Thyristors 16 Amp Alternistor (High Commutation) Commutation Triac for LED Dimmer Application RoHS Q6016xH1LED Series Description Q6016LH1LED series is designed to meet low load current characteristics typical in LED lighting applications. By keeping holding current at 5mA maximum, this Triac series is characterized and specified to perform best with LED loads. The Q6016LH1LED series is best suited for LED dimming controls to obtain the lowest levels of light output with a minimum probability of flickering. Q6016LH1LED series is offered in the industry standard TO-220AB package with an isolated mounting tab that makes it best suited for adding an external heat sink. Agency Recognitions Features & Benifits Agency Agency File Number A s low as 5 mA max 2 5 0 0 V min isolation AC holding current between mounting tab E71639 and active terminals L-Package is UL Recognized for 2500Vrms Improves margin of safe operation with less heat d i/dt performance of Main Features sinking required 100A/s Enable survivability Symbol Value Unit UL Recognized to UL 1557 of typically LED load I 16 A P rovides full control operating characteristics T(RMS) of light out put at the V /V 600 V DRM RRM Simplicity of circuit design extreme low end of load I 5 mA GT & layout conditions. Schematic Symbol Applications Excellent for AC switching and phase control applications such as heating, lighting, and motor speed controls. MT2 MT1 Typical applications are AC solid-state switches,lighting controls with LED lamp loads, small low current motor in power tools, lower current motor in home/brown goods appliances. G Internally constructed isolated packages are offered for ease of heat sinking with highest isolation voltage. 2019 Littelfuse, Inc Specifications are subject to change without notice. Revised: 10/15/19Thyristors 16 Amp Alternistor (High Commutation) Commutation Triac for LED Dimmer Application Absolute Maximum Ratings Symbol Parameter Value Unit I RMS on-state current (full sine wave) - T = 90C 16 A T(RMS) C f = 50 Hz t = 20 ms 167 Non repetitive surge peak on-state current I A TSM (full cycle, T initial = 25C) J f = 60 Hz t = 16.7 ms 200 2 2 2 I t I t Value for fusing - t = 8.3 ms 166 A s p di/dt Critical rate of rise of on-state current f = 60 Hz T = 125C 100 A/s J t 10 s p I Peak gate trigger current T = 125C 2.0 A GTM J I I GT GTM P Average gate power dissipation T = 125C 0.5 W G(AV) J T Storage temperature range - -40 to 150 C stg T Operating junction temperature range - -40 to 125 C J Electrical Characteristics (T = 25C, unless otherwise specified) J Symbol Test Conditions Quadrant Qxx16LH1 Unit I I II III MAX. 5 mA GT V = 12V R = 60 D L V I II III MAX. 1.3 V GT V V = V R = 3.3 k T = 125C I II III MIN. 0.2 V GD D DRM L J I I = 20mA MAX. 5 mA H T dv/dt V = V Gate Open T = 125C MIN. 45 V/s D DRM J (dv/dt)c (di/dt)c = 8.6 A/ms T = 125C MIN. 2 V/s J t I = 2 x I PW = 15s I = 22.6 A(pk) TYP. 3 s gt G GT T Static Characteristics Symbol Test Conditions Value Unit V I = 22.6A t = 380 s MAX. 1.60 V TM TM p T = 25C 10 A I J DRM V = V / V MAX. D DRM RRM I T = 125C 2 mA RRM J Thermal Resistances Symbol Parameter Value Unit R Junction to case (AC) 2.1 C/W (JC) R Junction to ambient 50 C/W (J-A) Note: xx = voltage 2019 Littelfuse, Inc Specifications are subject to change without notice. Revised: 10/15/19