Axial Lead & Cartridge Fuses 2AG > Special Fuse > 220 Series PS Pb RoHS E 220 Series, Lead-Free 2AG Special Fuse Description The 220 Series is a 2AG special fuse with various voltage ratings that provide special electric performance as required. Features In accordance RoHS compliant and with Underwriters Lead-free Laboratories Standard Conforms to DENANs UL/CSA/NMX 248-14 Appendix 3 Available in cartridge and axial lead format Agency Approvals with various forming dimensions Agency Agency File Number Ampere Range 0003,0004,0010,0011, Applications E10480 0025,0029,0030,0031,0036 0007,0012,0013,0019, Used as supplementary protection in appliance or E10480 0044,0045,0059,0060,0061 utilization equipment to provide individual protection for Cartridge Version components or internal circuits. NBK200405-E10480A 1A NBK200405-E10480C 1.25A - 3.5A NBK110512-E10480A 4A - 5A NBK190619-E10480A 6A - 7A Additional Information PS E Axial Leaded Version 1A NBK200405-E10480B 1.25A - 3.5A NBK200405-E10480D 4A - 5A NBK110512-E10480B 6A - 7A NBK190619-E10480B Datasheet Resources Samples Accessories 0003,0004,0007,0010, 29862 0011,0013,0019,0029,0044 For recommended fuse accessories for this product series, N/A 0003-0061 see Recommended Accessories section. Electrical Characteristics for Series % of Ampere % of Ampere Rating/ Amp code Opening Time Amp code Opening Time Rating Overload Current 100% 4 hours, Minimum 100% 4 hours, Minimum 0007,0012,0013,0019, 135% 0031,0036,0037,0044, 1 hour, Maximum 150% 0010 15 mins, Maximum 0054,0060,0061 200% 1 sec., Maximum 0.9A 90 secs., Maximum % of Ampere Overload Amp code Opening Time Amp code Opening Time Rating Current 100% 0.6A 0003,0004,0011 90 secs., Maximum 4 hours, Minimum 135% 1 hour, Maximum 0025,0030,0038,0040, 0045,0059 Overload 3 secs., Minimum Amp code Opening Time 200% Current 20 secs., Maximum 0.6A 90 secs., Maximum 2A 0029 2 secs., Maximum 6A 0.5 sec., Maximum 2020 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 01/30/20Axial Lead & Cartridge Fuses 2AG > Special Fuse > 220 Series Electrical Characteristics Max Agency Approvals Ampere Nominal Cold Nominal Voltage Rating Amp Code Interrupting Rating* Resistance Melting PS Rating 2 2 E (A) (Ohms) I t (A sec) (V) 0.35 0003 250 1.3100 0.490 X - - X X 35A 250Vac, 10KA 125Vac 0.35 0004 250 1.3100 0.490 X - - X X 3 0007 350 100A 350Vac, 60A 530Vac 0.0317 4.62 - X X X X 35A 250Vac, 10KA 125Vac, 0.55 0010 250 0.4945 2.04 X - - X X 10KA 125Vdc 0.35 0011 250 35A 250Vac, 10KA 125Vac 1.3100 0.49 X - - X X 2 0012 350 0.0497 1.50 - X X X 100A 350Vac 5 0013 300 0.0186 17.0 - X X X X 3 0019 350 100A 350Vac, 100A 125Vdc 0.0317 4.62 - X X X X 100A 250Vac, 10KA 125Vac, 1.25 0025 250 0.1460 15.4 X - X - X 10KA 125 Vdc 0.35 0029 250 35A 250Vac, 10KA 125Vac 1.3100 0.490 X - - X X 0.375 0030 250 1.1685 0.82 X - - - X 35A 250Vac, 10KA 125Vac, 10KA 125Vdc 0.3 0031 250 0.5900 0.0300 X - - - X 0.5 0036 300 0.2650 0.365 X - - - X 35A 300Vac, 10KA 125Vac 0.75 0037 300 0.1520 1.05 - - - - X 5 0038 250 50A 250Vac 0.0186 267 - - - - X 35A 250Vac, 10KA 125Vac, 0.5 0040 250 0.6935 1.58 - - - - X 10KA 125Vdc 1 0044 350 100A 350Vac 0.1027 2.22 - X X X X 100A 250Vac, 100A 350Vac, 2 0045 350 0.0698 30.0 - X X - X 10KA 125Vac, 10KA 125Vdc 7 0059 350 100A 350Vac / 160A 140Vdc 0.0116 464 - X X - X 0.5 0060 350 0.2650 0.365 - X - - X 35A 350Vac 0.75 0061 350 0.1520 1.05 - X - - X Note *: Interrupting Rating may differ based on Agency Approval. See Agency Approval certificate for more details. Temperature Re-rating Curve Average Time Current Curves 100 10 1 0.1 Note: Rerating depicted in this curve is in addition to the standard derating of 25% for continuous operation. 0.01 0.001 0.1 110 100 1000 CURRENT IN AMPERES 2020 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 01/30/20 TIME IN SECONDS .100A .200A .250A .375A .500A .750A 1.0A 1.5A 2.0A 2.5A 3A 4A 5A 6A 7A 8A 10A