Luminus Dynamic COB Two Channel CCT Tunable Datasheet CCT Tunable LED Spot Modules Features: Two channel cool and warm 90+ CRI MP-1616 XNOVA Cube LEDs on metal PC board 95 CRI typical with both channels powered on High lumen density for directional lighting Enables system beam angles from 10 to 40 degrees 4000K to 1800K CCT range for residential and hospitality lighting 6500K to 2700K CCT range for commercial lighting Robust design with LM-80 tested MP-1616 series LEDs Consistent white light <3 SDCM Specified hot performance and 100% factory tested at T =85C j Applications: Human centric lighting Hospitality / hotel / restaurant lighting Residential lighting Museum and high-end retail lighting Circadian lighting in hospitals, offices, or schools Public, commercial buildings Ceiling and wall mounted lights Multi-function space lighting Products Families CTM-9-XXXX-YY-36-TW01: Typical 7W per channel, 9.5mm LES CTM-14-XXXX-YY-36-TW01: Typical 15W per channel, 14.5mm LES CTM-18-XXXX-YY-36-TW01: Typical 20W per channel, 17.5mm LES CTM-22-XXXX-YY-36-TW01: Typical 32W per channel, 22mm LES o XXXX: CCT range (4018 = 4000K to 1800K) o YY: minimum CRI o 36 = 36V typical voltage o TW01 = standard configuration PDS-002951 www.luminus.com 1 Luminus, Inc. 1145 Sonora Court Sunnyvale, CA 94086 Luminus Dynamic COB Two Channel CCT Tunable Datasheet Technical Data Electrical data T =85C j Nominal Nominal Maximum Maximum forward input Nominal Maximum forward input current power voltage voltage current power per per per per per per Part number channel channel channel channel channel* channel* CTM-9-4018-90-36-TW01 200mA 7W 37V 39V 220mA 9W CTM-9-6527-90-36-TW01 200mA 7W 37V 39V 220mA 9W CTM-14-4018-90-36-TW01 400mA 15W 37V 39V 440mA 18W CTM-14-6527-90-36-TW01 400mA 15W 37V 39V 440mA 18W CTM-18-4018-90-36-TW01 550mA 20W 37V 39V 660mA 27W CTM-18-6527-90-36-TW01 550mA 20W 37V 39V 660mA 27W CTM-22-4018-90-36-TW01 875mA 32W 37V 39V 1100mA 45W CTM-22-6527-90-36-TW01 875mA 32W 37V 39V 1100mA 45W * Note that the maximum current and maximum power per channel also serve as guidelines for maximum current and maximum power for both channels combined. Luminaire thermal system capability and power derating curves on page 6 must be considered, and most 2 channel drivers will limit or should limit the combined maximum forward current of both channels per the values in the table above. Photometric Data T =85C and Nominal Forward Current: j CCT of Minimum Nominal CCT of Minimum Nominal CRI cool flux flux warm flux flux Part number (min) white (lumens) (lumens) white (lumens) (lumens) 635 375 405 CTM-9-4018-90-36-TW01 90 4000K 685 1800K CTM-9-6527-90-36-TW01 90 6500K 660 710 2700K 570 615 1300 785 825 CTM-14-4018-90-36-TW01 90 4000K 1370 1800K CTM-14-6527-90-36-TW01 90 6500K 1350 1420 2700K 1190 1255 1850 1120 1180 CTM-18-4018-90-36-TW01 90 4000K 1950 1800K CTM-18-6527-90-36-TW01 90 6500K 1900 2000 2700K 1700 1785 2945 1780 1875 CTM-22-4018-90-36-TW01 90 4000K 3100 1800K CTM-22-6527-90-36-TW01 90 6500K 3000 3160 2700K 2700 2840 PDS-002951 www.luminus.com 2 Luminus, Inc. 1145 Sonora Court Sunnyvale, CA 94086