Y5V Dielectric General Specifications GENERAL DESCRIPTION Y5V formulations are for general-purpose use in a limited temperature range. They have a wide temperature characteristic of +22% 82% capacitance change over the operating temperature range of 30C to +85C. These characteristics make Y5V ideal for decoupling applications within limited temperature range. PART NUMBER (SEE PAGE 4 FOR COMPLETE PART NUMBER EXPLANATION) 0805 3 G 104 Z A T 2 A Size Voltage Dielectric Capacitance Capacitance Failure Terminations Packaging Special (L x W) 6.3V = 6 Y5V = G Code (In pF) Tolerance Rate T = Plated Ni 2 = 7 Reel Code 10V = Z 2 Sig. Digits + Z = +80 20% A = Not and Sn 4 = 13 Reel A = Std. 16V = Y Number of Applicable Product 25V = 3 Zeros 50V = 5 Capacitance Change Temperature Coefficient Insulation Resistance vs. Temperature vs. DC Bias Voltage 10,000 +20 +10 +40 0 +20 -10 1,000 -20 0 -30 -20 -40 -40 -50 100 -60 -60 -70 -80 -80 0 -100 -55 -35 -15 +5 +25 +45 +65 +85 +105 +125 +20 +30 +40 +50 +60 +70 +80 +90 0 20 40 60 80 100 Temperature C Temperature C % DC Bias Voltage 0.1 F - 0603 0.22 F - 0805 1 F - 1206 Impedance vs. Frequency Impedance vs. Frequency Impedance vs. Frequency 1,000 1,000 10,000 1,000 100 100 100 10 10 10 1 1 1 0.1 0.1 0.1 0.01 0.01 0.01 10,000 100,000 1,000,000 10,000,000 10,000 100,000 1,000,000 10,000,000 10,000 100,000 1,000,000 10,000,000 Frequency (Hz) Frequency (Hz) Frequency (Hz) The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available online at www.avx.com/disclaimer/ by reference and should be reviewed in full before placing any order. 29 101316 % Capacitance Z (Ohms) Z (Ohms) c/c (%) Insulation Resistance (Ohm-Farads) Z (Ohms)Y5V Dielectric Specifications and Test Methods Parameter/Test Y5V Specification Limits Measuring Conditions Operating Temperature Range -30C to +85C Temperature Cycle Chamber Capacitance Within specified tolerance Freq.: 1.0 kHz 10% 5.0% for 50V DC rating Voltage: 1.0Vrms .2V 7.0% for 25V DC rating Dissipation Factor For Cap > 10 F, 0.5Vrms 120Hz 9.0% for 16V DC rating 12.5% for 10V DC rating 10,000M or 500M - F, Charge device with rated voltage for 120 5 secs Insulation Resistance whichever is less room temp/humidity Charge device with 250% of rated voltage for Dielectric Strength No breakdown or visual defects 1-5 seconds, w/charge and discharge current limited to 50 mA (max) Appearance No defects Deflection: 2mm Capacitance Test Time: 30 seconds 30% Variation Resistance to Flexure Dissipation Meets Initial Values (As Above) Stresses Factor Insulation Initial Value x 0.1 Resistance 95% of each terminal should be covered with Dip device in eutectic solder at 230 5C Solderability fresh solder for 5.0 0.5 seconds Appearance No defects, <25% leaching of either end terminal Capacitance 20% Variation Dip device in eutectic solder at 260C for 60 Dissipation Resistance to Meets Initial Values (As Above) seconds. Store at room temperature for 24 2 Factor Solder Heat hours before measuring electrical properties. Insulation Meets Initial Values (As Above) Resistance Dielectric Meets Initial Values (As Above) Strength Appearance No visual defects Step 1: -30C 2 30 3 minutes Capacitance 20% Step 2: Room Temp 3 minutes Variation Dissipation Meets Initial Values (As Above) Step 3: +85C 2 30 3 minutes Thermal Shock Factor Insulation Meets Initial Values (As Above) Step 4: Room Temp 3 minutes Resistance Dielectric Repeat for 5 cycles and measure after Meets Initial Values (As Above) Strength 24 2 hours at room temperature Appearance No visual defects Capacitance 30% Charge device with twice rated voltage in test Variation chamber set at 85C 2C Dissipation for 1000 hours (+48, -0) Initial Value x 1.5 (See Above) Load Life Factor Insulation Remove from test chamber and stabilize at room Initial Value x 0.1 (See Above) Resistance temperature for 24 2 hours before measuring. Dielectric Meets Initial Values (As Above) Strength Appearance No visual defects Capacitance 30% Store in a test chamber set at 85C 2C/ 85% Variation 5% relative humidity for 1000 hours Dissipation (+48, -0) with rated voltage applied. Initial Value x 1.5 (See above) Load Factor Humidity Remove from chamber and stabilize at room Insulation Initial Value x 0.1 (See Above) temperature and humidity for Resistance 24 2 hours before measuring. Dielectric Meets Initial Values (As Above) Strength The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available online at www.avx.com/disclaimer/ by reference and should be reviewed in full before placing any order. 30 101316