AC-DC Power Supplies ALM200 Series 200 Watts Medical & IT Safety Approvals Energy Efficiency Level VI & EU CoC Tier 2 Compliant 4th Edition Medical EMC IP32 Environmental Rating Class I and Class II Versions <0.15 W Standby Power 0 C to 60 C Operation Low Earth Leakage Current 3 Year Warranty Dimensions: The ALM200 series of medical external power supplies is fully approved to international medical & ALM200: 8.23 x 3.23 x 1.69 (209.0 x 82.0 x 43.0 mm) IT safety standards. It has been designed with very high efficiency and low standby power, enabling it to meet the latest environmental legislation. The unit has a fully sealed enclosure complying with IP32 and a smooth surface finish making it easier to wipe down in a clinical setting. Models & Ratings (4) (1,2,3) Output Power Output Voltage Output Current Load Regulation Efficiency Model Number 12.0 V 16.7 A 91.7% ALM200PS12 3.5% 15.0 V 13.4 A 92.4% ALM200PS15 200 W 19.0 V 10.6 A 92.8% ALM200PS19 24.0 V 8.4 A 3.0% 92.2% ALM200PS24 48.0 V 4.2 A 92.4% ALM200PS48 Notes 1. For class II versions, add suffix C2-8 to the end of the part number e.g. 3. Power de-rated <100 VAC for 12 & 15 V models, refer to input specifications. ALM200PS24C2-8. 4. Typical average value measured at 25%, 50%, 75% and 100% load at 230VAC 2. For optional input connector retention clip add suffix -A to the model number, e.g. ALM200PS24-A (not available for C2 versions) Mechanical Details 8.2 (209.0) 35.4, 0.78 (900.0 20.0) Class I 0.193 (4.9) AC Input 1.96, 0.78 (50.0 20.0) IEC 320-C14 0.78, 0.079 (20.0 2.0) 3.2 (82.0) 1.41, 0.079 (36.0 2.0) Optional Class II AC Input IEC 320-C8 1.69 (43.0) 0.063 (1.6) 7.48 (190.0) 5.12 (130.2) Molex 39-03-9042 2.5 (63.5) Pin Connection 1 RTN 1.97 (50.2) 2 RTN 3 +Vout 4 +Vout Notes 1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except 5. For US mains lead order part US-MAINS-IEC for C14 versions, or US-MAINS-8 output cable length. for C8 versions. 2. Weight: 2.01 lbs (910 kg) approx. 6. Output connector: 4 pin molex Mini-Fit part number 39-03-9042 housing with 3. For European mains lead order part EU-MAINS-IEC for C14 versions, or EU- 45750 crimp terminals and mates with molex header 46999-0516 or equivalent. MAINS-8 for C8 versions. 4. For UK mains lead order part UK-MAINS-IEC for C14 versions, or UK-MAINS-8 for C8 versions. www.xppower.com 1AC-DC Power Supplies ALM200 Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions 19, 24 & 48V models: Derate linearly from 100% load at 90 VAC to 80% load at 80 VAC. 300 VAC/5 s maximum. Input Voltage 80 264 VAC 12 & 15 V models: Derate linearly from 100% load at 100 VAC to 95% load at 90 VAC and then derate linearly 80% load at 80 VAC, 300 VAC/5 s maximum. Input Frequency 47 63 Hz Input Current 2.0/1.0 A Measured at 115/230 VAC Inrush Current 160 A 230 VAC, cold start at 25 C Power Factor >0.9 EN61000-3-2 Class A Earth Leakage Current 250 A 264 VAC, 60 Hz No Load Input Power 0.15 W Input Protection T5A/250 VAC internal fuse in both line & neutral Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 12 48 VDC See Models and Ratings table Initial Set Accuracy 2 % At 50% load Minimum Load No minimum load required Start Up Delay 1 1.5 s Start Up Rise Time 40 ms Hold Up Time 20 30 ms Full load and 115/230 VAC Line Regulation 0.5 % Load Regulation % See Models and Ratings table Maximum deviation, recovering to less than 1% within Transient Response 4% 500 s for 50-75-50% load change 20 MHz bandwidth, measured with 20 MHz Bandwidth and Ripple and Noise 1.5 % pk-pk 10 F electrolytic in parallel with 0.1 F ceramic capacitor. Overshoot 5 10 % At turn on / turn off Overload Protection 115 175 % Overvoltage Protection 150 % Recycle mains to reset Short Circuit Protection Trip and restart (hiccup), auto resetting Thermal Protection Measured internally, auto resetting Temperature Coefficient 0.02 %/C Patient Leakage Current 95 A 264 VAC, 60 Hz Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Temperature 0 +60 C Derate from 100% load at 40 C to 35% load at 60 C Cooling Natural convection Operating Humidity 5 95 %RH Non-condensing Storage Temperature -25 +80 C Operating Altitude 5000 m Shock IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes Vibration IEC68-2-6, 10-500 Hz, 2 g 10 mins/sweep, 60 mins for each of 3 axes Derating Curve 100% 80% 60% 40% 20% 0 20 40 60 Ambient Temperature (C) www.xppower.com 2 Output Power (%)