Surge Protection Devices SPD2 3P+0 SERIES Class II/Type 2/Type 1 CA Pluggable Multi-Pole Description Surge protection devices (SPDs) provide equipment protection from transient overvoltage events lasting micro-seconds. By Visual Life limiting the overvoltage to the equipment during these events, Indicator costly damage and downtime can be mitigated. The surge protection devices for the 3+0 configuration are available for 120 V to 600 V nominal voltage sub-distribution board applications. Pluggable RC Connector Features & Benefits FEATURES BENEFITS Ensures low-residual voltage during high-energy Capability to clamp and Internal Configuration surge events and higher nominal discharge current withstand high-energy to prevent disruption, downtime, and degradation or transients damage to equipment L1 L2 L3 UL Recognized and One component can be utilized globally, reducing VDE-IEC compliant in inventory needs and simplifying allocation of parts single part number Interlocking tab TD TD TD Secures module to withstand vibration mechanism No additional overcurrent protection Reduces the number of components and costs devices required in required for protection UL applications Compact footprint Increases panel design flexibility RC 14 11 12 Quick visual determines module replacement status Visual life indicator to avoid loss of protection Legend Fast and simple to replace, minimizing maintenance L Line RC Remote Contacts Pluggable modules and downtime. No tools required TD Thermal Disconnection N Neutral Thermal protection Eliminates catastrophic failure Protective Earth IP20 protection rating Finger-safe design increases worker protection Module & Base Ordering Information IEC Electrical UL Electrical Single Unit Ordering Number Weight SPD2-150-3P0-R 120 V 150 V 20 kA 50 kA 1250 V 25 kA / 50 kA 229 V 229 V / Withstand 150 V 600 V 20 kA 200 kA 355 g (0.783 lb) SPD2-300-3P0-R 240 V 300 V 20 kA 50 kA 1500 V 25 kA / 50 kA 337 V 442 V / Safe Fail 300 V 900 V 20 kA 150 kA 376 g (0.829 lb) SPD2-350-3P0-R 277 V 350 V 20 kA 50 kA 1750 V 25 kA / 50 kA 403 V 529 V / Safe Fail 350 V 1000 V 20 kA 200 kA 391 g (0.862 lb) SPD2-480-3P0-R 400 V 480 V 20 kA 50 kA 2300 V 25 kA / 50 kA 581 V 762 V / Safe Fail 480 V 1500 V 20 kA 200 kA 406 g (0.896 lb) SPD2-550-3P0-R* 480 V 550 V 20 kA 50 kA 2500 V 25 kA / 50 kA 697 V 915 V / Safe Fail 550 V 2000 V 20 kA 200 kA 414 g (0.913 lb) SPD2-750-3P0-R 600 V 750 V 20 kA 35 kA 3400 V 25 kA / 50 kA 871 V 1143 V / Safe Fail 750 V 2500 V 20 kA 200 kA 454 g (1.001 lb) Littelfuse.com/spd 2019 Littelfuse, Inc. 1 of 2 Rev: 1-A-061719 Nominal AC Voltage (50/60Hz) (U /U ) o n Maximum Continuous Operating AC Voltage (U ) c Nominal Discharge Current (8/20 s) (I ) n Maximum Discharge Current (8/20 s) (I ) max Voltage Protection Level (U ) p Short-Circuit AC Current Rating (I ) SCCR TOV Withstand 5 s (U ) T TOV 120 min (U ) / Mode T Maximum Continuous AC Operating Voltage (MCOV) Voltage Protection Rating (VPR) Nominal Discharge Current (8/20 s) (I ) n Short-Circuit Current Rating (SCCR)Surge Protection Devices SPD2 3P+0 SERIES Module & Base Part Numbering System Module Only Part Numbering System SPD2 VVV XPZ R SPD2 VVV M Optional Remote Module Only Series Contact Series Maximum Continuous