32353264 Issue B MIP SERIES Heavy Duty, Media-Isolated Pressure Transducers 1 bar to 12 bar 15 psi to 175 psi DESCRIPTION DIFFERENTIATION The MIP Series offers a heavy duty, Diagnostics: Beneficial in applications media-isolated pressure transducer in a where the sensor functionality and compact, stainless steel construction for the need to know internal or external use with a wide range of media including failure modes is critical. aggressive fluids and water. The MIP Great customer value: Multiple Series provides a cost-competitive configuration possibilities provide solution for wide-ranging potential flexibility of use in the application with applications in tough environments. no up front NRE or tooling charges. Durable: Provides the tough VALUE TO CUSTOMERS environmental capabilities needed, Total Error Band (TEB) 0.75 %FSS including long-term stability, insulation to 1.0 %FSS (Full Scale Span) resistance and dielectric strength, from -40C to 125C: Provides true external freeze-thaw resistance and measurement performance over the EMC performance. compensated temperature range small error promotes system uptime FEATURES and efficiency (see Figure 4). Rugged, stainless steel construction EMC performance: Operates reliably Ratiometric output: 0.5 Vdc to 4.5 Vdc in the presence of electromagnetic Operating temperature: -40C to 125C fields, such as wireless signals, RF Total Error Band 0.75 %FSS to communication, and electrical devices. 1.0 %FSS (-40C to 125C) Hermetically welded design supports Certied to Industry-leading accuracy: 0.15 almost any media without the use of an NSF/ANSI/CAN 61 %FSS BFSL internal seal. The sensors are designed to Long term stability: 0.25 %FSS be used in harsh environments that see Radiated immunity: 100 V/m aggressive media. Drinking water approval: NSF/ANSI/CAN 61 CE, RoHS, REACH compliant TABLE 1. POTENTIAL APPLICATIONS Mis-wiring protection INDUSTRY MEDIA Over voltage protection 40 Vdc Industrial: pumps water, hydraulic fluids compressors compressed air process food, beverage, oil, gas, steam PORTFOLIO Honeywell offers a variety refrigerants (butane, propane, ammonia, CO , R134A, R407C, 2 HVAC/R R410A, R448A/Solstice N40, R32 and R1234ze, R1234yf, of heavy duty pressure glycol + water transducers for potential use in industrial and transportation Transportation gasoline, diesel fuel, engine oil, brake fluid, coolants, CNG applications. To view the entire Medical O , N , CO , N O, air 2 2 2 2 product portfolio, click here.HEAVY DUTY, MEDIA-ISOLATED PRESSURE TRANSDUCERS, MIP SERIES TABLE 2. ELECTRICAL SPECIFICATIONS (AT 25C 77F AND UNDER UNLESS OTHERWISE NOTED.) CHARACTERISTIC PARAMETER Supply voltage 5.0 0.25 Vdc Nominal output transfer function (5 Vdc supply) 0.5 Vdc to 4.5 Vdc Over/reverse voltage 40 Vdc Current consumption 6.5 1 mA Short circuit protection yes TABLE 3. PERFORMANCE SPECIFICATIONS (AT 25C 77F AND UNDER UNLESS OTHERWISE NOTED.) CHARACTERISTIC PARAMETER Operating temperature range -40C to 125C -40F to 257F 1 2 Total Error Band 1.0 %FSS (<10 bar) (-40C to 125C -40F to 257F ) 0.75 %FSS (>10 bar) 3 Accuracy BFSL 0.15 %FSS typ. Long term stability (1000 hr, 25C 77F ) 0.25 %FSS typ. Typical output resolution 0.03 %FSS Response time 1 ms (10% to 90% step change in pressure) 4 Startup time <7 ms typ. EMC rating (CE Conformity): surge immunity (all leads) 1 kV line to ground per IEC 61000-4-5 electrostatic discharge 4 kV contact, 8 kV air per IEC 61000-4-2 radiated immunity 10 V/m (80 MHz to 1000 MHz) per IEC 61000-4-3 fast transient burst 1 kV per IEC 61000-4-4 immunity to conducted disturbances 3 V (150 kHz to 80 MHz) per IEC 61000-4-6 radiated emissions 40 dBV (30 MHz to 230 MHz), 47 dBV (230 MHz to 1000 MHz) per CISPR 11 Radiated immunity 100 V/m (200 MHz to 2 GHz) per ISO 11452-2 Insulation resistance >100 M at 1 kVdc (60 s) Dielectric strength <1 mA at 500 Vac (60 s) Load resistance 2 k (pull up or pull down) Life >10 million full scale pressure cycles 1 Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, pressure non-repeatability, thermal effect on offset, thermal effect on span, and thermal hysteresis (see Figure 4). 2 TEB: 1.5 % FSS above 100C 212F for pressure ratings less than 4 bar 58 psi . 3 Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25C 77F . Includes all errors due to pressure non-linearity, pressure hysteresis, and pressure non-repeatability. 4 Startup time: The time needed to receive valid output after power up. TABLE 4. ENVIRONMENTAL AND MECHANICAL SPECIFICATIONS CHARACTERISTIC PARAMETER Shock 100 G per MIL-STD-202, Method 213, Cond. C (at 25C 77F ) Vibration 20 G sweep, 10 Hz to 2000 Hz (at 25C 77F ) Ingress protection IP67 External freeze/thaw resistance >6 cycles from -30C to 50C -22F to 122F Wetted materials: port stainless steel 304L diaphragm stainless steel 316L external seal for ports nitrile (-30C to 100C -22F to 212F ) (other materials available) Electrical connector material PBT 30%GF (UL V-0) 2 sensing.honeywell.com