IS6005, IS6010, IS6015 OPTICALLY COUPLED BILATERAL SWITCH NON-ZERO CROSSING TRIAC Dimensions in mm APPROVALS 2.54 z UL recognised, File No. E91231 under Package System KK 1 6 7.0 6.025 X SPECIFICATION APPROVALS 3 4 z z z VDE 0884 in 3 available lead forms : - z z 1.2 - STD - G form 7.62 7.62 6.62 - SMD approved to CECC 00802 4.0 3.0 13 0.5 DESCRIPTION Max 3.0 0.26 The MOC302 series are optically coupled 3.35 0.5 isolators consisting of a Gallium Arsenide infrared emitting diode coupled with a light activated silicon bilateral switch performing the ABSOLUTE MAXIMUM RATINGS functions of a triac mounted in a standard 6 pin (25 C unless otherwise noted) dual-in-line package. 0 0 Storage Temperature -55 C - +150 C FEATURE 0 0 Operating Temperature -40 C - +100 C 0 Lead Soldering Temperature 260 C z Options :- (1.6mm from case for 10 seconds) 10mm lead spread - add G after part no. Surface mount - add SM after part no. Tape&reel - add SMT&R after part no. INPUT DIODE z High Isolation Voltage (5.3kV ,7.5kV ) RMS PK z 400V Peak Blocking Voltage Forward Current 50mA z All electrical parameters 100% tested Reverse Voltage 6V z Custom electrical selections available Power Dissipation 70mW 0 0 (derate linearly 0.93mW/ C above 25 C) APPLICATIONS z CRTs OUTPUT PHOTO TRIAC z Power Triac Driver z Motors Off-State Output Terminal Voltage 400V z Consumer appliances Forward Current (Peak) 1A z Printers Power Dissipation 300mW 0 0 OPTION G OPTION SM (derate linearly 4.0mW/ C above 25 C) SURFACE MOUNT 7.62 POWER DISSIPATION 0.6 Total Power Dissipation 330mW 1.25 0.26 0.1 0 0 (derate linearly 4.4mW/ C above 25 C) 0.75 10.46 10.16 9.86 ISOCOM COMPONENTS 2004 LTD Unit 25B, Park View Road West, Park View Industrial Estate, Brenda Road Hartlepool, Cleveland, TS25 1UD Tel: (01429) 863609 Fax :(01429) 863581 27/11/08 DB91045ELECTRICAL CHARACTERISTICS ( T = 25C Unless otherwise noted ) A PARAMETER MIN TYP MAX UNITS TEST CONDITION Input Forward Voltage (V ) 1.2 1.5 V I = 10mA F F Reverse Current (I ) 100 AV = 6V R R Output Peak Off-state Current ( I ) 100 nA V = 400V (note 1 ) DRM DRM Peak Blocking Voltage ( V ) 400 V I = 100nA DRM DRM On-state Voltage ( V ) 1.5 3.0 V I = 100mA ( peak ) TM TM Critical rate of rise of off-state Voltage ( dv/dt ) ( note 1 ) 10 V/s Critical rate of rise of commutating Voltage ( dv/dt ) ( note 1 ) 0.1 0.2 V/s I load = 15mA, V = 30V ( fig 1. ) IN Coupled Input Current to Trigger ( I )(note 2 ) FT IS6015 15 mA V = 3V ( note 2 ) D IS6010 10 mA IS6005 5 mA MOC3023 Holding Current , either direction ( I ) 100 A H Input to Output Isolation Voltage V 5300 V See note 3 ISO RMS 7500 V See note 3 PK Note 1. Test voltage must be applied within dv/dt rating. Note 2. Guaranteed to trigger at an I value less than or equal to max. I , recommended I lies F FT F between Rated I and absolute max. I . FT FT Note 3. Measured with input leads shorted together and output leads shorted together. FIGURE 1 +5v V V R CC CC 1 6 IN + V IN 120 2 5 - 0v ~ R L 3 4 COMMUTATING STATIC 2k dv/dt dv/dt 27/11/08 DB91045m-AAS/A5