SMA 50 Ohm Reverse Polarity Straight Crimp Type Plug - INCHES (MILLIMETERS) CUSTOMER DRAWINGS AVAILABLE UPON REQUEST Solder or Crimp Captivated Contact CABLE TYPE GOLD PLATED NICKEL PLATED RG-58/U, 141, 303 142-4407-001 142-4407-006 1. Identify connector parts. (3 piece parts - except bulkhead) 2. Strip cable to dimensions shown. Do not nick braid or center conductor. Tin center conductor if contact will be solder attached. Do not tin center conductor if contact is to be crimp attached. When stripping LMR-100 low loss cable, remove foil back to where cabl e jacket is stripped. A wire stripper of correct size is recommended for this step. Slide heat shrink (as applicable) and crimp sleeve onto jacket of cable. 3. Assemble contact onto cable as shown. Solder Attachment: Solder contact to center conductor through solder hole using .020 (0.51) diameter solder. Use a minimum amount of solder for a good joint. TM Crimp Attachment: Crimp contact to center conductor using Johnson Components Hand Tool 144-0000-910, setting 2, with positioner 141-0000-907. Crimp location should be centered between end of contact and X-hole. Crimp attachment to solid cente r conductor cables is not recommended. 4. Flare braid and slide body assembly over contact and under braid. Then seat body assembly firmly onto contact. The cable may have to be held in a clamping fixture. Arrange braid uniformly around crimp stem. Slide crimp sleeve forward and crimp using recom mended crimp tool. Slide heat shrink forward and shrink (as applicable). CABLE GROUP PART NUMBER CRIMP HEX RG-58/u, 141, 303 142-4407-001/006 .213 (5.41) CCinincch Ch Coonnnnecectitivitvity Soy Solulutitioonsns 299 J299 Johnsohnson Aon Avveennue Sue SWW, W, Waassecaeca, MN 56093 U, MN 56093 USSA 800.247.8256 +1 507 833 8822 cA 800.247.8256 +1 507 833 8822 cincinchchconneconnectitivitvityy.c.com om SMA Reverse Polarity - 50 Ohm Specifications INCHES (MILLIMETERS) CUSTOMER DRAWINGS AVAILABLE UPON REQUEST ELECTRICAL RATINGS RF High Potential Withstanding Voltage: (Vrms minimum, tested at 4 Impedance: 50 ohms and 7 MHz) Frequency Range: Connectors for RG-316 LMR-100, 195, 200 ................................... 500 Flexible cable connectors ..................................................... 0-12.4 GHz Connectors for RG-58, RG-142, LMR-240, uncabled receptacles ... 670 Uncabled receptacles ........................................................... 0-18.0 GHz MECHANICAL RATINGS VSWR: (f = GHz) Straight Right Angle Engagement Design: MIL-C-39012, Series SMA Cabled Connectors Cabled Connectors Engagement/Disengagement Force: 2 inch-pounds maximum RG-316, LMR-100 cable ........... 1.15 + .02f 1.15 + .03f Mating Torque: 7 to 10 inch-pounds RG-58, LMR-195 cable ............ 1.17 + .025f 1.17 + .06f Bulkhead Mounting Nut Torque: 15 inch-pounds RG-142 cable ............................ 1.17 + .02f 1.15 + .03f Coupling Proof Torque: 15 inch-pounds minimum LMR-200, LMR-240 cable ............. 1.10 + .03f 1.10 + .06f Coupling Nut Retention: 60 pounds minimum Uncabled receptacles .......................................................................... N/A Contact Retention: Working Voltage: (Vrms maximum) 6 lbs. minimum axial force (captivated contacts) Connectors for Cable Type Sea Level 70K Feet 4 inch-ounce minimum torque (uncabled receptacles) RG-316 LMR-100, 195, 200 ................................... 250 65 Cable Retention: Axial Force* Torque RG-58, RG-142, LMR-240, uncabled receptacles .. 335 85 (pounds) (in-oz) Dielectric Withstanding Voltage: (VRMS minimum at sea level) Connectors for RG-316, LMR-100 ............ 