low highest Basic requirements lll unsupported 400 m Travel distance lll none highest Oil resistance fJ noneO 180 Torsion Data cabie I PVC I chainflex CF211 Class 5.5.2.1 Properties and approvals Oil resistance Oil-resistant (following DIN EN 50363-4-1), Class 2. For heavy duty applications -, o1, PVC outer jacket Shielded t. - Flame retardant According to IEC 60332-1-2, CEi 20-35, FT1, W,J-1 Twisted pair Oil-resistant Silicone-free Free from silicone which can affect paint adhesion (following PV 3.1 O. 7 - status 1992). Flame retardant UUCSA Style 10493 and 2464, 300 V, 80 c im.,, Dynamie information NFPA Following NFPA 79-2012 chapter 12.9. Bend radius e-chain linear minimum 7.5 x d G flexible minimum 6 x d Certificate no. RU C-DE.ME .B.01254 (TR ZU) fixed minimum 4 x d lR EAC ( Temperatura e-chain linear +5 C to +70 C CTP Certificate no. C-DE.PB49.B.00416 (Fire safety) e flexible -5 C to + 70 C (following DIN EN 60811-504) fixed -15 c to + 70 C (following DIN EN 50305) CEi Following CEi 20-35. - vmax. unsupported 5m/s gliding 3 m/s Lead-free Following 2011/65/EU (RoHS-II). 2 e amax. 50 m/s c1eanroom According to ISO Class 1. Outer jacket materia complies with CF240.02.24, 9 o:. Travel distance Unsupported travel distances and up to 100 m for gliding applications, Class 5 tested by IPA according to standard 14644-1. Following 2014/35/EU. Cabie structure Conductor Very finely stranded special conductors of particularly bending-resistant design Guarantee made of bare copper wires. Core insulation Mechanically high-quality TPE mixture. Guaranteed lifetime according to guarantee conditions (Page 22-23) ( I Core structure Cores twisted in pairs with a short pitch length, core pairs then wound with Temperatura, R min. factor x d Rmin. factor x d R min. factor x d short pitch lengths. from/to C imus Core identification Colour code in accordance with DIN 47100. +5/+15 10 11 12 +15/+60 7.5 8.5 lntermediate layer Foil taping over the outer layer. +60/+70 10 11 12 < * Higher number of double strokes Online lifetime calculation: www.igus.eu/chainflexlife Overall shield Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70 % inear, approx. 90 % optical Typical mechanical application areas Outer jacket Low-adhesion, oil-resistant PVC mixture, adapted to suit the requirements in For heavy duty applications e-chains (following DIN EN 50363-4-1). Light oil influence lR Colour: Silver-grey (similar to RAL 7001) Preferably indoor applications, but also outdoor ones at temperatures > 5 C Electrical infonnation Unsupported travel distances and up to 100 m for gliding applications G u Nomina voltage 300/300 V (following DIN VDE 0298-3) Storage and retrieval units for high-bay warehouses, machining units/ packaging machines, Handling, indoor cranes Testing voltage 1500 V (following DIN EN 50395) . .... . IO o. .r. CE: ISl lll .... 119 9.5 low highest Basic requirements lll unsupported 400 m Travel distance lll none highest Oil resistance fJ noneO 180 Torsion Data cabie I PVC I chainflex CF211 Class 5.5.2.1 ID io igus chainflex CF211 Example image Part No. Number of cores and conductor Outer diameter Copper Weight nomina cross section d )ma x. index 2 mm mm kg/km kg/km CF21 1.02.01 .02 (2x0.25)C 5.0 17 32 1 CF211.02.02.02 I (2x(2x0.25))C 6.0 24 43 CF211.02.03.02 (3x(2x0.25))C 7.0 34 69 CF211.02.04.02 (4x(2x0.25))C 8.0 42 74 CF211.02.05.02 5x 2x0.25))C 8.5 50 90 CF211.02.06.02 (6x(2x0.25))C 9.0 59 106 CF211.02.08.02 (8x(2x0.25))C 10.5 75 142 CF211.02.10.02 (1 0x(2x0.25))C 12.0 95 174 CF211.02.14.02 (14x(2x0.25))C 12.0 115 196 CF211.03.03.02 (3x(2x0.34))C 8.0 47 84 CF211.03.08.02 (8x(2x0.34))C 11.5 97 174 CF211.03.10.02 (1 0x(2x0.34))C 13.0 119 197 CF21 1.05.Q1 .02 25 (2x0.5)C 5.5 43 2 CF21 1 .05.02.02 1 (2x(2x0.5))C 7.0 39 64 Guarantee CF211.05.03.02 (3x(2x0.5))C 9.0 58 106 CF211.05.04.02 (4x(2x0.5))C 9.5 71 132 CF211.05.05.02 (5x(2x0.5))C 10.5 87 154 CF211.05.06.02 (6x(2x0.5))C 11.5 96 179 CF211.05.08.02 (8x(2x0.5))C 13.0 133 233 CF211.05.10.02 (1 0x(2x0.5))C 15.5 181 295 imus CF211.05.14.02 (14x(2x0.5))C 15.5 200 301 2 The chainflex types marked with l are cables designed as a star-quad. Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core lH G . CE: 120 121