FEATURES / BENEFITS Fully modular linear arrays of ultra high brightness LEDs POWERWHITE LINEAR MODULES Utilizes the latest 80+ lumen LUXEON Rebel LEDs for cool white, 70+ lumen for neutral white & 50+ lumen for warm white Choice of color temperatures & optical patterns >70% lumen maintenance 60,000 hours at max acceptable ambient temperature Lifesaver thermal protection OPERATING CONDITIONS APPLICATION Linear lighting Operating ambient temperature -30C to +55 ( 350mA) Accent lighting Requires constant current driver Flood lighting Compatible drivers include Dialight Lumidrives PWD60-35-70 Street & area lighting Runs 3-8 modules 350mA, 2-4 modules 700mA General illumination Additional heatsinking required when driven 700mA ORDERING INFORMATION MATERIALS / FINISH Six premium flux LUXEON Rebel LEDs per module Annodized cast aluminum heatsink Polycarbonate cover Dialight-Lumidrives optics Modular quick connect cables Module to module connector cable included Color (A) Optic (B) Connectors (sold separately) CW = Min 80 lumen v bin SP = 5 degree spot LML6-CON-CAB = Cool white 5300K Entry cable, driver to 1st module MD = 15 degree spot NW = Min 70 lumen s bin LML6-TER-CAB = WD = 25 degree wide Neutral white 3950K End plug (required) OV = 5X20 degree oval WW = Min 50 lumen n bin FR = 7 degree frosted spot 2 Warm white 2950K * Cables use 0.5mm AWG12 wires Dialight-Lumidrives Ltd. Dialight Corporation York House Wetherby Road Long Marston, York, YO26 7NH 1501 Route 34 South Farmingdale, NJ 07727 USA Tel: +44(0) 1904 739150 Fax: +44(0) 1904 737926 www.dialight.com Tel: (1) 732-919-3119 Fax: (1) 732-751-5778 www.dialight.com MDEXLUMPWM AMECHANICAL DIMENSIONS 11.7 x 1.498 x 0.585 (297.18mm x 38.05mm x 14.86mm) Mounting hole spacing = 3.22 (81.8mm) Max screw size 8 Total length for Z units connected end to end = (Z x 11.7) - ((Z-1) x 0.25) (inches) (Z x 297.2) - ((Z-1) x 6.35) (mm) Top View Side View Example: 2 units total length = 23.15 (588.01) ASSEMBLY INFORMATION 1) Position tab end of first powerwhite module by input wires/driver. (Do not connect power to entry cable before completing steps 2-6) 2) Remove cover from module (Do not remove mask). Modules may be screwed down onto surface by inserting two M6 or 8/32 flathead screws through screw holes. 3) Insert 6 pin prong from LML6-CON-CAB entry cable into 6 prong receptacle near tab end of first module. 4) Insert 4 pin prong from connector cable into notch end of module, insert 6 pin prong from connector cable into tab end of next module (repeat for each additional module). 5) Connector cable wires can be routed through interior of modules by placing them into interior wire holders. 6) Insert LML6-TER-CAB 4-pin terminal prong into notch end of last module in run INPUT WIRE CHART (required). 7) Replace covers and connect power to Color wire on To. or Connect to LM60-CON-CAB A50-LML6-CON-CAB entry cable on PWD60-35-70 White 1 Thermistor Wire 5 PHOTOMETRIC DATA White 2 Thermistor Wire 6 Wire 2 350mA TBD Red Driver + Wires 1 & 2 700mA IES 32 files available, consult factory Black Driver - Wire 3 Green Ground Green / Yellow Stripe Dialight-Lumidrives Ltd. Dialight Corporation York House Wetherby Road Long Marston, York, YO26 7NH 1501 Route 34 South Farmingdale, NJ 07727 USA Tel: +44(0) 1904 739150 Fax: +44(0) 1904 737926 www.dialight.com Tel: (1) 732-919-3119 Fax: (1) 732-751-5778 www.dialight.com MDEXLUMPWM A