20 N/A Connectors for RG-316 LMR-100, 195, 200 ...................................... 750 Connectors for LMR195, 200 .................... 30 N/A Connectors for RG-58, RG-142, LMR-240, uncabled receptacles . 1000 Connectors for RG-58, LMR-240 .............. 40 N/A = Corona Level: (Volts minimum at 70,000 feet) Connectors for RG-142 ............................. 45 N/A Connectors for RG-316, LMR-100, 195, 200 ................................... 190 *Or cable breaking strength whichever is less. Connectors for RG-58, RG-142, LMR-240, uncabled receptacles ... 250 Durability: 500 cycles minimum Insertion Loss: (dB maximum) ENVIRONMENTAL RATINGS (Meets or exceed the applicable paragraph Straight flexible cable of MIL-C-39012) connectors ...............................06 f (GHz), tested at 6 GHz Temperature Range: - 65C to + 165C Right angle flexible cable Thermal Shock: MIL-STD-202, Method 107, Condition B connectors ................................ 0.15 f (GHz), tested at 6 GHz Corrosion: MIL-STD-202, Method 101, Condition B Low loss flexible straight Shock: MIL-STD-202, Method 213, Condition I cable connectors ............................. 0.06 f (GHz), tested at 1 GHz Vibration: MIL-STD-202, Method 204, Condition D Low loss flexible right angle Moisture Resistance: MIL-STD-202, Method 106 cable connectors ....................... 0.15 f (GHz), tested at 1 GHz MATERIAL SPECIFICATIONS Uncabled receptacles, field replaceable ............................................ N/A Bodies: Brass per QQ-B-626, gold plated* per MIL-G-45204 .00001 min. Insulation Resistance: 5000 megohms minimum or nickel plated per QQ-N-290 Contact Resistance: (milliohms maximum) After Contacts: Male - brass per QQ-B-626, gold plated per MIL-G-45204 Initial Environmental .00003 min. Center contact (straight cabled connectors Female - beryllium copper per QQ-C-530, gold plated per MIL- and uncabled receptacles) ............................ 3.0* 4.0* G-45204 .00003 min. Center contact (right angle cabled Nut Retention Spring: Beryllium copper per QQ-C-533. Unplated connectors ......................................................4.0 6.0 Insulators: PTFE fluorocarbon per ASTM D 1710 and ASTM D 1457 or Outer contact (all connectors) ............................2.0 N/A Tefzel per ASTM D 3159 Braid to body (gold plated connectors) ..............0.5 N/A Expansion Caps: Brass per QQ-B-613, gold plated per MIL-G-45204 Braid to body (nickel plated connectors) ............5.0 N/A .00001 min. or nickel plated per QQ-N-290 RF Leakage: (dB minimum, tested at 2.5 GHz) Crimp Sleeves: Copper per WW-T-799 or brass per QQ-B-613, gold Flexible cable connectors ............................................................. -60 dB plated per MIL-G-45204 .00001 min. or nickel plated per QQ-N-290 Uncabled receptacles and adapters ................................................. N/A Mounting Hardware: Brass per QQ-B-626 or QQ-B-613, gold plated per MIL-G-45204 .00001 min. or nickel plated per QQ-N-290 MATING ENGAGEMENT FOR SMA REVERSE POLARITY SERIES PER FCC RULE 15 NON-STANDARD INTERFACE PLUG NOTES JACK 1. ID OF CONTACT TO MEET VSWR, CONTACT RESISTANCE AND INSERTION WITHDRAWAL FORCES WHEN MATED WITH DIA .0355- .0370 MALE PIN. PLUG JACK Avoid user injury due to misapplication. See safety advisory definitions inside front cover. CCinincch Ch Coonnnnecectitivitvity Soy Solulutitioonsns 299 J299 Johnsohnson Aon Avveennue Sue SWW, W, Waassecaeca, MN 56093 U, MN 56093 USSA 800.247.8256 +1 507 833 8822 cA 800.247.8256 +1 507 833 8822 cincinchchconneconnectitivitvityy.c.com om