Isolaaators 69Series 3 and 4 pole On load 20A - 100A Red/yellow or black handles 3 padlock positions IP65 Enclosed, DIN rail, base or panel mount versions Lightweight exxxt shafts 100-400mm Side mounted auxiliary contacts UL approval Options and ordering codes 20 PM69 - 30 RY64 IP65 enclosed PE69 3 pole 30 RY48 Direct red/yellow 48mm handle Rating 400V AC21/Amps AC23/kW Base mount door interlock LB69 4 pole 40 RY64 Direct red/yellow 64mm handle Front panel mount PM69 20 5.5 B48 Direct black 48mm handle 60 8 ppole 80 Direct handle base mounted DM69 25 7.5 B64 Direct black 64mm handle 32 11 Enclosed/door interlocked vertical 40 15 63 18.5 80 22 100 37 Accessories Description Part ref Red/yellow handle 64 x 64mm H69-0001 Black handle 64 x 64mm H69-0002 Red/yellow handle 48 x 48mm H69-0003 Black handle 48 x 48mm H69-0004 Door handle mounting tool J7049 Exxxtension shaft 100mm E69-0001 Exxxtension shaft 200mm E69-0002 Exxxtension shaft 300mm E69-0003 Exxxtension shaft 400mm E69-0004 Auxiliary contacts 1 n/o + 1 n/c A69-0001 Auxiliary contacts 2 n/o A69-0002 Solid neutral block SN69-0001 Add on neutral switching pole 20-40A SP69-0001 Auxiliary contacts 1 n/o + 1 n/c A69-0001 Auxiliary contacts 2 n/o only A69-0002 69Series/11/12 wwwwwwwww.imopc.comIsolaaators 69 Series continued Technical Data Data according to IEC 947-3, IEC 947-5-1, VDE 0660, EN 60947-3, EN 60947-5-1 ..69..20 ..69..25 ..69..32 ..69..40 ..69..63 ..69..80 ..69..100 Type Main contacts Rated thermal current I open A 20 25 32 40 63 80 100 th Rated thermal current I enclosed A 20 25 32 40 63 80 100 thethe 1) 5) Rated insulation voltage U V 690 690 690 690 690 690 1000 i Rated operational current I AC21A A 20 25 32 40 63 80 100 e Making capacity I 3x220-440V A 160 190 220 300 370 440 725 effeff Breaking capacity 3x380-440V A 160 180 200 250 330 380 580 3x660-690V A 160 180 200 250 330 380 580 A 80 110 140 170 190 220 330 Disconnection property performed up to V 690 690 690 690 690 690 1000 Motor Switch AC3 3x400V A 12 16 23 30 37 37 60 Motor Switch AC3 3x220-240V kW 3 4 5,5, 7,5, 11 11 18,,5 Direct switching of single motors 3x380-440V kW 5,5, 7,5, 11 15 18,,5 18,,5 30 3x660-690V kW 5,5, 7,5, 11 15 18,5, 18,5, 22 Main Switch AC23 3x400V A 16 20 25 32 45 45 72 Motor Switch, AC23A 3x220-240V kW 4 5,5, 7,5, 9 15 15 22 Main Switch, AC23B 3x380-440V kW 7,5, 10 12,5, 16 22 22 37 Safety Switch 3x660-690V kW 5,5, 7,5, 11 15 18,5, 18,5, 30 Rated conditional short-circuit current kA 10 10 10 10 10 10 10 eff Max. fuse size gL (gG) A 25 35 40 50 63 80 100 3 Mechanical life x10 200 200 200 200 100 100 100 Rated short-time withstand current (1 sec. current) A 250 300 400 500 600 850 1200 Maximum ambient temperature o o Operation Open -40 C to +60 C o o enclosed -40 C to +40 C o o storage -50 C to +90 C 2 Cable cross sections 1 - 25 mm 0,,5 -10 4 - 50 solid or standard 16 - 4 (10) AWG 20 - 8 (10)() 10 - 0 ()(10) 2 flexible 4 - 16 mm 0,5 - 6 10 - 35 16 - 6 AWG 20 - 10 8 - 2 2 flexible (+ multicore cable end) 0,75 - 16 mm 0,,5 - 6 6 - 35 16 - 6 AWG 20 - 10 8 - 2 Size of terminal screw M5 M3,,5 M6 Tightening torque 2 - 4 Nm 0,,,8 - 1,7 3,5 - 4,5 Auxillary contacts 1) Rated insulation voltage U 690 V 690 690 i Rated thermal current I , I 10 A 10 10 th the Switching capacity AC15 220-240V 2,5 A 2,5, 2,5 AC15 380-440V 1,5 A 1,5, 1,5 Rated conditional short-circuit current 3 kA 3 3 eff Max. short circuit protection gL (gG) 10 A 10 10 2 Cable cross sections 0,75 - 2,5 mm 0,,,75 - 2,5 0,75 - 2,5 Solid or standard 14 - 12 AWG 14 - 12 14 - 12 2 flexible (+ multicore cable end) 0,75 - 2,5 (1,5) mm 0,75 - 2,5 (1,5), , (,) 0,75 - 2,5 (1(),5) 18 - 14 AWG 18 -14 18 - 14 Data according to UL and cUL Type ..69..20 ..69..25 ..69..32 ..69..40 ..69..63 ..69..80 ..69..100 Rated voltage 600 600 600 600 V 600 600 600 Ampere-Rating General use 32 40 80 100 A 20 25 63 DOL-Rating 3-phase 110-120V 2 2 5 10 HP 1 1,5 3 220-240V 5 5 10 25 HP 3 5 10 440-480V 10 10 20 50 HP 7,5 10 20 550-600V 15 15 25 60 HP 10 10 25 DOL-Rating 1-Phase 110-120V 1 1 2 5 HP 1 1 2 200-208V 2 2 3 10 HP 1 2 3 220-240V 3 3 5 15 HP 2 2 5 Fuse size (RK5) Manual Motor Controller 50 70 110 125 A 40 50 90 5kA / 600V Motor Disconnect 50 50 70 125 A 40 50 70 Tightening torque 1,2,, - 2,3 1,2,, - 2,3 2,8, - 4 1,,,7 - 4,5 Nm 1,2 - 2,3,, 1,2 - 2,3,, 2,8 - 4, 11 - 20 11 - 20 24 - 35 15 - 40 Ib.inch 11 - 20 11 - 20 24 - 35 1) Suitable for: earthed-neutral systems, overvoltage category I to III, pollution degree 3 (standard-industry): Uimp = 6kV. Data for other conditions on request 69Series/11/12 wwwwwwwww.imopc.com