Quick Start Guide for the ISSUE 1 Limitless Series WGLA Limit Switch 50053338 used in conjunction with the Limitless WPMM Series WARNING WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency RF EXPOSURE stop devices or in any other application where failure of To satisfy FCC RF exposure requirements for mobile the product could result in personal injury. transmitting devices, a separation distance of 20 cm or Failure to comply with these instructions could result in more should be maintained between the antenna of this death or serious injury. device and persons during device operation To ensure compliance, operation at closer than this distance is not recommended. The antenna used for this transmission WARNING must not be co-located in conjunction with any other antenna or transmitter. Honeywell does not recommend using devices for critical Failure to comply with these instructions could result control applications where there is, or may be, a single point in death or serious injury. of failure or where single points of failure may result in an unsafe condition. It is up to the end-user to weigh the risks WARNING and benefits to determine if the products are appropriate for The WGLA must be installed in accordance with the the application based on security, safety and performance. requirements specified in this document. See Section 3 Additionally, it is up to the end-user to ensure that the control and Section 4 for EIRP requirements. Only the strategy results in a safe operating condition if any crucial specified EIRP power settings, antenna types and segment of the control solution fails. gains and cable lengths (attenuation) as outlined in this Honeywell customers assume full responsibility for learning document are valid for WGLA Series installations. and meeting the required Declaration of Conformity, Regulations, Guidelines, etc. for each country in their CAUTION distribution market. Power to the WGLA should not be applied (ensure Failure to comply with these instructions could result in battery is removed) during installation of antenna as death or serious injury. damage could occur to the WGLA electronics. Sensing and Control Limitless WGLA Series Issue 1 50053338 This WGLA Series quick start installation guide provides basic installation instructions for the WGLA switch used in conjunction with a Limitless Wireless Panel Mount Monitor (WPMM). If necessary, refer to the WGLA or WPMM Installation and Technical Manual for further detailed information regarding installation. 1.1 Antenna Connection WARNING RF EXPOSURE To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of 20 cm 7.87 in or more should be maintained between the antenna of this device and persons during device operation To ensure compliance, operation at closer than this distance is not recommended. The antenna used for this transmission must not be co-located in conjunction with any other antenna or transmitter. Failure to comply with these instructions could result in death or serious injury. CAUTION Power to the WGLA should not be applied (ensure battery is removed) during installation of antenna as damage could occur to the WGLA electronics. The antenna and antenna guard are packaged separately and thus will need to be assembled to the WGLA. A direct mount antenna (either straight or tilt & swivel) can be easily mounted by threading the mating RP-SMA plug of the antenna to the RP-SMA jack on the WGLA. Tighten the connection until finger tight. Then attach the antenna guard by simply threading the guard finger tight onto the threaded base with the RP-SMA connector. A remote mount antenna requires the use of an extension cable to allow the antenna to be mounted in a different location than the WGLA location. The extension cable will need to have one end with a RP-SMA plug connector which will mate with the WGLA connector jack under the same mounting procedure as the direct mount antenna. The other end of the extension cable will need to mate with antenna connector directly. 1.2 Battery Connection Procedure WARNING RISK OF DEATH OR SERIOUS INJURY FROM EXPLOSION OR FIRE Connection and disconnection of the batteries should only be performed in a non-hazardous area. The batteries used in this device may present a risk of fire or chemical burn if mistreated. Do not recharge, disassemble, heat above 100 C 212 F , or incinerate. Failure to comply with these instructions could result in death or serious injury. WARNING RISK OF DEATH OR SERIOUS INJURY FROM EXPLOSION OR FIRE If WGLA is to be returned to Honeywell for any reason, the battery MUST be removed prior to shipping. Dispose of used batteries promptly per local regulations or the battery manufacturers recommendations. Keep away from children. Do not disassemble and do not dispose of in fire. Failure to comply with these instructions could result in death or serious injury. ATTENTION Use only the following 3.6V lithium thionyl chloride (Li-SOCl2) battery (non-rechargeable), size 2/3AA. No other batteries are approved for use in the WGLA Series limit switch. Uniwell, DEV-10-0009 Honeywell, WBT1 Honeywell Sensing and Control 2