Surge Protection Module LED Lighting Surge Protection Module > LSP05G RoHS LSP05G Module Series Description Littelfuse s LSP05G thermally protected surge protection device specially designed to be used in outdoor, commercial, and industrial LED lighting fixtures. It utilizes Littelfuse s thermally protected varistor technology which acts as a self-protector, helping prevent end-of-life issues related to varistors as well as issues related to sustaining over-voltage conditions. It also provides high line-to- earth/ground resistance, facilitating faster production line testing. LSP05G series connected option allows clear indication of thermal fault protection by disconnecting power to luminaire, thereby signaling SPD module replacement. The LSP05G Surge Protective Device facilitates customers product compliance to IEEE C62.41.2 Location Category C Low ANSI C136.2 and US Dept. of Energy MSSLC Model Spec. Agency Approvals Features IEC CB Scheme Certificate Maximum Discharge Agency Standard Agency File Number Current (I ) 10kA, 8/20s NL-37684 available for 240V max + and NL-40516 for 277V UL1449 Meets ANSI C136.2 E320116 for 120V, 240V, 277V Only Enhanced Level 10kV/5kA, Compact form factor ++ IEEE C62.41.2 Location with mounting tabs IEC 61643-11 NL-37684 and NL-40516 Category C Low Exposure 240Vac and 277Vac are + = For 120V, 240V and 277V and US Dept. of Energy ++ = For 240V and 277V, respectively CE compliant and available MSSLC Model Spec. for Class I and Class II Applications Thermally Protected installation based on IEC Varistor technology luminaire protection classes Outdoor and Commercial Parking garage lighting Parallel and Series Series connected LED Lighting Flood lighting Connected SPD Options Varistor thermal Roadway lighting protection indication Tunnel lighting IP66 Water-proof by removal of power and Dust-proof Traffic lighting Street lighting to luminaire UL1449 Recognized Digital signage High line-to-earth/ Industrial high-bay (120Vac, 240Vac and ground resistance Wall wash lighting and low-bay lighting 277Vac only) RohS compliant Series- connected option Additional Information for 240V and 277V is IEC 61643-11 Test Class II and EN 61643-11 Type 2 compliant. Datasheet Resources Samples Absolute Maximum Ratings For ratings of individual members of a series, see Device Ratings and Specifications chart LSP05G Series Units Continous: Max AC Voltage Range (VM(AC)RMS) 150 to 510 V Continuous Current 5 A Transient: Maximum Discharge Current, 8/20s Waveform (Imax) 10,000 A Nominal Discharge Current, 8/20s Waveform (I ) 5,000 A n Operating Ambient Temperature Range (TA) -45 to +85 C Storage Temperature Range (TSTG) -45 to +90 C Isolation Voltage Capability (When the thermal disconnect opens) 600 V Insulation Resistance >1,000 M CAUTION: Stresses above those listed inAbsolute Maximum Rating may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. 2019 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 12/03/19Surge Protection Module LED Lighting Surge Protection Module > LSP05G LSP05G Series Device Ratings & Specifications Maximum Nominal Safety Compliance Typical Typical 1 Operating MCOV/UC Discharge Discharge 5 4 Part Number MLV Up 2 3 Voltage (VAC) (VAC) Current Current IEC/EN 61643- (V) (V) UL1449 6 & 7 I (A) I (A) max n 11 L-N:600 L-N:700 LSP05G120* 120 150 10,000 5,000 L-G:1410 L-G:1600 X N-G:1410 N-G:1600 L-N:970 L-N:1100 LSP05G240* 240 275 10,000 5,000 L-G:1410 L-G:1600 X X N-G:1410 N-G:1600 L-N:1270 L-N: 1200 LSP05G277* 277 320 10,000 5,000 L-G:1400 L-G: 1600 X X N-G:1510 N-G:1600 L-N: 1530 L-N: 1600 LSP05G347* 347 420 10,000 5,000 L-G: 1550 L-G: 1700 N-G: 1410 N-G: 1600 L-N: 1800 L-N: 2100 LSP05G480* 480 510 10,000 5,000 L-G: 1900 L-G: 2000 N-G: 1410 N-G: 1600 L-N: 1800 L-N: 2100 LSP05G480*H 480 510 10,000 5,000 L-G: 3090 L-G: 3700 N-G: 3090 N-G: 3700 * = S or P with 1500Vac Hi-Pot withstand capability in common mode (L-G and N-G) Glossary: 1. MCOV/U : Maximum Continuous Operating Voltage - maximum r.m.s. voltage that could be continuously applied to the SPD. C 2. Maximum Discharge Current Imax (A): The maximum discharge current is a measure of the SPDs maximum capability single impulse of discharge current uses the 8/20s current waveform. All Devices pass maximum discharge current with possible, safe opening of thermal disconnect. 3. Nominal Discharge Current In (A): The nominal discharge current is a measure of the SPDs endurance capability 15 impulses of discharge current uses the 8/20s current waveform. 4. MLV: UL1449 Measured limiting voltage the highest value of residual voltage measurements during the application of impulses of 8/20s nominal discharge current (In) an average voltage value of 15 impulses 5. Up: IEC 61643-11 Voltage protection level the highest value of residual voltage measurements during the application of impulses of 8/20s nominal discharge current (In) a rounding voltage value of maximum measurement. 6. Series module used in parallel connection for indication circuit connection. 7. LSP05G240S & LSP05G277S are certified by DEKRA with below IEC 61643-11 specifications LSP05G240S Specification Parameter Value Unit Condition Temporary overvoltage TOV U 337 V LV system fault 255 V x 1.32 at t = 5 s, TN power grid T T Temporary overvoltage TOV U 442 V LV system fault 255 V x 1.732 at t = 120 min, TN power grid T T Power grids TN Backup fuse 16 A max., gG fuse Optical, light ON: SPD is functional End of life indication yes Light OFF: SPD has reached end-of-life Max earth leakage current at Uc 50 A Max. rms, to GND LSP05G277S Specification Parameter Value Unit Condition Temporary overvoltage TOV U 403 V LV system fault 305 V x 1.32 at t = 5 s, TN power grid T T Temporary overvoltage TOV U 529 V LV system fault 305 V x 1.732 at t = 120 min, TN power grid T T Power grids TN Backup fuse 20 A max., gG fuse Optical, light ON: SPD is functional End of life indication yes Light OFF: SPD has reached end-of-life 2019 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 12/03/19