AC Current transformer TT 100-SD I = 100 A PN Split core transducer for the electronic measurement of AC waveform currents, with galvanic isolation between the primary circuit (power) and the secondary circuit (measurement). Electrical data I Primary nominal current rms 100 At PN Features I Output current 33.33 mA OUT V Output clamping voltage 7.5 V Split core type SZ Overload capability - continuous 300 A P 16 mm sensing aperture for non- - 1 min 4000 A contact measurement Cable output (1m) Isolated plastic case recognized Performance data according to UL 94-V0. X Overall accuracy I , T = 25C < 1 % G PN A Linearity error 0.1 % L TCI Temperature coefficient of I 60 ppm/K Advantages OUT OUT Phase shift 1.5 1 High accuracy and low phase shift BW Frequency bandwidth ( 1dB) 50/60 Hz High isolation between primary and secondary circuits General data Compact case Cost-effective solution T Ambient operating temperature - 25 .. + 70 C A T Ambient storage temperature - 30 .. + 90 C Easy installation. S m Mass 100 g IPxx Protection degree IP40 Applications Power meters Isolation characteristics Current measurement for active 1) V Rated isolation voltage rms 300 V b power calculation with IEC 61010-1 standards and following conditions : Energy sub-meters - Reinforced isolation For energy efficiency monitoring, - Over voltage category CAT III consumption analysis and costs - Pollution degree PD2 allocation - Heterogeneous field 2) Power quality monitoring V Rms voltage for AC isolation test , 50Hz, 1min 3.5 kV d V Impulse withstand voltage 1.2/50s 6.5 kV Condition monitoring w dCp Creepage distance 6 mm (e.g. motor loads such as dCl Clearance distance 6 mm conveyers, pumps or HVAC) CTI Comparative tracking index (Group I) 600 Distributed measurement systems 1) Application domain Notes : If insulated cable is used for the primary circuit, the voltage category could be improved according to the primary cable insulation category Energy and Automation (please refer to the cable manufacturer s indications) 2) between primary (completely filling the hole) and secondary. Page 1/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 071115/5 www.lem.comCurrent transformer TT 100-SD Safety and warning notes In order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions, please read these instructions thoroughly Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the technical specifications. Ensure you get up-to-date technical information that can be found in the latest associated datasheet under www.lem.com. Caution Risk of danger Ignoring the warnings can lead to serious injury and/or cause damage The electric measuring transducer may only be installed and put into operation by qualified personnel that have received an appropriate training. The corresponding national regulations shall be observed during installation and operation of the transducer and any electrical conductor. The transducer shall be used in electric/electronic equipment with respect to applicable standards and safety requirements and in accordance with all the related systems and components manufacturers operating instructions. Caution Risk of electrical shock When operating the transducer, certain parts of the module may carry hazardous live voltage (e.g. primary conductor, power supply). The user shall ensure to take all measures necessary to protect against electrical shock. The transducer is a built-in device containing conducting parts that shall not be accessible after installation. A protective enclosure or additional insulation barrier may be necessary. The transducer shall not be put into operation if the jaw opening is open (split core version) or the installation is not completed. Installation and maintenance shall be done with the main power supply disconnected except if there are no hazardous live parts in or in close proximity to the system and if the applicable national regulations are fully observed. Safe and trouble-free operation of this transducer can only be guaranteed if transport, storage and installation are carried out correctly and operation and maintenance are carried out with care. Page 2/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 071115/5 www.lem.com