CH - CA and MH - MA enclosures size 104.27 standard version bulkhead mounting housings bulkhead mounting housings inserts: page with 2 levers or 4 pegs with single lever CD .......................... 64 poles + m 45 CT, CTS (10A) ........ 64 poles + m 51 CDD ...................... 108 poles + m 58 CQE ........................ 46 poles + m 77 CN .......................... 24 poles + m 83 CCE ........................ 24 poles + m 92 CNE, CSE................ 24 poles + m 93 CSS ........................ 24 poles + m 101 CTE, CTSE (16A).... 24 poles + m 109 CMSE ........ 10+2 (aux) poles + m 118 CMCE ........ 10+2 (aux) poles + m 118 CX .......................... 4/8 poles + m 133 MIXO ........................ 6 modules 137151 insert centre distance: 104 x 27 mm description part No. part No. with one or two levers CHI 24 CHI 24 L 1) with pegs CHI 24 C 1) with pegs and aluminium cover CHI 24 CS 1) with pegs and plastic cover CHI 24 CP with lever and cover CHI 24 LS 1) May be combined with hoods: dimensions in mm dimensions in mm - CHO/CAO 24 X and CHV/CAV 24 X - MHO/MAO 24 X and MHV/MAV 24 X CHI CHI L N.B.: the enclosures ensure IP66 protection (or IP65 76.5 59 179.5 cover versions) rating when mated and locked with the closing levers. The cover (CS, CP) only ensures mechanical protection, but does not ensure IP65 protection rating. 29 29 panel cut-out for bulkhead mounting housings in mm 45.5 142.5 45.5 142.5 6 6 4.5 CHI C CHI LS 97 112 130 29 142.5 45.5 6 29 142.5 45.5 6 32 CHI CS/CP 35 74 29 142.5 45.5 6 Type E 4/4X/12 (excluding enclosures with plastic cover) dimensions indicated are not binding and may be changed without notice 212 size 104.27size 104.27 CH - CA and MH - MA enclosures size 104.27 standard version surface mounting housings surface mounting housings inserts: page with 2 levers or 4 pegs with single lever CD .......................... 64 poles + m 45 CDD ...................... 108 poles + m 58 CQE ........................ 46 poles + m 77 CN .......................... 24 poles + m 83 CCE ........................ 24 poles + m 92 CNE, CSE................ 24 poles + m 93 CSS ........................ 24 poles + m 101 CMSE ........ 10+2 (aux) poles + m 118 CMCE ........ 10+2 (aux) poles + m 118 CX .......................... 4/8 poles + m 133 MIXO ........................ 6 modules 137151 insert centre distance: 104 x 27 mm description part No. entry part No. entry part No. entry part No. entry Pg M Pg M with levers CHP 24 21 MHP 24.25 25 CHP 24 L 21 MHP 24 L25 25 with levers CHP 24.2 21 x 2 MHP 24.225 25 x 2 CHP 24 L2 21 x 2 MHP 24 L225 25 x 2 with levers, high construction CAP 24.21 21 MAP 24.32 32 CAP 24 L 21 MAP 24 L32 32 with levers, high construction CAP 24.221 21 x 2 MAP 24.232 32 x 2 CAP 24 L2 21 x 2 MAP 24 L232 32 x 2 with levers, high construction CAP 24.29 29 MAP 24.40 40 CAP 24 L29 29 MAP 24 L40 40 with levers, high construction CAP 24.229 29 x 2 MAP 24.240 40 x 2 CAP 24 L229 29 x 2 MAP 24 L240 40 x 2 1) with pegs and aluminium cover CHP 24 CS 21 MHP 24 CS25 25 1) with pegs and aluminium cover CHP 24 CS2 21 x 2 MHP 24 CS225 25 x 2 1) with pegs and aluminium cover, high construction CAP 24 CS 21 MAP 24 CS32 32 1) with pegs and aluminium cover, high construction CAP 24 CS2 21 x 2 MAP 24 CS232 32 x 2 1) with pegs and aluminium cover, high construction CAP 24 CS29 29 MAP 24 CS40 40 1) with pegs and aluminium cover, high construction CAP 24 CS229 29 x 2 MAP 24 CS240 40 x 2 1) with pegs and plastic cover CHP 24 CP 21 MHP 24 CP25 25 1) with pegs and plastic cover CHP 24 CP2 21 x 2 MHP 24 CP225 25 x 2 1) with pegs and plastic cover, high construction CAP 24 CP 21 MAP 24 CP32 32 1) with pegs and plastic cover, high construction CAP 24 CP2 21 x 2 MAP 24 CP232 32 x 2 1) with pegs and plastic cover, high construction CAP 24 CP29 29 MAP 24 CP40 40 1) with pegs and plastic cover, high construction CAP 24 CP229 29 x 2 MAP 24 CP240 40 x 2 with lever and cover CHP 24 LS 21 MHP 24 LS25 25 with lever and cover CHP 24 LS2 21 x 2 MHP 24 LS225 25 x 2 with lever and cover, high construction CAP 24 LS 21 MAP 24 LS32 32 with lever and cover, high construction CAP 24 LS2 21 x 2 MAP 24 LS232 32 x 2 with lever and cover, high construction CAP 24 LS29 29 MAP 24 LS40 40 with lever and cover, high construction CAP 24 LS229 29 x 2 MAP 24 LS240 40 x 2 1) May be combined with hoods: dimensions in mm dimensions in mm - CHO/CAO 24 X and CHV/CAV 24 X CHP - CAP and MHP - MAP CHP L - CAP L and MHP L - MAP L - MHO/MAO 24 X and MHV/MAV 24 X 74 179.5 59 N.B.: the enclosures ensure IP66 protection (or IP65 cover versions) rating when mated and locked with the closing levers. The cover (CS, CP) only ensures mechanical protection, but does not ensure IP65 protection rating. 5.5 A A 5.5 Pg/M Pg/M Pg/M Pg/M 45 4 132 4 132 45 144 57 57 144 CHP CS/CP - CAP CS/CP and MHP CS/CP - MAP CS/CP CHP LS - CAP LS and MHP LS - MAP LS 97 74 A 5.5 A 5.5 Pg/M Pg/M Pg/M Pg/M Type 132 45 4 4 132 45 E 4/4X/12 57 144 57 144 (excluding enclosures with plastic cover) type A type A CHP / MHP 63 CHPL/ MHPL 63 CAP / MAP 81 CAPL/ MAPL 81 CHP CS / MHP CS 63 CHP LS / MHP LS 63 CAP CS / MAP CS 81 CAP LS / MAP LS 81 CHP CP / MHP CP 63 dimensions indicated are not binding CAP CP / MAP CP 81 and may be changed without notice 213