Voltage transducer DVL 125 V = 125 V PN For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Applications Bipolar and insulated measurement up to 188 V Single or three phase inverters Current output Propulsion and braking choppers Input and output connections with M5 studs Propulsion converters Compatible with AV 100 family. Auxiliary converters High power drives Advantages Substations. Low consumption and low losses Standards Compact design Good behavior under common mode variations EN 50155: 2007 Excellent accuracy (offset, sensitivity, linearity) EN 50178: 1997 Good response time EN 50124-1: 2001 Low temperature drift EN 50121-3-2: 2006 High immunity to external interferences. UL 508: 2013 IEC 61010-1: 2010. Application Domains Traction (fixed and onboard) Industrial. N 97.H9.36.000.0 Page 1/9 10June2016/version 1 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.comDVL 125 Absolute maximum ratings Parameter Symbol Unit Value Maximum supply voltage (V = 0 V, 0.1 s) U V 34 P C Maximum supply voltage (working) (40 85 C) U V 26.4 C Maximum input voltage (40 85 C) V V 188 P 125 Maximum steady state input voltage (40 85 C) V V PN see derating on figure 2 Absolute maximum ratings apply at 25 C unless otherwise noted. Stresses above these ratings may cause permanent damage. Exposure to absolute maximum ratings for extended periods may degrade reliability. UL 508: Ratings and assumptions of certification File E189713 Volume: 2 Section: 7 Standards USR indicated investigation to the Standard for Industrial Control Equipment UL 508. CNR Indicated investigation to the Canadian standard for Industrial Control Equipment CSA C22.2 No. 14-13 Conditions of acceptability When installed in the end-use equipment, consideration shall be given to the following: 1 - These devices must be mounted in a suitable end-use enclosure. 2 - The terminal have not been evaluated for field wiring. 3 - Low voltage circuits are intended to be powered by a circuit derived from an isolating source (such as transformer, optical isolator, limiting impedanc e or electro-mechanical relay) and having no direct connection back to the primary circuit (other than through the grounding means). Marking Only those products bearing the UL or UR Mark should be considered to be Listed or Recognized and covered under ULs Follow- Up Service. Always look for the Mark on the product. Page 2/9 10June2016/version 1 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com