CONTACTORS 1 & 2 Pole Contactor 2040 FLA HCC Series S p eci fi catio ns Initial Dielectric Strength Between Contacts & Coils: 2,200 VAC Between Poles: 2,200 VAC (includes shunt) Between Open Contacts: 2,200 VAC (no shunt) Arc Cover Optional on 2030 FLA Standard on 40 FLA Insulation System 130C Class B Temperature Range -40C to +65C -40F to +150F Unit Weight 1 Pole 8 oz 2 Pole 9.6 oz Power Pole Terminations 10-32 screw or box lug Wire Size 10-32 screw 16-8 ( 8 must use ring terminal) 1 & 2 pole contactors are typically used in residential applications. Box lug 14-4 These contactors utilize one wire to control electrical current Recommended Tightening Torque direction. Our engineers and quality specialists provide services 10-32 screw: 22 in. lbs Box lug: 40 in. lbs that meet or exceed customer requirementsall products undergo in-house testing and validation. We carry extensive Quick Connects inventory to meet delivery schedules. Coil terminals: Dual: .250 QC Power terminals: Features 1 Pole: Dual or Quad .250 QC 2 Pole: Dual or Quad .250 QC 1 Pole NO with or without shunt 2 Pole NO Silver Cadmium Oxide Contacts Dimensions (inches mm ) UL 508 File No. E227250 1 & 2 Pole dimensions are the same Semko/CE File No. EN 60947-4-1:2001 CSA File No. 221260 (1456104) Multiple mounting and termination options available, contact us for more information. We can custom engineer a solution to meet any need. Just ask. 815.626.5170 HartlandControls.comCONTACTORS 1 & 2 Pole Contactor 2040 FLA HCC Series 1 Pole Contactors 20 30 120 100 80 25 35 150 125 100 30 40 180 150 120 40 50 240 200 160 2 Pole Contactors 20 30 120 100 80 25 35 150 125 100 30 40 180 150 120 40 50 240 200 160 Suitable for use on a circuit capable of delivering not more than 5k rms symmetrical amperes, 600 Volts maximum at 400% of fuse and circuit breaker. Suitable for use on a circuit capable of delivering not more than 100k rms symmetrical amperes as shown. Maximum Circuit Breaker Any Listed Fuse (except as noted) 480 Volts Maximum Minimum Enclosure Volume 600 Volts Maximum Minimum Enclosure Volume 00, 40 80 A 144 cu. in. 60 A 01, 41 80 A 144 cu. in. 60 A 96 cu. in. (1 & 2 Pole) 02, 42 80 A 144 cu. in. 60 A 144 cu. in. (3 & 4 Pole) 100 A max. Class J Fuse (1 & 2 Pole) 04, 44 100 A 144 cu. in. 100 A (3 & 4 Pole) Note: for a circuit capable of delivering more than 5k rms symmetrical amperes, the equipment enclosure must have a minimum of four fastening points or a piano hinge and two fastening points. Multiple mounting and termination options available, contact us for more information. 2019 Hartland Controls Printed in USA All rights reserved PS0100310171000