Product Data Sheet 17XX STD Replace XX with 02 thru 12 for number of poles 1700 Series 30 Amps, 600 Volts AC/DC (Unprepared Wire) or 75 Amps, 600 Volts AC/DC when wired with crimp type ring, spade or fork terminal 5/8 Line to Line Spacing Wire Range (with unprepared wire): 10 - 18 AWG Copper See tables below for wire sizes. Electrical Ratings: 30A (unprepared wire) (Based on NEC Table 310-16, 75C columns) 75A (when wired with crimp type ring, spade or fork terminal) (Based on NEC Table 310-16, 75C columns) 600 Volts AC/DC (UL 1059 Class C, User Group - General Industrial) Short Circuit Current Rated for 10,000 Amps. Factory and Field Wiring Mechanical Ratings: Maximum insulator base temperature: 125C (257F) UL RTI Storage and transportation temperature range: -35C to 110C (-31F to 230F) Flammability rating of insulator base: UL 94 V-0 Use outside these ratings needs to be judged in the end-use application. Materials: Connector: Brass, nickel plated Insulator base: Glass-filled polycarbonate (thermoplastic) Screws: Brass, nickel plated, 10-32 Marking Strip: Vinyl (white) Marking strip anchor screws: Steel, zinc plated Agency Approvals: UL Recognized, UL 1059 Terminal Block Standard, File No. XCFR2.E62806 CSA Certified, CSA C22.2 No. 158, File No. LR19766 CE compliant to IEC 60947-7-1 RoHS Compliant Wire Approvals: Copper Wire Stranding Classes - Number of Strands Wire Size Torque Solid Class B Class C 10 AWG 20 in. lbs 1 7 19 12 20 in. lbs 1 7 19 14 20 in. lbs 1 7 19 16 20 in. lbs 1 7 19 18 20 in. lbs 1 7 19 Panel mountable: 10 fastener, torque to 25-30 in. lbs. Accessories: Cover: Clear PVC snap on cover, sized to fit and protect, CC17 XX (substitute XX for number of poles) Din Rail Adapter: Din R-1 Din Rail Channel: MN 35 (66 max, but can be cut to length) Printing Available on Marking Strip Consult factory for custom printed applications