 0.25 0.8 Switches with assembly modifications are Double-Throw 240 0.15 0.4 not normally stocked and may extend deliv- D Single-Pole 30 4.3 4.3 ery leadtimes. Single-Throw 120 1.1 1.1 Normally Closed C** Single-Pole 250 VAC or 60 VDC, .050 amp max. Double-Throw *For switches with indicator light, use only at voltage stated for indicator light. **These switches have either gold plated or gold cross point contacts. Cross point contacts improve high reliability of contact make when particle contamination is a problem or low energy loads must be carried. A34 Honeywell1 Sensing and Control 1 1-800-537-6945 USA1 F1-815-235-6847 International 1 1-800-737-3360 Canada