Thyristors
15 Amp Standard & 16 Amp Alternistor (High Commutation) Triacs
RoHS
Qxx15xx & Qxx16xHx Series
Description
This 15 Amp and 16 Amp bi-directional solid state switch
series is designed for AC switching and phase control
applications such as motor speed, temperature modulation
controls, lighting controls, and static switching relays.
Standard type devices normally operate in Quadrants I & III
triggered from AC line.
Standard alternistor triac components operate with in-phase
signals in Quadrants I or III and ONLY unipolar negative gate
pulses for Quadrant II or III. The alternistor triac will not
operate in Quadrant IV. These are used in circuit applications
requiring a high dv/dt capability.
Agency Approval
Features & Benefits
R oHS-compliant contact bounce that
Agency Agency File Number
create voltage transients
E71639* Glass passivated
junctions No contacts to wear
* - L Package only
out from reaction of
Voltage capability up to
switching events
1000 V
Restricted (or limited) RFI
Surge capability up to
Main Features
generation, depending
200 A
on activation point in sine
Symbol Value Unit
T he L-package has
wave
I 15 or 16 A an isolation rating of
T(RMS)
Requires only a small
2500V
V /V 400, 600, 800 or 1000 V RMS
DRM RRM
gate activation pulse in
Solid-state switching
I 10, 20, 35, 50 or 80 mA each half-cycle
GT (Q1)
eliminates arcing or
Schematic Symbol Applications
Excellent for AC switching and phase control applications
such as heating, lighting, and motor speed controls.
MT2 MT1
Typical applications are AC solid-state switches, light
dimmers, power tools, lawn care equipment, home/brown
goods and white goods appliances.
G
Alternistor Triacs (no snubber required) are used in
applications with extremely inductive loads requiring
highest commutation performance.
Additional Information
Internally constructed isolated packages are offered for
ease of heat sinking with highest isolation voltage.
Datasheet Resources Samples
2019 Littelfuse, Inc
Specifications are subject to change without notice.
Revised: BO.12/11/20Thyristors
15 Amp Standard & 16 Amp Alternistor (High Commutation) Triacs
Absolute Maximum Ratings Standard Triac
Symbol Parameter Value Unit
Qxx15Ly T = 80C
C
I RMS on-state current (full sine wave) 15 A
T(RMS) Qxx15Ry
T = 90C
C
Qxx15Ny
f = 50 Hz t = 20 ms 167
Non repetitive surge peak on-state current
I A
TSM
(full cycle, T initial = 25C)
f = 60 Hz t = 16.7 ms 200
J
2 2 2
I t I t Value for fusing - t = 8.3 ms 166 A s
p
di/dt Critical rate of rise of on-state current f = 120 Hz T = 125C 100 A/s
J
I Peak gate trigger current t =20s T = 125C 4 A
GTM p J
P Average gate power dissipation T = 125C 0.5 W
G(AV) J
T Storage temperature range - -40 to 150 C
stg
T Operating junction temperature range - -40 to 125 C
J
Note: xx = voltage/10, y = sensitivity
Absolute Maximum Ratings Alternistor Triac (3 Quadrants)
Symbol Parameter Value Unit
Qxx16LHy T = 80C
C
I RMS on-state current (full sine wave) 16 A
T(RMS) Qxx16RHy
T = 90C
C
Qxx16NHy
f = 50 Hz t = 20 ms 167
Non repetitive surge peak on-state current
I A
TSM
(full cycle, T initial = 25C)
f = 60 Hz t = 16.7 ms 200
J
2 2 2
I t I t Value for fusing t = 8.3 ms 166 A s
p
di/dt Critical rate of rise of on-state current f = 120 Hz T = 125C 100 A/s
J
I Peak gate trigger current t =20s T = 125C 4 A
GTM p J
P Average gate power dissipation T = 125C 0.5 W
G(AV) J
T Storage temperature range -40 to 150 C
stg
T Operating junction temperature range -40 to 125 C
J
Note: xx = voltage/10, y = sensitivity
Electrical Characteristics (T = 25C, unless otherwise specified) Standard Triac
J
Symbol Test Conditions Quadrant Value Unit
I V = 12V R = 60 I II III MAX. 50 mA
GT D L
V V = 12V R = 60 I II III MAX. 2.0 V
GT D L
V V = V R = 3.3 k T = 125C I II III MIN. 0.2 V
GD D DRM L J
I I = 100mA MAX. 70 mA
H T
400V 275
V = V Gate Open T = 125C 600V 225
D DRM J
dv/dt MIN. V/s
800V 200
V = V Gate Open T = 100C 1000V 200
D DRM J
(dv/dt)c (di/dt)c = 8.1 A/ms T = 125C MIN. 4 V/s
J
t I = 2 x I PW = 15s I = 22.6 A(pk) TYP. 4 s
gt G GT T
2019 Littelfuse, Inc
Specifications are subject to change without notice.