U.I. Lapp DATA SHEET GmbH DB1136752 LFLEX 115 CY valid from: 19.08.2014 Application LFLEX 115 CY cables are control cables for occasional flexible use and fixed installation under normal mechanical load conditions. They are among others designed for use in dry, damp or wet rooms. Outdoor use: They may only be installed with UV protection and considering the temperature range. At room temperature they are widely resistant to acids, caustic solu- tions and certain oils. They are suitable for free, non-continuously recurring movement without tensile load. Continuous operational movements, restricted guidance, usage of these cables in moving cable carriers or on motor drum guidance or under a strain of more than 15 N/mm conductor cross-section are not allowed. The screen is a protection against electrical interference. Application range: Control units for machine tools, conveyor systems, measurement and control technology, systems for data processing. Design Design Based on EN 50525-2-51 ressp. VDE 0285-525-2-51 Conductor Fine wire strands of bare copper acc. to IEC 60228 resp. VDE 0295, Class 5 Core insulation PVC compound TI2 acc. to DIN EN 50363-3 resp. VDE 0207-363-3 with increased requirements acc. to Lapp specification Core identification code according to VDE 0293-1, with or without GN/YE ground conductor, black cores with white numbers acc. to DIN EN 50334 resp. VDE 0293-334 Wrapping Plastic foil Screen Braid of tinned copper, coverage = 85% (nominal value) Outer sheath PVC compound TM2 acc. to DIN EN 50363-4-1 resp. VDE 0207-363-4-1 Colour: Siver grey, similar RAL 7001 Electrical properties at 20C Nominal voltage 300 / 500 V Test voltage Core/core 4000 V AC Core/screen 2000 V AC Transfer impedance max. 250 m/m at 30 MHz Mechanical and thermal properties Minimum bending radius Occasional flexing: 20 x outer diameter Fixed installation: 6 x outer diameter Temperature range Occasional flexing: - 5C up to +70C max. conductor temp. Fixed installation: - 40C up to +80C max. conductor temp. Flammability acc. to IEC 60332-1-2 resp. VDE 0482-332-1-2 Tests acc. to IEC 60811, EN 50395, EN 50396 EC-Directives This cable is conform to the EC-Directives 2006/95/EC (Low Voltage Directive) and 2011/65/EG (RoHS, Restriction of the use of certain hazardous substances). Originator: ROKR / PDC Document: DB1136752DE page 1 of 1 approved: HAPF / PDC All rights reserved acc. to DIN ISO 16016. PD 0019/2.2 11.10EN X-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for lapp kabel manufacturer: Other Similar products are found below : 00008779 0026122 0026123 0026156 0026103 0026124 0026127 0026253 61791330 70002708 EPIC KIT H-A 10 BS SGR-LB M20 EPIC KIT H-A 10 BS TBF-LB M20 EPIC KIT H-A 10 SS TG M20 EPIC KIT H-A 16 SS TG M20 EPIC KIT H-A 3 BS AGS EPIC KIT H-A 4 BS MTGVB M20 EPIC KIT H-BE 16 BS AG EPIC KIT H-BE 6 BS SGR-LB M20 EPIC KIT H-BE 6 BS TBF-LB M20 EPIC KIT H-BE 6 SS TG M20 EPIC KIT H-BE 6 SS TS M20 EPIC KIT LS1 A1 3+PE+4 K 22260044 22260046 22260134 22260993 22262020 22262022 22262023 22262027 21700623 22260045 22260122 22260638 22260651 22262011 4510052 4510073 4520002 4520003 4520013 4520021 52005949 52005990 52006010 52006030 52006173 52006630 52006650 52115750