Installation Instructions for CS Series PK 8791 4 Linear Current Sensor Holder Assemblies GENERAL INFORMATlON SOLDERING INSTRUCTIONS meter/min.). Select a speed which gives full CS Series current sensor holder assem- Hand Soldering - Use 60/40 rosin core solder fillets and minimum of bridging and blies have a single linear output that will solder, employing a 399C (750F) icicles. The printed circuit board requires source current. The output voltage, which is controlled temperature, 1/8 chisel tip rigid support during wave soldering. ratiometric, varies in direct proportion to the soldering iron. To avoid delamination of the supply voltage. (Refer to Catalog 20 for terminals from the ceramic, do not hold the CLEANING more information). These sensors will not Proper cleaning fluids should be selected iron on the terminals for more than four be damaged by overcurrent in the sensed seconds. The temperature of the lead at the based on the type of contaminants to be conductor. removed. HONEYWELL recommends ceramic conductor interface must not exceed 250C (482F). alcohols, chlorinated solvents, and NORMAL MOUNTlNG fluorinated solvents. Bottom mount version: Wave Soldering - Use Loncoflux 106A35 0.375 inch long 4-40 screw and a square or equivalent. Preheaters should be set for nut (not provided) inserted in the housing. 95C (200F) on top (component side) of Electrical- Do not exceed maximum supply Side mount version: printed circuit board just prior to board ratings. Do not reverse supply voltage 0.250 inch long 6-32 screw and a square polarity. entering wave. (This may have to be nut (not provided) inserted in the housing. adjusted depending upon board thickness.) Handling -The terminals are fragile. Handle with care. Solder temperature should be a maximum Dielectric Isolation- The toroidal cores are of 260C (500F), preferably 252C to 260C (485F to 500F). Set conveyor speed to conductive. The user must provide the approximately 4.5 feet per minute (1,37 necessary dielectric isolation. MOUNTING DIMENSIONS (for reference only) WARRANTY/REMEDY Seller warrants its products to be free from defects in design, incidental, or punitive damages attributable to negligence or strict material and workmanship under normal use and service. Seller will liability, all by way of example. repair or replace without charge any such product it finds to be so defective on its return to Seller within 18 months after date of For application assistance, current specifications or technical help, shipment by Seller. The foregoing is in lieu of all other ex- call toll free 800/537-6945. pressed or implied warranties (except of title), including those of merchantability and fitness for a particular purpose. The While we provide assistance on HONEYWELL products, foregoing is also purchaser s sole remedy and is in lieu of all other personally and through our literature, it is up to the customer to guarantees, obligations, or liabilities or any consequential, determine the suitability of the product in the application. Honeywell