Installation Instructions for the ISSUE 1 SS500 Series Temperature 50035318 Compensated Hall Effect Sensors GENERAL INFORMATION Table 1. Absolute Maximum Ratings* Supply voltage -1 Vdc to +30 Vdc CAUTION Voltage externally +30 Vdc max. (OFF only) ELECTROSTATIC DISCHARGE DAMAGE applied to output -0.5 Vdc min. (OFF or ON) This component is sensitive to electrostatic discharge Output ON current see Table 3 (ESD). Take normal ESD precautions in handling this product to prevent ESD-induced damage and/or Operating -50 C to 160 C temperature degradation. -67 F to 320 F Failure to comply with these instructions will result Storage -65 C to 160 C in product damage. temperature -85 F to 320 F Magnetic flux no limit - circuit cannot be damaged by magnetic overdrive CAUTION *Absolute maximum ratings are the extreme limits that the WAVE SOLDER DAMAGE device will withstand without damage to the device. However, DO NOT wave solder this product. Wave soldering may the electrical and mechanical characteristics are not guaranteed as the maximum limits (above recommended negatively affect the sensor performance and reliability. operating conditions) are approached, nor will the device Subjecting the sensor to wave soldering will void necessarily operate at absolute maximum ratings. Honeywells warranty. Failure to comply with these instructions will result SOLDERING INSTRUCTIONS in product damage. Honeywell recommends an infrared reflow process with peak temperatures not to exceed 245 C 473 F for Figure 1. Block Diagram 10 seconds maximum. Vs (+) TRIGGER OUTPUT HALL CIRCUIT (0) N.H. SENSOR AND AMPLIFIER GROUND (-) Table 2. Operating Characteristics (over operating voltage and Table 3. Output Current Absolute temperature, unless otherwise noted) Limits Characteristic Min. Typ. Max. Note Supply Voltage Output Current Supply voltage 3.8 30 Vdc -1 Vdc to 24 Vdc 50 mA max. Current consumption 10 mA 24 Vdc to 25 Vdc 37 mA max. Output voltage (operated) 0.15 0.40 sinking 20 25 Vdc to 26 Vdc 33 mA max. mA max. 26 Vdc to 27 Vdc 28 mA max. 28 Vdc to 29 Vdc 19 mA max. Output current (operated) 20 mA 29 Vdc to 30 Vdc 15 mA max. Output leakage current (released 10 A Output switching time V = 12 V, CC rise, 10% to 90% 0.05 s 1.5 s RL = 1.6 k, fall, 90% to 10% CL = 20 pF 0.15 s 1.5 s Operating temperature range -40 C to 125 C -40 F to 302 F Note: To prevent damage to the leads, SS500 Series is supplied only on tape and reel. Sensing and Control Issue 1 50035318 SS500 Series Table 4. Magnetic Characteristics SS511GT SS513GT SS541GT SS543GT SS549GT SS561GT SS566GT Magnetic Type Bipolar Bipolar Unipolar Unipolar Unipolar Latching Latching max. op. 70 G 140 G 135 G 215 G 435 G 110 G 200 G -40 C min. rel. -70 G -140 G 20 G 80 G 210 G -110 G -200 G min. dif. 15 G 20 G 15 G 25 G 30 G 50 G 200 G max. op 65 G 140 G 117 G 190 G 400 G 90 G 185 G 0 C min. rel. -65 G -140 G 20 G 80 G 230 G -90 G -185 G min. dif. 15 G 20 G 15 G 25 G 30 G 50 G 200 G max. op. 60 G 140 G 115 G 180 G 390 G 85 G 180 G 25 C min. rel. -60 G -140 G 20 G 75 G 235 G -85 G -180 G min. dif. 15 G 20 G 20 G 25 G 30 G 50 G 200 G 85 C max. op. 60 G 140 G 120 G 180 G 400 G 85 G 180 G min. rel. -60 G -140 G 15 G 70 G 215 G -85 G -180 G min. dif. 12 G 20 G 15 G 15 G 30 G 50 G 190 G max. op. 65 G 140 G 123 G 190 G 410 G 100 G 180 G 125 C min. rel. -65 G -140 G 15 G 60 G 200 G -100 G -180 G min. dif. 12 G 20 G 8 G 10 G 30 G 50 G 160 G max. op 70 G 140 G 125 G 200 G 420 G 110 G 185 G 150 C min. rel. -70 G -140 G 10 G 55 G 185 G -110 G -185 G min. dif. 10 G 20 G 5 G 5 G 30 G 50 G 140 G NOTICE Bipolar Hall effect sensors may have an initial output in either the ON or OFF state if powered up with an applied magnetic field in the differential zone (applied magnetic field >Brp and <Bop). Honeywell recommends allowing 10 s for output voltage to stabilize after supply voltage has reached 5 V. Figure 2. Interface Diagrams 2 Honeywell Sensing and Control