Current Transducer HO-P series I = 60, 100, 120, 180, 240, 250 A PN Ref: HO 60-P, HO 100-P, HO 120-P, HO 180-P, HO 240-P, HO 250-P For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Applications Features Open loop multi-range current transducer AC variable speed and servo motor drives Voltage output Static converters for DC motor drives Single power supply +5 V Battery supplied applications Over-current detect 2.93 I (peak value) Uninterruptible Power Supplies (UPS) PN EEPROM Control Switched Mode Power Supplies (SMPS) Galvanic separation between primary and secondary circuit Power supplies for welding applications Low power consumption Combiner box Compact design for THT PCB mounting MPPT. Aperture: 15 8 mm Standards Factory calibrated Dedicated parameter settings available on request EN 50178: 1997 (see page 12). IEC 61010-1: 2010 IEC 61326-1: 2012 Advantages UL 508: 2010. Low offset drift Application Domain Over-drivable V ref 8 mm creepage/clearance Industrial. Fast response. N97.K4.27.000.0 N97.K4.34.000.0 N97.K4.36.000.0 N97.K4.42.000.0 N97.K4.D4.000.0 N97.K4.45.000.0 Page 1/15 16July2015/Version 5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com HO 60 .. 250-P series Absolute maximum ratings Parameter Symbol Unit Value Supply voltage (not destructive) U V 8 C Supply voltage (not entering non standard modes) U V 6.5 C Primary conductor temperature T C 120 B ESD rating, Human Body Model (HBM) U kV 2 ESD Stresses above these ratings may cause permanent damage. Exposure to absolute maximum ratings for extended periods may degrade reliability. UL 508: Ratings and assumptions of certification File E189713 Volume: 2 Section: 5 Standards CSA C22.2 NO. 14-10 INDUSTRIAL CONTROL EQUIPMENT - Edition 11 - Revision Date 2011/08/01 UL 508 STANDARD FOR INDUSTRIAL CONTROL EQUIPMENT - Edition 17 - Revision Date 2010/04/15 Ratings Parameter Symbol Unit Value Primary involved potential V AC/DC 600 Max surrounding air temperature T C 105 A According to series primary Primary current I A P current Secondary supply voltage U V DC 5 C V Output voltage V 0 to 5 out Conditions of acceptability 1 - These devices have been evaluated for overvoltage category III and for use in pollution degree 2 environment. 2 - A suitable enclosure shall be provided in the end-use application. 3 - The terminals have not been evaluated for field wiring. 4 - These devices are intended to be mounted on a printed wiring board of end use equipment. The suitability of the connections (including spacings) shall be determined in the end-use application. 5 - Primary terminals shall not be straightened since assembly of housing case depends upon bending of the terminals. 6 - Any surface of polymeric housing have not been evaluated as insulating barrier. 7 - Low voltage control circuit shall be supplied by an isolating source (such as a transformer, optical isolator, limiting impedance or electro-mechanical relay). 10 - The jumper installed within the primary hole is only intended for fixing the sensor and not for carrying the primary current. Marking Only those products bearing the UR Mark should be considered to be Listed or Recognized and covered under UL s Follow-Up Service. Always look for the Mark on the product. Page 2/15 16July2015/Version 5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com