Hall Effect Sensor Datasheet 55100 Sensor Miniature Flange Mounting Proximity Description The 55100 is a miniature flange mounting hall effect sensor 25.5mm (1.004) x 11.00m (0.433) and only 3.00mm (0.118) high with a choice of digital or programmable analog outputs. It is available as three-wire (voltage output) or two-wire (current output) versions. Its case design enables screw or adhesive mounting and capable of switching up to 24Vdc and 20mA. It comes with a range of sensitivity and cable length options. Features & Benefits Magnetically operated Vibration 50g max. 50- position sensor 2,000Hz Digital or programmable Shock 150g max. 11ms analog types available Sine Medium, high or High switching speed up to programmable sensitivities 12kHz Additional Information Three-wire (voltage output) Long life - up to 20 billion or two-wire (current output) operations versions Operates in static or dynamic Reverse/Over voltage magnetic field protection RoHS compliant Built in temperature compensation Resources Accessories Samples Applications Position and limit sensing Commutation of brushless DC motors RPM measurement Angle sensing Flow metering Magnetic encoders Dimensions mm (inch) 11.00 (.433) 3.00 Excluding encapsulant (.118) 300 25.50 (1.004) (11.81) 6.35 NOM. (.250) 7.50 (.295) 16.60 (.654) Center of Sensitivity 3.30x4.20 TYP. SLOT (.130X.165) 1.50 (2.00) (.059) Note: Two-wire version illustrated 2021 Littelfuse, Inc. 1 Specifications are subject to change without notice. Revised GD.04/12/21Hall Effect Sensor Datasheet 55100 Sensor Miniature Flange Mounting Proximity Block Diagram Two-wire Version Three-wire Version VDD VDD VDD Pin 1 Pin 1 (Red) (Red) Hall Current Hall Rpu Switch Comparator Switch Comparator Output Plate Source Plate Cn Cn Clock Clock OUT GND GND Pin 3 Pin 2 Pin 2 (Blue) (Black) (Black) Three-wire Analog Version OUT VDD Pin 3 (Blue) Pin 1 (Red) Hall Switch Comparator Output Plate Cn Cn Clock GND Pin 2 (Black) Note: Add capacitors Cn as shown, 0.1 uF, close to the sensor for transient suppression Notes: 1. Add capcitor Cn as shown, close to the sensor, for transient suppression if required. 2. Add pull-up resistor Rpu as shown for sinking output. The Rpu value should be calculated using your supply voltage while keeping the ON state current at a level below the maximum. Rpu = VDD/Io Rpu = 12Vdc/10mA = 1.2kOhm T1 - Electrical Ratings 2-Wire Hall Switch (2M) Hall Type Digital Switch 2-Wire (Current Output) Absolute Ratings Vdc -18 to +28 1 Supply Voltage Operate Vdc +3 to +24 Overvoltage Protection Vdc - max 32 Hall OFF mA 5.0 to 6.9 Current Consumption Hall ON mA 12.0 to 17.0 Switching Speed - kHz 12 Temperature Operating C -40 to + 100 Notes: 1. It is assumed the product will operate within the normal Supply Voltage of +24Vdc maximum. T2 - Electrical Ratings 3-Wire Hall Switch & Analog Programmable (3H, 3M, & AP) 2 Hall Type Digital Switch 3 - Wire (Voltage Output) AP - Analog (Programmable Only) Absolute Ratings Vdc -18 to +28 8.5 1 Supply Voltage Operate Vdc 2.7 to 24 4.5 - 5.5 Overvoltage Protection Vdc - max 32 16.0 Output High Voltage Min Vdc Sinking Output 0.2 Output Low Voltage Max Vdc 0.4 20mA 4.80 Output Current Max mA 25 -1.0 to + 1.0 (continuously on) Current Consumption - mA 1.1 to 2.4 5.0 to 10.0 (from Supply) Switching Speed - kHz 12 2 Temperature Operating C -40 to +100 -40 to +100 Notes: 1. It is assumed the product will operate within the normal Supply Voltage of +24Vdc maximum. 2. Sensor Voltage Output can be reprogrammed to best fit customer application (see LF Application Note) 2021 Littelfuse, Inc. 2 Specifications are subject to change without notice. Revised GD.04/12/21