High Capacity Relay HY 3mm contact gap as standard 30A high capacity relay able to withstand momentary voltage drops to 50% rated Class F insulation Heavy load up to 7500VA UL/cUL approved Options and ordering codes HY--1A 1- 200/240VAC Power Relay For coil voltage see table Single pole double make 1A Double pole double make 2A 1 Solder Lug/push-on 2 PCB (2A version only) Specification Type HY1A HY2A Rated load Res. 30A, 250VAC/Ind. 25A,. 250VAC COS 0.4 Res. 25A, 250VAC/Ind. 25A, 250VAC COS 0.4 Rated current 30A 25A Maximum switching voltage 277VAC Maximum switching capacity 7500VA 6250VA Operate time 30ms max Release time 30ms max Dielectric strength 4000V, 50/60Hz for 1 min (coil to contact) Ambient operating temperature -55~+70C (no freezing) Mechanical service life 10,000,000 operations min Electrical service life 100,000 operations min Contact material AgSnO Voltage range AC80~110%, DC75~110% Power consumption Approx. 1.7VA~2.7VA/1.9W Weight Approx. 120g Coil Data Rated AC Coils. DC Coils. Volatge Coil resistance Coil resistance 12 75 75 24 300 300 100/120 5200 6300 200/240 208000 - HY/02/05 www.imopc.com10.4 36 0.8 High Capacity Relay HY continued Outline dimensions (mm) 51.5 40 40 4.5 36.4 36.4 0.8 14.4 6.35 PCB layout Wiring diagram 2A 1A 2A 12 3 4 14 14.4 65 65 1.1x3.3 - 6 36.4 Tolerance: 0.1 Mounting holes 4.50.1 - 2 or M4 Tapped holes 400.1 HY/02/05 www.imopc.com 8.0 34.9 17.7