DrivingtheLightingRevolution EUC-150SxxxDVA(SVA) Rev. A Features Constant Current Output Ultra High Efficiency (Up to 93%) Active Power Factor Correction (0.99 Typical) Compact Package Design Dimming Control Lightning Protection All-Around Protection: SCP, OTP, OVP Waterproof IP67 SELV Description The EUC-150SxxxDVA(SVA) series operates from a 90 ~ 305 Vac input range. They are designed to be highly efficient and highly reliable. The standard features include dimming control, lightning protection, over voltage protection, short circuit protection, and over temperature protection. Models Input Output Max. Typical Power Factor Output Model Number Voltage Voltage Output Efficiency Current (3) 120Vac 220Vac Range(1) Range Power (2) 530 mA 90 ~ 305 Vac 142~283Vdc 150 W 93.0% 0.99 0.95 EUC-150S053DV(SV)A 700 mA 90 ~ 305 Vac 107~214Vdc 150 W 92.5% 0.99 0.95 EUC-150S070DV(SV)A 1050 mA 90 ~ 305 Vac 71~142Vdc 150 W 92.0% 0.99 0.95 EUC-150S105DV(SV)A 1400 mA 90 ~ 305 Vac 53~107Vdc 150 W 91.0% 0.99 0.95 EUC-150S140DV(SV)A(4) 2100 mA 90 ~ 305 Vac 36~71.5Vdc 150 W 91.0% 0.99 0.95 EUC-150S210DV(SV)A(4) 2450 mA 90 ~ 305 Vac 31~61.2Vdc 150 W 91.0% 0.99 0.95 EUC-150S245DV(SV)A(4) 2800 mA 90 ~ 305 Vac 27~53.5Vdc 150 W 91.0% 0.99 0.95 EUC-150S280DV(SV)A(4) 3150 mA 90 ~ 305 Vac 24~47.5Vdc 150 W 91.0% 0.99 0.95 EUC-150S315DV(SV)A(4) Notes: (1) Certificated input Voltage range100-240Vac. (2) Measured at full load and 220 Vac input. (3) A suffix xxxx may be added to denote variations or modifications to the standard product, where x can be any alphanumeric character or blank. (4) SELV Output. Input Specifications Parameter Min. Typ. Max. Notes Input Voltage 90 V - 305 V Input Frequency 47 Hz - 63 Hz Leakage Current - - 1 mA At 277Vac 60Hz input Specifications are subject to changes without notice. www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales inventronics-co.com DrivingtheLightingRevolution EUC-150SxxxDVA(SVA) Rev. A Input Specifications (Continued) Parameter Min. Typ. Max. Notes - - 1.8 A Measured at full load and 100Vac input. Input AC Current - - 0.9 A Measured at full load and 220Vac input. Inrush current - - 75 A At 220Vac input, 25 cold start, duration=1.7 2 2 ms, 10%Ipk-10%Ipk. Inrush current(I t) - - 3.5 A s PF 0.90 - - At 100Vac-277Vac, 75%load-100%load THD - - 20% Output Specifications Parameter Min. Typ. Max. Notes Output Current Tolerance -5% 5% No-load Output Voltage 300V I = 530 mA 291V 309V O 225V I = 700 mA 218V 236V O I = 1050 mA 150V 155V 160V O I = 1400 mA 112V 115V 118V O I = 2100 mA 77V 80V 82V O IO = 2450 mA 67V 69V 71V I = 2800 mA 58V 62V O 60V I = 3150 mA 50V 54V O 52V Output Current Ripple (pk- - 10%Io 15%Io At full load condition. pk) Output Current Overshoot / - 8% 10% At full load condition. Undershoot Line Regulation - - 1% Load Regulation - - 3% - 1.0 s 2.0 s Measured at 120Vac input. Turn-on Delay Time - 1.0 s 2.0 s Measured at 220Vac input. Temperature coefficient - - 0.03%/ C Case temperature = 0C ~Tc max Note: All specifications are typical at 25 C unless stated otherwise. Protection Functions Parameter Notes No damage should occur due to any output operating under a short circuit condition. The Short Circuit Protection power supply will self-recover once the fault condition is removed. Decrease output current mode. When the case temperature reaches 120 10, the output Over Temperature Protection current decreases to 50%Io until the case temperature reaches 75. Specifications are subject to changes without notice. www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales inventronics-co.com