ELPAC FWA020 SERIES CLASS I 20 Watt ITE Desktop Power Supply Safety Approval - EN60950-1 Class I High Efficiency: Level VI Hold-up Time >16ms at full load Fully Regulated DC output EuP Directive Compliant LED Indicator 5-Year Limited Warranty 1 2 3 Model Number Output Voltage Output Current Peak Current Total Regulation Typical Efficiency FWA020012A-10A 12.0V 1.6A 1.9A 5% 88.4% FWA020015A-10A 15.0V 1.3A 1.6A 5% 88.4% FWA020018A-10A 18.0V 1.1A 1.3A 5% 88.1% FWA020024A-10A 24.0V 0.8A 1.0A 5% 87.8% Notes 1) Maximum peak load (21W) lasting 500ms with a maximum 10% duty cycle. 2) Includes initial setting, line regulation, load regulation, and thermal drift. 3) Typical at 115VAC INPUT OUTPUT 85 264VAC Output Voltage See Table Input Voltage 100 240VAC Nominal Total Regulation +/-5% Input Frequency 47 63Hz Minimum Load No minimum load required Input Current <1.0A rms Start-Up Delay <2.0s Inrush Current <60A at 230VAC cold start Hold-Up Time >16ms at any input voltage Zero Load <0.1W Power Consumption Ripple & Noise <1% pk-pk ** <100A 132VAC 60Hz Earth Leakage Current Over Voltage Protection 112 135% (Typical) <150A 264VAC 60Hz Over Temperature First Stage - Recoverable plus Protection 2nd stage - Non Recoverable Over Current Protection 108 180% Short Circuit Protection Shutdown, auto-restart (hiccup mode) Notes **Ripple and noise measured with 20MHz bandwidth 10F tantalum capacitor in parallel with a 0.1F ceramic capacitor. Inventus Power Inventus Power Technical Support: 1200 Internationale Parkway Woodridge, IL 60517, USA powersupplies inventuspower.comELPAC FWA020 SERIES - CLASS I 20 Watt ITE Desktop Power Supply General Environmental EMC & Safety 0 60C (Full load to 40C, FCC class B, CISPR22 Operating Emissions Avg. Efficiency 90.7% Efficiency derate linearly to 50% load at class B EN6100-3-2, 3 Temperature 115VAC 89.8% 230VAC 60C) EN61000-4-2, -3, -4, -5, -6, -8, Immunity Storage -11 min. 200,000 hours -40C to +85C MTBF Temperature demonstrated cTUVus Relative 5-95%, non-condensing UL 606950-1 3.53 (89.6mm) x 1.92 Humidity Size (48.4mm) x 1.00 (25.2mm) CAN/CSA-22.2 No.950 Certified by Cooling Natural Convection TUV to the CB per IEC60950-1 2nd edition All units production tested to Weight 0.3 lbs (0.16 Kg) following: Vibration 2 19.6m/s CE marked to LVD directive and Altitude 3 Power Density 2.95W/in RoHS II directive Rated to 5000M (Operating) Input Configuration Output Configuration Output Pin Assignments Standard Center +V1 Standard 4ft Not Provided Output Cable Input Cable Outside Return Connection on Cord Size 2x16awg zip Power Supply IEC 320 C6 Receptacle Body Connector Switchcraft 760 or equivalent (PSU side) Mating Switchcraft 760 or equivalent Connector Mechanical Drawing Inventus Power IP DS FWA020-I 9-9-16 01 1200 Internationale Parkway inventuspower.com Woodridge, IL 60517, USA 2016 Inventus Power, All rights reserved.