APPLICATION TOOLING ID tools and machines ID tools and machines 5-B The arrow mark indocates the press that is applicable to the applicator. ID applicator ID applicator ID applicator ID applicator for discrete wires and jumper wires for 1.27mm(.050 ) pitch ribbon cables for discrete wires and jumper wires for 1.27mm(.050 ) pitch ribbon cables H2 series HID series H2A series FP series Auto. ID machines for discrete wires BCD-M5BP Auto. ID machines for shielded wires Hand press Pneumatic press Pneumatic press Pneumatic press SCD-M15B HPD-M2A HPD-M2A-HID AP-2 AP-2D AP-2H ID applicator Pneumatic press for 1.27mm(.050 ) ribbon cable connectors. Operation is for discrete wires easy and safe as the connector and cable can be MKD-LP Versatile press applicable set while the sliding Versatile press applicable to to various ID applicators. applicator is drawn out of various ID applicators. the terminating section. Specifications Specifications Dimensions: (W x L x H) Specifications Specifications Dimensions: (W x L x H)141 x 252 x 301mm Dimensions: (W x L x H)141 x 252 x 301mm Dimensions: (W x L x H)130 x 280 x 383mm 184 x 302 x 491mm (5.6 x 9.9 x 11.9 ) (7.2 x 11.9 x 19.3 ) (5.6 x 9.9 x 11.9 ) (5.1 x 11.0 x 15.1 ) Weight: Approx. 16kg(35lb) Weight: Approx. 16kg(35lb) Weight: Approx. 7kg(15 lb) Weight: Approx. 30kg(66 lb) Air pressure: 490 to 690 kPa (5 to 7 kgf/sq.cm) Air pressure : 490 to 690 kPa (5 to 7 kgf/sq.cm) Air pressure: 490 to 686 kPa (5 to 7 kgf/sq.cm) Note: The difference between the HPD-M2A and Strokes: 50 max./minute Strokes: 50 max./minute Strokes: 50 max./minute the HPD-M2A-HID is the main shaft. Pressure output: Approx. 3.8kN (390 kgf) Applicable connectors: JST s RA, RC & RX connectors Pressure output: Approx. 7.5kN (Approx. 760 kgf)when Auto. ID machines for 2.5 mm (.098 ) HPD-M2A is for the H2A series applicators when air pressure is 490 kPa (5 kgf/sq.cm) Pressure output: Approx. 3.8kN (Approx. 390 kgf) air pressure is 490 kPa (5 kgf/sq.cm) HPD-M2A-HID is for the HID series Operation method: Air-operated foot valve when air pressure is 490 kPa (5 kgf/sq.cm) & 2.0 mm (.079 ) pitch jumper wires Operation method: Air-operated foot valve applicators Dies: Applicator replacement Dies: Applicator replacement Operation method: Air-operated foot valve Note: For the HR connectors, please use AP-2H Dies: Applicator replacement RCD-M9BE press that provides bigger pressure output. Pistol tool Optional: Control unit for pneumatic presses Pneumatic press Pneumatic press for discrete wires and jumper wires MP-CU IDB-12 MKD-LP+AP-K2N MP-2A <Made in The filter regulator & pressure switch help to make reliable operation even Germany> under the air condition is not stable. Light and compact. Specifications Auto. ID machines for multi-harnesses Dimensions: (W x L x H)200 x 300 x 230mm(7.9 x 11.8 x 9.1 ) Weight: Approx. 