Surge Protection Module LED Lighting Surge Protection Module > LSP05G Europe Version RoHS LSP05G European Version Module Series Description Littelfuses LSP05G European version thermally protected Surge Protective Device is a self-protected device specially designed to be used in outdoor and commercial LED lighting fixtures for transient overvoltage protection. It has been developed with Littelfuses thermally protected varistor technology. Its built-in thermal disconnect function provides additional protection to prevent catastrophic failure and fire hazard even under extreme circumstances of varistor end-of- life or sustained over-voltage conditions. It also provides high line-to-earth/ground resistance, facilitating faster production line testing. LSP05G series connected option allows clear indication of thermal fault protection by disconnecting power to the Agency Approvals luminaire, thereby signaling SPD module replacement. The LSP05G Surge Protective Device facilitates product Agency Standard Agency File Number compliance to IEEE C62.41.2 Location Category C Low. UL1449 E320116 Applications Features Maximum Discharge NL-37684 available for 240V Outdoor and Commercial Wall wash lighting Current 10kA, 8/20s and NL-40516 for 277V LED Lighting Parking garage lighting Meets ANSI C136.2 Compact form factor Roadway lighting Flood lighting Enhanced Level with mounting tabs Traffic lighting Tunnel lighting 10kV/5kA and IEEE 240Vac and 277Vac Digital signage Street lighting C62.41.2 Location are available for Class I Category C Low and Class II installation Exposure based on IEC luminaire Thermally Protected protection classes Additional Information Varistor technology and are marked CE Parallel and Series Series connected Connected SPD Options Varistor thermal protection indication IP66 Water-proof by removal of power and Dust-proof Datasheet Resources Samples to luminaire UL1449 Recognized High line-to-earth/ IEC 61643-11 Class ground resistance II and EN 61643-11 RoHS compliant Type 2 compliant. IEC CB Scheme Certificate Absolute Maximum Ratings For ratings of individual members of a series, see Device Ratings and Specifications chart LSP05G Series Units Continous: Max AC Voltage Range (V ) 275 to 320 V M(AC)RMS Continuous Current 5 A Transient: Maximum Discharge Current, 8/20s Waveform (Imax) 10,000 A Nominal Discharge Current, 8/20s Waveform (In) 5,000 A Operating Ambient Temperature Range (TA) -45 to +85 C Storage Temperature Range (T ) -45 to +90 C STG Isolation Voltage Capability (When the thermal disconnect opens) 600 V Insulation Resistance >1,000 M CAUTION: Stresses above those listed inAbsolute Maximum Rating may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. 2020 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 02/21/20Surge Protection Module LED Lighting Surge Protection Module > LSP05G Europe Version LSP05G European Version Series Device Ratings & Specifications Maximum Nominal Safety Compliance Operating 1 4 5 Parallel/ MCOV/U Discharge Discharge MLV U C P Part Number Voltage IEC/ Luminaire 2 3 Series (VAC) Current Current (V) (V) UL1449 6 (VAC) EN61643-11 Class I (A) I (A) max n L-N:970 L-N:1100 LSP05G240PX3333 P 240 275 10,000 5,000 L-G:1410 L-G:1600 I X N-G:1410 N-G:1600 L-N:970 L-N:1100 LSP05G240PX3316 P 240 275 10,000 5,000 L-G:1410 L-G:1600 II X N-G:1410 N-G:1600 L-N:970 L-N:1100 LSP05G240SX3333 S 240 275 10,000 5,000 L-G:1410 L-G:1600 X I X N-G:1410 N-G:1600 L-N:970 L-N:1100 LSP05G240SX3316 S 240 275 10,000 5,000 L-G:1410 L-G:1600 X II X N-G:1410 N-G:1600 L-N: 1270 L-N:1200 LSP05G277PX3333 P 277 320 10,000 5,000 L-G: 1400 L-G:1600 I X N-G: 1510 N-G:1600 L-N: 1270 L-N:1200 LSP05G277PX3316 P 277 320 10,000 5,000 L-G: 1400 L-G:1600 II X N-G: 1510 N-G:1600 L-N: 1270 L-N:1200 LSP05G277SX3333 S 277 320 10,000 5,000 L-G: 1400 L-G:1600 X I X N-G: 1510 N-G:1600 L-N: 1270 L-N:1200 LSP05G277SX3316 S 277 320 10,000 5,000 L-G: 1400 L-G:1600 X II X N-G: 1510 N-G:1600 Glossary: 1. MCOV/U : Maximum Continuous Operating Voltage - maximum r.m.s. voltage that could be continuously applied to the SPD. C 2. Maximum Discharge Current Imax (A): The maximum discharge current is a measure of the SPDs maximum capability single impulse of discharge current uses the 8/20s current waveform. 3. Nominal Discharge Current In (A): The nominal discharge current is a measure of the SPDs endurance capability 15 impulses of discharge current uses the 8/20s current waveform. 4. MLV: UL1449 Measured limiting voltage the highest value of residual voltage measurements during the application of impulses of 8/20s nominal discharge current (In) an average voltage value of 15 impulses 5. Up: IEC 61643-11 Voltage protection level the highest value of residual voltage measurements during the application of impulses of 8/20s nominal discharge current (In) a rounding voltage value of maximum measurement. 6. Series module used in parallel connection for indication circuit connection. 7. LSP05G240S & LSP05G277S are certified by DEKRA with below IEC 61643-11 specifications. LSP05G240S Specification Parameter Value Unit Condition Temporary overvoltage TOV U 337 V LV system fault 255 V x 1.32 at t = 5 s, TN power grid T T Temporary overvoltage TOV U 442 V LV system fault 255 V x 1.732 at t = 120 min, TN power grid T T Power grids - TN - - Backup fuse - 16 A max., gG fuse Optical, light ON: SPD is functional End of life indication - yes - Light OFF: SPD has reached end-of-life Max earth leakage current at Uc 50 A Max. rms, to GND LSP05G277S Specification Parameter Value Unit Condition Temporary overvoltage TOV U 403 V LV system fault 305 V x 1.32 at t = 5 s, TN power grid T T Temporary overvoltage TOV U 529 V LV system fault 305 V x 1.732 at t = 120 min, TN power grid T T Power grids - TN - - Backup fuse - 20 A max., gG fuse Optical, light ON: SPD is functional End of life indication - yes - Light OFF: SPD has reached end-of-life LSP05G Protection Levels Up LSP05G240S LSP05G277S Ic 8/20 S Differential mode U2 Common mode U1/U2 Ic 8/20 S Differential mode U2 Common mode U1/U2 5kA 970V 1600V/1410V 5kA 1130V 1600V/1410V Notes: It is normal practice to disconnect components that intentionally breakdown between Line and Protective Earth, otherwise the apparent leakage current measured by the Hi-Pot tester may incorrectly be judged a failure. Maximum Discharge Current Imax (A): The maximum discharge current is a measure of the SPDs maximum capability single impulse of discharge current uses the 8/20s current waveform. All Devices pass maximum discharge current with possible, safe opening of thermal disconnect. 2020 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 02/21/20