Current Transducer HAL 50..600-S For the electronic measurement of currents: DC, AC, pulsed..., I = 50 .. 600 A with galvanic isolation between the primary circuit (high power) and PN the secondary circuit (electronic circuit). Electrical data Primary nominal Primary current Type RoHS since 4) current rms measuring range date code I (A) I (A) PN PM 50 150 HAL 50-S 46180 100 300 HAL 100-S 46065 200 600 HAL 200-S 46090 Features 300 900 HAL 300-S 46142 Hall effect measuring principle 400 1000 HAL 400-S 46114 Galvanic isolation between primary 500 1000 HAL 500-S 46306 600 1000 HAL 600-S 46059 and secondary circuit Isolation voltage 3000V I Overload Capability (Ampere Turns) 30,000 A P Low power consumption V Output voltage (Analog) I 4 V OUT PN Extended measuring range(3 x I ) PN R Load resistance T = 0 .. + 70C > 1 k L A Isolated plastic case recognized T = - 25 .. + 85C > 3 k A according to UL 94-V0 V Supply voltage ( 5 %) 15 V C Advantages I Current consumption < 25 mA C 1) Easy installation V Rated isolation voltage rms 500 V b Small size and space saving V Rms voltage for AC isolation test, 50 Hz, 1 min 3 kV d Only one design for wide current R Isolation resistance 500 V > 500 M is DC ratings range Accuracy - Dynamic performance data High immunity to external interference X Accuracy I , T = 25C, 15 V < 1 % PN A 2) e Linearity error < 0.5 % of I L PN Applications V Eletrical offset voltage T = 25C HAL 50-S < 20 mV OE A HAL 100..600-S < 10 mV AC variable speed drives V Magnetic offset voltage I = 0, OM P DC motor drives after an overload of 3 x I HAL 50-S < 30 mV PN HAL 100..200-S < 20 mV Battery supplied applications HAL 300..600-S < 10 mV Uninterruptable Power Supplies TCV Temperature coefficient of V HAL 50-S < 2.0 mV/K OE OE (UPS) HAL 100..600-S < 1.0 mV/K Switched Mode Power Supplies TCV Temperature coefficient of V ( % of reading ) 0.05 %/K OUT OUT t Response time to 90% of I step 3 s (SMPS) r PN 3) BW Frequency bandwidth (- 3 dB) DC .. 50 kHz Power supplies for welding applications. General data Application domain T Ambient operating temperature - 25 .. + 85 C A T Ambient storage temperature - 25 .. + 85 C S Industrial m Mass app. 75 g 4) Standard Safety EN 50178 : 1994 EMC EN50082-2: 1992 EN50081-1: 1992 Deviation in output when tested to EN 61000-4-6 < 20 % of I PN Deviation in output when tested to EN 61000-4-3 < 20 % of I PN 1) Notes : Overvoltage Category III, Pollution Degree 2 2) Excludes the electrical offset 3) Derating is needed to avoid excessive core heating at high frequency. 4) Please consult characterisation report for more technical details and Page 1/2 application advice. www.lem.com 110209/5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.Dimensions HAL 50..600-S (in mm. 1 mm = 0.0394 inch) Secondary terminals Terminal 1 : supply voltage +15V Terminal 2 : supply voltage -15V Terminal 3 : output Terminal 4 : 0V Mechanical characteristics Safety General tolerance 0.5 mm Primary through-hole 20 mm x 15 mm Connection of secondary Molex 5045-04-A This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturers operating instructions. Remarks V is positive when I flows in the direction of the arrow. OUT P Temperature of the primary conductor should not exceed Caution, risk of electrical shock 90C. This is a standard model. For different versions please When operating the transducer, certain parts of the module contact us. can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/2 www.lem.com 110209/5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.