SPECIFICATIONS: LINEAR POWER SUPPLY IP500U12 MADE IN THE U.S.A. VAC JUMPERING AND FUSING REQUIREMENTS: VAC INPUT: SILKSCREENED ON CHASSIS FOR TRANSFORMER PRIMARY TERMINALS 120/240VAC, +/-10% (PRIMARY TAPS PROVIDED) USE AT: 108VAC 120VAC 132VAC 216VAC 240VAC 264VAC FREQUENCY RANGE: 47-63HZ Jumper 1&5,2&6 1&5,3&7 1&5,4&8 2&5 3&5 4&5 Apply AC 1&2 1&3 1&4 1&7 1&7 1&8 MaxCurrent/FuseRating 6A 6A 6A 3A 3A 3A CAUTION NOT TO BE USED WITH IEC127 STYLE FUSE. USE ONLY AMERICAN AGC TYPE OVERVOLTAGE PROTECTION: UNREGULATED VDC OUT NOMINAL LINE PROVIDED. FACTORY SET AT 6.2 VDC +/- 0.4 VDC 12.5 VDC 30 AMP (FULL LOAD) SHORT CIRCUIT PROTECTION: 13.3 VDC HALF LOAD 15.0 VDC 0 AMP OUTPUT FUSED 25 AMP OVERLOAD PROTECTION: DC CONNECTIONS: AUTOMATIC CURRENT LIMIT +OUT 0.250x0.032 FAST-ON AT FUSE BLOCK -OUT (DC RETURN) SOLDER TERMINAL MINUS SIDE OF THE CAPACITOR LINE REGULATION: LOAD REGULATION NOMINAL LINE EQUAL TO % LINE CHANGE 9% FOR A 50% TO 100% LOAD CHANGE (DERATE OUTPUT CURRENT 10% FOR 58 HZ OPERATION) OUTPUT RIPPLE: 3.0 VDC PK-PK MAXIMUM MTBF: 1,800,000 HRS. CALCULATED PER MIL-HDBK-217F/25 C/GROUND BENIGN TEMPERATURE RATINGS: EMI/RFI: INHERENT LOW CONDUCTED AND REDIATED NOISE LEVELS. OPERATING: 0 C TO 55 C FULL RATED EMI: FCC CFR TITLE 47 PART 15 SUB-PART B DERATED LINEARLY TO 40% 70 C RFI: EN55022/CISPR22-LEVEL B COMPATIBILITY STORAGE: -40C TO + 95 C VIBRATION: SHOCK: MIL-STD-810G, METHOD 514.6, CATEGORY 1, MIL-STD-810G, METHOD 516.6, PROCEDURE III PROCEDURE1 OPERATING: 20 GPK RANDOM VIBRATION 10Hz - 2KHz, 6.15 grams (3 axis) EFFICIENCY (TYPICAL): 75% TO 80% FULL LOAD UL recognized for US and Canada File E133338/ CE Mark: LVD 92/59/EEC/ RoHs-5 Lead in Solder Exemption US and Canadian(Bi-National) standards: ANSI/UL 60950-1/-21 CAN/CSA C22.2 60950-1/-21 IEC 60950-1 CASE SIZE: IP500U