Current Transducer HLSR-P/SP3 series I = 10 ... 50 A PN Ref: HLSR 10-P/SP3, HLSR 20-P/SP3, HLSR 40-P/SP3, HLSR 50-P/SP3 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Applications Features Open loop multi-range current transducer AC variable speed and servo motor drives Static converters for DC motor drives Voltage output Single supply +5 V Battery supplied applications Galvanic separation between primary and secondary Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Low power consumption Compact design for THT PCB mounting Power supplies for welding applications Factory calibrated Combiner box High bandwidth, very low loss magnetic core. MPPT. Special feature Standards EN 50178: 1997 V nominal 0.625 V. out IEC 61010-1: 2010 Advantages IEC 61326-1: 2012 Extremely low profile: h = 12 mm UL 508: 2010. Low foot-print Application Domain Low offset drift Over-drivable V . Industrial. ref N97.J3.13.003.0, N97.J3.17.003.0, N97.J3.23.003.0, N97.J3.25.003.0 Page 1/11 17September2015/Version 1 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.comHLSR-P/SP3 series Absolute maximum ratings Parameter Symbol Unit Value Supply voltage (not destructive) U V 8 C Supply voltage (not entering non standard modes) U V 6.5 C Primary conductor temperature T C 120 B ESD rating, Human Body Model (HBM) U kV 2 ESD Stresses above these ratings may cause permanent damage. Exposure to absolute maximum ratings for extended periods may degrade reliability. UL 508: Ratings and assumptions of certification File E189713 Volume: 2 Section: 5 Standards CSA C22.2 NO. 14-10 INDUSTRIAL CONTROL EQUIPMENT - Edition 11 - Revision Date 2011/08/01 UL 508 STANDARD FOR INDUSTRIAL CONTROL EQUIPMENT - Edition 17 - Revision Date 2010/04/15 Ratings Parameter Symbol Unit Value Primary involved potential V AC/DC 600 Max surrounding air temperature T C 105 A According to series primary Primary current I A P current Secondary supply voltage U V DC 5 C V Output voltage V 0 to 5 out Conditions of acceptability 1 - These devices have been evaluated for overvoltage category III and for use in pollution degree 2 environment. 2 - A suitable enclosure shall be provided in the end-use application. 3 - The terminals have not been evaluated for field wiring. 4 - These devices are intended to be mounted on a printed wiring board of end use equipment. The suitability of the connections (including spacings) shall be determined in the end-use application. 5 - Primary terminals shall not be straightened since assembly of housing case depends upon bending of the terminals. 6 - Any surface of polymeric housing have not been evaluated as insulating barrier. 7 - Low voltage control circuit shall be supplied by an isolating source (such as a transformer, optical isolator, limiting impedance or electro-mechanical relay). Marking Only those products bearing the UR Mark should be considered to be Listed or Recognized and covered under UL s Follow-Up Service. Always look for the Mark on the product. Page 2/11 17September2015/Version 1 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com