Sensing & ControlPK 87914 CS Series Linear Current Sensor Holder Assemblies OPERATING CHARACTERISTICS BOTTOM MOUNT WITH 9SS (LOHET I) SENSOR Core Mtg. Sensed Offset Temp. Offset Response Supply Supply Catalog Dim. Voltage Current Current* Voltage Range Shift Time Gap Listing Fig. (mA max.) (Amps-Peak) (V 10%) C (%/C) (in.) (S) (DC) CSLA1CD 0.075 1 8 to 16 19 57 Vcc/2 -25 to +85 0.05 3 CSLA1CE 0.094 8 to 16 19 75 Vcc/2 -25 to +85 0.05 3 1 CSLA1DE 0.094 2 8 to 16 19 75 Vcc/2 -25 to +85 0.05 3 CSLA1CF 0.125 1 8 to 16 19 100 Vcc/2 -25 to +85 0.05 3 CSLA1DG 0.149 2 8 to 16 19 120 Vcc/2 -25 to +85 0.05 3 CSLA1CH 0.188 1 8 to 16 19 150 Vcc/2 -25 to +85 0.05 3 CSLA1DJ 0.276 2 8 to 16 19 225 Vcc/2 -25 to +85 0.05 3 CSLA1EJ 0.05 3 0.276 3 8 to 16 19 225 Vcc/2 -25 to +85 0.05 3 CSLA1DK 0.375 2 8 to 16 19 325 Vcc/2 -25 to +85 0.05 3 CSLA1EK 0.375 3 8 to 16 19 325 Vcc/2 -25 to +85 0.05 3 CSLA1EL 0.590 3 8 to 16 19 625 Vcc/2 -25 to +85 BOTTOM MOUNT WITH SS9 (LOHET II) SENSOR Offset Response Core Mtg. Sensed Offset Temp. Supply Supply Catalog Shift Time Dim. Voltage Current Current* Voltage Range Gap (%/C) Listing Fig. (mA max.) (Amps-Peak) (V 2%) C (in.) (DC) (S) CSLA2CD -25 to +85 0.02 3 0.075 1 6 to 12 20 72 Vcc/2 -25 to +85 0.02 3 CSLA2CE 0.094 1 6 to 12 20 92 Vcc/2 -25 to +85 0.02 3 CSLA2DE 0.094 2 6 to 12 20 92 Vcc/2 0.02 3 CSLA2CF 0.125 1 6 to 12 20 125 Vcc/2 -25 to +85 0.02 3 CSLA2DG 0.149 2 6 to 12 20 150 Vcc/2 -25 to +85 CSLA2DH -25 to +85 0.0125 3 0.125 2 6 to 12 20 235 Vcc/2 CSLA2DJ 0.266 2 6 to 12 225 Vcc/2 -25 to +85 0.02 3 20 CSLA2EJ 0.160 3 6 to 12 20 310 Vcc/2 -25 to +85 0.0125 3 CSLA2DK 0.210 2 6 to 12 20 400 Vcc/2 -25 to +85 0.0125 3 CSLA2EL 0.276 3 6 to 12 20 550 Vcc/2 -25 to +85 0.0125 3 CSLA2EM 0.160 3 6 to 12 20 765 Vcc/2 -25 to +85 0.008 3 CSLA2EN 0.210 3 6 to 12 20 950 Vcc/2 -25 to +85 0.008 3 SIDE MOUNT WITH 9SS (LOHET I) SENSOR Core Mtg. Sensed Offset Temp. Offset Response Supply Supply Catalog Dim. Voltage Current Current* Voltage Range Shift Time Gap Listing Fig. (mA max.) (Amps-Peak) (V 10%) C (%/C) (in.) (DC) (S) CSLA1GD 0.075 4 8 to 16 19 57 Vcc/2 -25 to +85 0.05 3 CSLA1GE 0.094 4 8 to 16 19 75 Vcc/2 -25 to +85 0.05 3 CSLA1GF 0.125 4 8 to 16 19 100 Vcc/2 -25 to +85 0.05 3 SIDE MOUNT WITH SS9 (LOHET II) SENSOR Core Mtg. Sensed Offset Temp. Offset Response Supply Supply Catalog Dim. Voltage Current Current* Voltage Range Shift Time Gap Listing Fig. (mA max.) (Amps-Peak) (V 2%) C (%/C) (in.) (DC) (S) CSLA2GD 0.075 4 6 to 12 20 72 Vcc/2 -25 to +85 0.02 8 CSLA2GE 0.094 4 6 to 12 20 92 Vcc/2 -25 to +85 0.02 8 CSLA2GF 0.125 4 6 to 12 20 125 Vcc/2 -25 to +85 0.02 8 CSLA2GG 0.149 4 6 to 12 20 150 Vcc/2 -25 to +85 0.02 8 NOTE: When monitoring purely AC current with zero DC component, a capacitor can be inserted in series with the output of the current sen- sor. The capacitor will block out the effect of the temperature variation of the offset voltage which increases the accuracy of the device. Honeywell Sensing & Control Helping you control your world PK 87914 293 Printed in USA