HS6E
Solenoid Locking Safety Switches
HS6E Subminiature Interlock Switches with Solenoid
Key features:
Compact body: 75 15 75mm
15mm wide, thinnest solenoid interlock switch in the world
Reversible mounting and angled cable allow four actuator insertion directions
Energy saving: 24V DC, 110mA (solenoid: 100mA, LED: 10mA)
Manual unlocking possible on three sides
LED indicator shows solenoid operation
500N locking retention force
Part Numbers
Mechanical Spring Lock (power solenoid to unlock) Solenoid Lock (remove power to solenoid to unlock)
Cable Cable
Contact Configuration Part Number Contact Configuration Part Number
Length Length
(Actuator inserted) (Solenoid OFF) (Actuator inserted) (Solenoid ON)
(+) () (+) ()
A2 A1 A2 A1
1m HS6E-L7Y4B01-G
1m HS6E-L44B01-G
11 12 41 42
Main Circuit:
11 12 41 42
Main Circuit: 3m HS6E-L44B03-G 3m HS6E-L7Y4B03-G
Monitor Circuit: 21 22 53 54
21 22 5 3 54
Monitor Circuit: 5m HS6E-L7Y4B05-G
5m HS6E-L44B05-G
31 32
Monitor Circuit:
3 1 3 2
Monitor Circuit:
1m HS6E-M44B01-G
1m HS6E-M7Y4B01-G
11 12 41 42
Main Circuit:
3m HS6E-M44B03-G Main Circuit: 11 12 41 42
3m HS6E-M7Y4B03-G
21 22 51 52
Monitor Circuit:
21 22 51 52
5m HS6E-M44B05-G Monitor Circuit:
5m HS6E-M7Y4B05-G
31 32
Monitor Circuit:
31 32
Monitor Circuit:
1m HS6E-N44B01-G 1m HS6E-N7Y4B01-G
11 12 41 42
11 12 41 42 Main Circuit:
Main Circuit:
3m HS6E-N44B03-G 3m HS6E-N7Y4B03-G
21 22 5 3 54
21 22 5 3 54 Monitor Circuit: 11 12 41 42
Monitor Circuit: Main Circuit:
5m HS6E-N7Y4B05-G
5m HS6E-N44B05-G
3 3 34
Monitor Circuit: 21 22 51 52
33 3 4 Monitor Circuit:
Monitor Circuit:
31 32
Monitor Circuit:
1m HS6E-P7Y4B01-G
11 12 41 42
Main Circuit:
1m HS6E-P44B01-G
11 12 41 42
Main Circuit:
3m HS6E-P7Y4B03-G
21 22 5 1 52
Monitor Circuit:
3m HS6E-P44B03-G
21 22 51 52
Monitor Circuit: 5m HS6E-P7Y4B05-G
3 3 3 4
Monitor Circuit:
5m HS6E-P44B05-G
3 3 34
Monitor Circuit:
1. Contact configuration shows the contact status when actuator is inserted and solenoid off for spring lock.
2. Contact configuration shows the contact status when actuator is inserted and solenoid on for solenoid lock.
3. Indicator LED color is green.
4. Actuator keys are not supplied with the interlock switch and must be ordered separately.
11 12 41 42
Main Circuit:
5. Manual unlock key is included with the interlock switch.
21 22 53 54
Monitor Circuit:
6. Standard stock items in bold.
Monitor Circuit: 33 34
11 12 41 42
Main Circuit:
21 22 51 52
Monitor Circuit:
33 34
Monitor Circuit:
1705151128
www.IDEC.com
316
AS-Interface Safety at Work Light Curtains Safety Control Relays Enabling Switches Interlock Switches XW Series E-Stops OverviewOverview XW Series E-Stops Interlock Switches Enabling Switches Safety Control Relays Light Curtains AS-Interface Safety at Work
HS6E
Solenoid Locking Safety Switches
Actuator Keys
Appearance Item Ordering Part Number Remarks
The retention force of HS9Z-A61 actuator is 500N maximum.
Straight Actuator HS9Z-A61
Do not apply excessive load.
The retention force of HS9Z-A62 actuator is 100N maximum.
Right-angle Actuator HS9Z-A62 Do not apply excessive load.
When retention force of 100N or more is required, use the HS9Z-A62S actuator.
Right-angle Actuator The retention force of HS9Z-A62S actuator is 500N maximum.
HS9Z-A62S
with Mounting Plate Do not apply excessive load.
Horizontal/Vertical
Angle Adjustable HS9Z-A65
The HS9Z-A65 and HS9Z-A66 have their metal actuator installed in opposite directions.
Actuator
Select actuator by determining the required moving direction in consideration of the door
and interlock switch.
See page 320 for more information.
Horizontal/Vertical
The retention force of HS9Z-A65 and HS9Z-A66 500N maximum.
Angle Adjustable HS9Z-A66
Actuator
Specifications
UL 508 (UL listed), CSA C22.2, No. 14 (c-UL listed), ISO
14119
Conforming to Standards IEC 60947-5-1, EN 60947-5-1 (TV approval), EN 1088 (TV
approval), GS-ET-19
IEC 60204-1/EN 60204-1 (applicable standards for use)
Operating Temperature 25 to +50C (no freezing)
Storage Temperature 40 to +80C (no freezing)
Operating Humidity 45 to 85% (no condensation)
Rated Insulation Voltage (U ) 300V (between LED and ground: 60V)
i
Main & lock monitor circuits: 1.5 KV
Impulse Withstand Voltage (U ) Door monitor circuit: 2.5 kV
imp
Between solenoid/LED and ground: 0.5 kV
Insulation Resistance Between live and dead metal parts: 100 M minimum
(500V DC megger) Between terminals of different poles: 100 M minimum.
300 m maximum (initial value, 1m cable)
Contact Resistance 500 m maximum (initial value, 3m cable)
700 m maximum (initial value, 5m cable)
Electric Shock Protection Class Class II (IEC 61140)
Pollution Degree 3
Degree of Protection IP67 (IEC 60529)
Operating Extremes 10 to 55 Hz, amplitude 0.35mm
Vibration
Resistance
Damage Limits 30 Hz, amplitude 1.5 mm
2
Operating Extremes 100 m/s (10G)
Shock
Resistance 2
Damage Limits 1000 m/s (100G)
Actuator Operating Speed 0.05 to 1.0 m/s
Direct Opening Travel 8.0 mm minimum
Direct Opening Force 60N minimum
Actuator Retention Force 500N maximum (GS-ET-19)
Operating Frequency 900 operations/hour
Mechanical Life 1,000,000 operations minimum (GS-ET-19)
1705151128
800-262-IDEC (4332) USA & Canada
317