Radial Lead Fuses TE5 Fuse > Time-Lag Fuse > 400 Series PS RoHS Pb E 400 Series, TE5 Fuse, Time-Lag Description The 400 Series TE5 Fuse is a Time-Lag type subminiature fuse that is designed for overcurrent protection. It is rated 250V and meets the requirements of IEC 60127-3. Features Halogen free, Lead-free High Breaking Capacity and RoHS compliant up to 130A at 250VAC Reduced PCB space Internationally approved requirements Recognized to UL/CSA/ Direct solderable or plug- NMX 248-1 and UL/CSA/ in versions NMX 248-14 Agency Approvals Low internal resistance Conforms to IEC/EN/J/K 60127-1 and EC/EN/J/K Shock safe casing Agency Agency File Number Ampere Range 60127-3 Vibration resistant E67006 0.50A 6.3A JET1896-31007-2001 1A 5A PS E JET1896-31007-1006 6.3A 40026355 0.50A 6.3A Applications N/A 0.5A - 6.3A Battery chargers Power supplies 2020970207000059 0.50A 6.3A Consumer electronics Industrial controllers SU05024-9004 0.50A 0.80A SU05024-9003 1A 2.5A SU05024-9001 3.15A SU05024-10003 4A 5A SU05024-9002 6.3A Additional Information Electrical Characteristics % of Ampere Rating Opening Time 150% 1 Hour, Minimum 210% 120 Secs., Maximum Datasheet Resources Samples 275% 400 ms, Minimum 10 Secs., Maximum 400% 150 ms, Minimum 3 Secs., Maximum 1000% 20 ms, Minimum 150 ms, Maximum Electrical Characteristics Agency Approvals Voltage Power Melting Rated Nominal Cold Amp Rated Breaking Drop Dissipation Integral Voltage Resistance PS Code Current Capacity 1.0I 1.0I 10I E N N N (V) (Ohms) 2 max. (mV) max. (mW) max. (A s) 0.5 0.5A 250 0.1950 165 297 2.170 x - x x x x 0800 0.8A 250 0.1003 116 387 6.720 x - x x x x 1100 1.00A 250 0.0808 89 432 10.70 x x x x x x 1125 1.25A 250 0.0562 76 411 14.44 x x x x x x 1160 1.60A 250 0.0384 76 601 21.75 x x x x x x 130A 1200 2.00A 250 0.0292 75 758 46.00 x x x x x x 250VAC 1250 2.50A 250 0.0216 61 683 61.94 x x x x x x 1315 3.15A 250 0.0167 55 921 101.61 x x x x x x 1400 4.00A 250 0.0124 65 936 133.40 x x x x x x 1500 5.00A 250 0.0098 56 948 216.50 x x x x x x 1630 6.30A 250 0.0072 48 926 323.08 x x x x x x * Per VDE, approved breaking capacity is at 100A, 250VAC 2020 Littelfuse, Inc. Specifications are subject to change without notice. Revised: BA.08/18/20Radial Lead Fuses TE5 Fuse > Time-Lag Fuse > 400 Series Temperature Re-rating Curve Average Time Current Curves DE-RATING CURVE 140 120 100 100 80 60 10 23C 40 20 1 0 -40 -20 0 20 40 60 80 AMBIENT TEMPERATURE (C) 0.1 Note 1. Rerating depicted in this curve is in addition to the standard derating of 25% for continuous operation. 0.01 0.001 0 1 10 100 1000 CURRENT IN AMPERES Soldering Parameters - Wave Soldering Recommended Process Parameters: 300 280 260 Wave Parameter Lead-Free Recommendation 240 220 200 Preheat: 180 (Depends on Flux Activation Temperature) (Typical Industry Recommendation) 160 Temperature Minimum: 100C 140 120 Temperature Maximum: 150C 100 80 Preheat Time: 60-180 seconds 60 Solder Pot Temperature: 260C Maximum 40 20 Solder Dwell Time: 2-5 seconds 0 Recommended Hand-Solder Parameters: Solder Iron Temperature: 350C +/- 5C Time (Seconds) Heating Time: 5 seconds max. Preheat Time Cooling Time Note: These devices are not recommended for IR or Convection Reflow process. Dwell Time 2020 Littelfuse, Inc. Specifications are subject to change without notice. Revised: BA.08/18/20 Temperature ( ) - Measured on bottom side of board PERCENT OF RATING 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 TIME IN SECONDS 0.5A 0.8A 1A 1.25A 1.6A 2A 2.5A 3.15A 4A 5A 6.3A