5kg(11 lb) Specifications Power source: 100/115/220/240V AC, single-phase, 50/60 Hz CAM-M12B Dimensions: (W x L x H)23 x 135 x 175mm Air pressure: 490 to 686 kPa (5 to 7 kgf/sq.cm) (.9 x 5.3 x 6.9 ) Accessories: Foot switch, power cord Weight: 270g(1lb) Dies: Head adaptor (IDH series) Note: MKD-LP applicators are not applicable replacement to the connectors with glass-filled nylon Compact, light and maintenance free. No housings i.e. 12 to 15-circuit DD/DS inspection or lubrication is necessary. Simple and compact pneumatic press without connectors and 13 to 16-circuit KR electrically controlled unit. connectors. Specifications Specifications Dimensions: (WXLXH)180X150X250mm Dimensions: (WXLXH)95X515X203mm (7.1 X5.9 X9.8 ) (3.7 X20.3 X8.0 ) Weight: Approx. 10kg(22lb) Weight: Approx. 6.5kg(14lb) Air pressure: 490 to 690kPa (5 to 7kgf/sq.cm) Applicable press: AP-K2N Dies: Dies-Main body integrated Applicable connectors: JST S connectors 948 Strokes: 50 max./minute 949 for discrete wires.ID TOOLS ID TOOLS 5-B Hand press: HPD-M2A Pneumatic press: AP-2H Pneumatic press: AP-2H Hand press: HPD-M2A Hand press: HPD-M2A-HID Pneumatic press: AP-2D Pistol tool: IDB-12 Pneumatic press: AP-2 or AP-2H Electric press: AP-K2N Electric press: AP-K2N Applicator Applicator Head adaptor Applicator Applicator Applicator Pitch-feeding applicator H2A series H2 series HID series MKD-LP with die set MKD-LR with die set FP series IDH series Connector Connector Pitch mm(in.) Series Series Pitch mm(in.) 0.8(.031) 0.8(.031) SUR H2A-SUR H2-SUR30ED-X SUR SR H2A-SR H2-SR20ED-X SR 1.0(.039) SSR H2A-SSR H2-SSR20ED-X SSR 1.0(.039) ASR H2A-ASR H2-ASR20ED-X ASR CZ H2A-CZ H2-CZ20ED-X CZ 1.5(.059) 1.5(.059) ZR H2A-ZR H2-ZR20ED-X MKD-LP + MKD-DS-ZR IDH-ZR12 ZR ZA H2A-ZA H2-ZA20ED-X MKD-LP + MKD-DS-ZA ZA KR (Note 3) H2A-KR/XR H2-KR/XR20ED-X MKD-LP + MKD-DS-KR (Note 1) MKD - LR + MKD-LR-DS-KR IDH-KR12 KR(Note3) KRD H2A-KRD H2-KRD20DD-Y KRD CK (Note 4) H2A-KR/XR H2-KR/XR20ED-X CK(Note4) 2.0(.079) CR H2A-CR H2-CR20ED-X CR 2.0(.079) DR H2A-DR H2-DR20ED-X MKD-LP + MKD-DS-DR IDH-DR12 DR DA H2A-DA H2-DA20ED-X MKD-LP + MKD-DS-DA MKD - LR + MKD-LR-DS-DA IDH-DA12 DA DD MKD-LP + MKD-DS-DD/DS DD H2A-DD/DS H2-DD/DS20ED-X IDH-DD/DS12 (Note 1) DS DS NR H2A-NR H2-NR20ED-X IDH-NR12 MKD-LP + MKD-DS-NR NR NRD H2A-NRD H2-NRD20DD-Y MKD-LP + MKD-DS-NRD (Note 2) NRD HR H2A-HR H2-HR20ED-X MKD-LP + MKD-DS-HR MKD - LR + MKD-LR-DS-HR IDH-HR12 HR 2.5(.098) 2.5(.098) DB H2A-DB H2-DB20ED-X MKD-LP + MKD-DS-DB/DC MKD - LR + MKD-LR-DS-DB IDH-DB/DC12 DB DG H2A-DG MKD-LP + MKD-DS-DG DG BR H2A-BR H2-BR20ED-X MKD-LP + MKD-DS-BR BR RA HID-RA/RX FCD-DS FP2-RA/RX RA 2.54(.100) RC HID-RC FCD-DS FP2-RC RC 2.54(.100) RX HID-RA/RX FCD-DS FP2-RA/RX RX 3.96(.156) VR H2A-VR H2-VR15DD-Y MKD-LP + MKD-DS-VR (Note 2) IDH-VR12 VR 3.96(.156) Ribbon cable cutter HID-FC Ribbon cable cutter Note 1: MKD-LP applicators are not applicable to the connectors with glass- filled nylon housings i.e. 12 to 15-circuit DD/DS connectors and 13 to 16-circuit KR connectors. Note 2: End-connection only (not through processing) Note 3: ID tools for the standard KR series connectors are not applicable to the ( )KR-4K-** connectors. For ( )KR-4K-**, use the tools for the CR series connectors. Note 4: ID tools for the standard CK series connectors are not applicable to the ( )CK-6H-** connectors. For ( )CK-6H-**, use the tools for the KR/XR series connectors. 950 951