F (daN) Colson cable ties Performance UV protected according to norm IEC 62275 type 1 UV protected black cable ties for outdoor use Conform to EN 62275 type 1 (NFC 68-146) These black cable ties have successfully undergone UV resistancecable ties for electrical installation and climatic ageing tests representing actual conditions of use Test conditions : These cycles combine a 1000 hours radiance under arc or xenon lamp Temperature : 23 C according to ISO 4892-2 method 1 Relative humidity of air : 50 % . Traction speed : 25 4 mm/min Resistance to external agents Resistance to rain Technical data Constant high quality Type tests Raw material test Product test on the production line and in the laboratory Packaging test Tensile strength (according to EN 50146) Humidity absorption: 07% Good resistance to oils, greases, petroleum products, % saline mist and diluted acids 400 Resistance to low temperatures Resistance to sun Tensile strength depending on temperature 350 300 250 200 180 100 % of strength at 23 C 140 120 according to EN 50146 100 80 Temperature 60 (C) 50 Assembly 30C Maximum temperatures : - 40 - 20 0 20 40 60 80 100 Fitted 40C 85C continuous 100C 1000 hrs UV resistant Quality of tensile strength Colson approvals Diagram (A)- Diagram (B) - Tensile strength Oxygen index : EN ISO 4589-1 and ASTM D 2863-00, 20 % Max. ratchet Cat. Nos. force Test dia. (mm) Min. strength Corrosiveness of fumes : NFC 20-453, < 5 % (daN) According to EN 50146 (daN) Flame retardancy : UL 94 HB 0319 13 4 20 36 Type Colson black 0319 16 5 26 53 UV protection yes 0319 19 5 26 53 Polyamide material 12 0319 20 55 74 53 Teeth external 0319 21 55 74 53 (1) Halogen free yes 0319 22 4 20 22 (2) Humidity absorbtion <07 % 0319 25 4 20 22 Operating temperature - 20,000 hrs 85 C (A) (B) - 1,000 hrs 100 C Resistance to low temperatures - fitted 40 C - assembly 30 C Flame retardancy UL 94 HB Oxygen index (LOI) 20 % (EN ISO 4589-1/ASTM D 2863-00) (3) Self-extinguishing 650 C Fire resistance (1) Conform to Class I ASTM D 4066 Flame retardant (2) Conform to ISO 62 (EH 0-23C Conform to UL 94 requirements, HB classi cation (3) Conform to IEC 60695-2-11 Glow-wire ammability resistance according to IEC 60695-2-11 : 650 C Oxygen index (LOI) according to Colson traceability EN ISO 4589-1/ASTM D 2863-00 : 20 % Low re hazard polyamide Each Colson cable tie can be identified, underlining Legrands commitment to the consumer, so that you can always be sure you are using a genuine Colson Dimensions Accessories for Colson Cat. No. 0319 50 Cat. No. 0319 55 15 37 65 5 12 435 95 92 18 14 159 154 161 IND 2012 v1.indd 159154 161 IND 2012 v1.indd 159 02/05/2012 10:5502/05/2012 10:55 10 215 10 185X-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for legrand manufacturer: Other Similar products are found below : MPX3 32H 11-17A MPX3 32H 22-32A MPX3 32H 4-6A MPX3 32H 6-10A MPX3 63H 11-17A MPX3 63H 28-40A S 303 B40 TX T1+T2 8/50 4P RC302 RC312 M 250 4 CTX3 3P 32A 2NO2NC 230V AC WZ 301 DM 340 LP 452 MPX3 32H 0.1-0.16A MPX3 32H 0.16- 0.25A MPX3 32H 0.25-0.4A MPX3 32H 1.6-2.5A MPX3 32H 18-26A MPX3 32H 2.5-4.0A MPX3 32H 5-8A MPX3 32H 9-13A MPX3 63H 34-50A MPX3 63H 6-10A SM 363 230V 4NO PB 441 WS 312 S 301 B13 TX S 301 C63 TX FR 301 32 S 301N C40 DX S 312 C32 DX PTTR20HACUSBGRY RDSZNI RDZWH WSPCBKTBK 003840 CTX3 MINI 3P 16A 1NC 230VAC FR 303 40 FR 304 63 PB 411 S 303 B63 TX M 250 10 CTX3 3P 22A 1NO1NC 24V DC CTX3 3P 9A 1NO1NC 230V AC CTX3 MINI 3P 12A 1NC 230VAC CTX3 MINI 3P 6A 1NC 230VAC 416858 MPX3 32H 1.0-1.6A