Neutral Maximum Continuous Operating AC Voltage (1=yes or 0=no) Operating AC Voltage Number of Poles Replacement Module Ordering Information IEC Electrical UL Electrical Single Unit Ordering Number Weight SPD2-150-M 120 V 150 V 20 kA 50 kA 1250 V 25 kA / 50 kA 229 V 229 V / Withstand 150 V 600 V 20 kA 200 kA 54 g (0.120 lb) SPD2-300-M 240 V 300 V 20 kA 50 kA 1500 V 25 kA / 50 kA 337 V 442 V / Safe Fail 300 V 900 V 20 kA 150 kA 61 g (0.135 lb) SPD2-350-M 277 V 350 V 20 kA 50 kA 1750 V 25 kA / 50 kA 403 V 529 V / Safe Fail 350 V 1000 V 20 kA 200 kA 66 g (0.146 lb) SPD2-480-M 400 V 480 V 20 kA 50 kA 2300 V 25 kA / 50 kA 581 V 762 V / Safe Fail 480 V 1500 V 20 kA 200 kA 71 g (0.157 lb) SPD2-550-M* 480 V 550 V 20 kA 50 kA 2500 V 25 kA / 50 kA 697 V 915 V / Safe Fail 550 V 2000 V 20 kA 200 kA 74 g (0.163 lb) SPD2-750-M 600 V 750 V 20 kA 35 kA 3400 V 25 kA / 50 kA 871 V 1143 V / Safe Fail 750 V 2500 V 20 kA 200 kA 87 g (0.192 lb) Specifications Housing Material Thermoplastic: Extinguishing Degree Network Systems IT, TT, TN-S UL 94 V-0 Mode of Protection L-N, N-PE Thermal Protection Yes Nominal Discharge Current Operating State/Fault (8/20 s) (I ) 20 kA n Indication Green Flag/No Green Flag Maximum Discharge Current Remote Contact Switching (8/20 s) (I ) Up to 50 kA max Capacity AC: 250 V/1 A, 125 V/1 A Protective Elements High Energy MOV DC: 48 V/0.5 A, 24 V/0.5 A, 12 V/0.5 A Response Time Remote Contact Conductor (L-N / N-PE t ) < 25 ns A 2 Cross Section (max) 1.5 mm (16 AWG) (Solid) Back-Up Fuse (max) 315 A / 250 A Gg Standards Passed* IEC 61643-11:2011 Number of Ports 1 EN 61643-11:2012 Mechanical & Environmental UL 1449, 4th edition E320116 Operating Temperature Product Dimensions Range (T ) -40 C to +80 C (-40 F to +185 F) a 3TE Module and Base H 90.0 mm (3.54) W 54.0 mm (2.13) Permissible Operating D 70.0 mm (2.76) Humidity (RH) 5% to 95% 1TE Replacement Module H 45.0 mm (1.77) W 18.0 mm (0.71) Altitude (max) 4,000 m (13,123 ft) D 57.2mm (2.25) Terminal Screw Torque) (M ) 4.5 Nm (39.9 lbf-in) max Package Dimensions Conductor Cross Section (max) 35 mm (2 AWG) (Solid, Stranded)/ 2 3TE Module and Base H 102.0 mm (4.01) W 64.0 mm (2.52) 25 mm (4 AWG) (Flexible) D 110.0 mm (4.33) Mounting 35 mm DIN Rail, EN60715 1TE Replacement Module H 102.0 mm (4.01) W 28.0 mm (1.10) Degree of Protection IP20 (built-in) D 110.0 mm (4.33) *SPD2-550-3P0-R and SPD2-550-M are UL Listed only Warranty Visit www.littelfuse.com/warranty for details. Disclaimer Notice Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for their own applications. Littelfuse products are not designed for, and may not be used in, all applications. Read complete Disclaimer Notice at www.littelfuse.com/product-disclaimer. Littelfuse.com/spd 2019 Littelfuse, Inc. 2 of 2 Rev: 1-A-061719 Nominal AC Voltage (50/60Hz) (U /U ) o n Maximum Continuous Operating AC Voltage (U ) c Nominal Discharge Current (8/20 s) (I ) n Maximum Discharge Current (8/20 s) (I ) max Voltage Protection Level (U ) p Short-Circuit AC Current Rating (I ) SCCR TOV Withstand 5 s (U ) T TOV 120 min (U ) / Mode T Maximum Continuous AC Operating Voltage (MCOV) Voltage Protection Rating (VPR) Nominal Discharge Current (8/20 s) (I ) n Short-Circuit Current Rating (SCCR)